Configuration Preparation

8. Should time be added to every polled device record received by the controller, or should time be appended to the data records only at some predetermined time interval?

9. Will time be broadcast to the polled devices?

10. Will your host application program be using device specific polling, for example to determine printer status?

Configuration Parameters

The controller is configured with default settings for data communication parameters at the factory. Table 3-4 lists the communication parameters that can be customized on the controller and their factory default values.

See Appendix B for a list of allowable values and Section 5, “Configuring the Controller," for an explanation of how to enter configuration parameters.

Parameters that are not disabled by entering an “N“ for No are disabled by leaving the parameter field blank on the Supervisory CRT. In Table 3-4, *--" indicates a blank field.

© 1987 INTERMEC Corporation Page 3-27

Page 72 read from a scan by OCR; it may hold reading errors

DESIGNING A 9154 SYSTEM

Table 3-4

Default and Configured Communication Parameters

Default Configured Parameter Value: Value: Supervisory CRT Clear Screen Sequence SUB Cursor Position Sequence ESC=<SP><SP> Row Offset 2 Column Offset 3 Host Line Parameters Line Speed 9600 Parity Even Data Bits 7 Stop Bits 1 Multi-Drop Line Parameters Line Speed 9600 Address (of Multi-Drop port) p To Host Transmission Parameters Number of Records per Block 1 Record Separator CR Header - SOM STX EOM ETX RES STX ZCR AFF STX YCR NEG STXZCR Error Message SOM STX Error Message EOM ETX Transparency Check (Yes or No) No Data Wait Mode (Yes or No) No

Page 3-28

© 1987 INTERMEC Corporation

Page 73 read from a scan by OCR; it may hold reading errors

Configuration Preparation

Table 3-4 (cont.) Default and Configured Communication Parameters

Default Configured Parameter Value: Value: From Host Transmission Parameters POL ENQ SEL BEL AFF ACK NEG NAK DLE DLE SOM STX EOM ETX Record Separator CR Delay (0-99) x 10 ms Oms Timeout (0-60) x 1 sec 60 sec XON/XOFF (Yes or No) No LRC Enabled (Yes or No) No Real Time Clock Parameters Date 87/01/01 Time 00:00 Time Append Enable Time Append (Yes or No) No Interval (0-99) x minute 1 minute Record Day Rollover (Yes or No) No

© 1987 INTERMEC Corporation

Page 3-29

Page 74 read from a scan by OCR; it may hold reading errors

DESIGNING A 9154 SYSTEM

Table 3-4 (cont.) Default and Configured Communication Parameters

Default Configured Parameter Value: Value: Time Broadcast

Enable Time

Broadcast

(Yes or No) No Interval (0-99)

x minute 1 minute Preamble HT Postamblie - Display Format 24 Include YY/MM/DD

(Yes or No) No

Page 3-30 © 1987 INTERMEC Corporation

Page 75 read from a scan by OCR; it may hold reading errors

SECTION 4

INSTALLING HARDWARE

INSTALLATION OVERVIEW

INSTALLING THE 9154 CONTROLLER Unpacking Standard Items Required Tools Mounting Connecting the Controller to Ground Power Sources

CONNECTING THE SUPERVISORY CRT TO THE 9154 Configuration Controller to CRT Interface Connecting the Controller to the CRT

CONNECTING THE HOST COMPUTER TO THE 9154 Choosing an Appropriate Interface RS-232 RS-422/485 Modem Current Loop

CONNECTING THE 9154 TO POLLED DEVICES Compatible Readers and Printers Designing a Multi-Drop Cable Layout Multi-Drop Cables Installing the Multi-Drop Cabling System Segment-By-Segment Main Trunk Cable Installation Laying the Main Trunk First Connection to Specific Readers

VERIFYING SYSTEM INSTALLATION

© 1987 INTERMEC Corporation Page 4-1

Page 76 read from a scan by OCR; it may hold reading errors

INSTALLING HARDWARE

INSTALLATION OVERVIEW

This section describes how to physically set up the 9154 Controller and connect it to polled devices, Supervisory CRT and the host. The installation of the controller should be approached in a step-by-step fashion. For information about planning the layout of a system installation, see Section 3, "Designing a 9154 System."

The major tasks required for installing a controller system are:

Mount the Controller.

Connect a Ground Cable.

Connect a Power Supply.

Connect a Supervisory CRT.

Choose a Controller to Host Interface Type.

Install the Host Interface.

Connect Multi-Drop Cabling from the Controller to the Devices.

NOORON =

Although there are several ways to accomplish some of the tasks, they are all necessary for installing a controller system. The remainder of Section 4 tells you how to complete the seven tasks listed above.

Page 4-2 © 1987 INTERMEC Corporation

Page 77 read from a scan by OCR; it may hold reading errors

Installing the 9154 Controller

INSTALLING THE 9154 CONTROLLER

Unpacking

The controller is thoroughly tested and inspected before shipment. When you receive the unit, remove it from its shipping container and verify the contents against the checklist in the next section, “Standard Items." Inspect for shipping damage. If the shipping container shows external damage and the unit does not operate properly, file a claim with the shipping firm immediately. The customer is responsible for all claims against the carrier. (See INTERMEC Terms of Sale.)

Keep the packing material and container should later repacking and shipment be necessary. Damage caused by improper repacking is not covered by the warranty. Figure 4-1 shows how the controller is packed, and how should be replaced in its container if it is returned or stored.

INTERMEC Supplied Power Supply

9154 Multi-Drop Line Controller

9154 Multi-Drop Line Controller System Manual

Figure 4-1 Unpacking the Controller

© 1987 INTERMEC Corporation Page 4-3

Page 78 read from a scan by OCR; it may hold reading errors

INSTALLING HARDWARE

Standard Items The following items are shipped with the controller:

* 9154 Multi-Drop Line Controller with four rubber feet

° List of Authorized Service Representatives

* 9154 Multi-Drop Line Controller System Manual, INTERMEC Part No. 048517

+, Power supply

Required Tools The following tools will be needed to install the controller and connecting cabling to the host and polled devices:

. Screwdriver (if the controller is mounted with screws) CRT (to configure the controller)

* Wrench (7/16 inch, to tighten the grounding nut)

« Small slot screwdriver (to fasten the cabling connectors)

The following additional tools will be required to make cables:

* Wire strippers

+ Wire cutters

¢, Soldering iron

*, Solder and flux

¢, Vise for holding connectors during assembly . Heat gun and heat shrink sleeving o Cable ties

1/4 inch diameter ring lug (18-20 AWG)

+, Crimp tool for ring lug

Note: This manual does not describe how to make Multi-Drop cabling, although wiring diagrams for the necessary connections are provided.

Page 4-4 © 1987 INTERMEC Corporation

Page 79 read from a scan by OCR; it may hold reading errors

Installing the 9154 Controller

Mounting

Depending on the environment in which the controller will be used and the specific needs of the operator, the controller may be mounted in one of two ways, either resting on a surface, or fastened to it. Both mounting methods are satisfactory for long-term controller operation. Instructions for each method follow.

Placing Controller on a Flat Surface: Follow these steps to mount the controller on a flat surface:

1. Select a flat horizontal surface like a table top. Ensure there is easy access to connectors and that the status lights are visible.

2. Remove the adhesive backing from the four rubber feet. Press a foot into the recess located in each of the four corners on the bottom of the controller.

3. Position the controller on the mounting surface. Ensure that the controller is not located too close to a surface edge where it could be pulled or knocked off.

4. Proceed to “Connecting the Controller to Ground.”

Mounting the Controller with Screws: Figure 4-2 illustrates mounting using screws.

Note: 3/16 of an inch is the maximum screw thread diameter that will fit through the mounting holes on the controller.

1. Locate a flat surface on which to mount the controller. The surface may be vertical, horizontal, or any incline in between. Ensure there is easy access to connectors and that the status lights are visible.

2. Remove the adhesive backing from the four rubber feet. Press a foot into the recess located in each of the four corners on the bottom of the controiler.

© 1987 INTERMEC Corporation Page 4-5

Page 80 read from a scan by OCR; it may hold reading errors

INSTALLING HARDWARE

3. Use the mounting template (shown in Figure 4-3) to locate and drill screw holes. Do not drill through the controller mounting holes.

4. Place the controller over the drilled holes on the mounting surface.

5. Install a screw through each of the two mounting holes on the top of the controller into the holes on the surface.

6. Proceed to “Connecting the Controller to Ground.”

Mounting Screws (not included)

Drilled Hole

Figure 4-2 Mounting the Controller with Screws

Page 4-6 © 1987 INTERMEC Corporation