The text of a manual · part 8 of 12
EasyCoder 7421 Printer User's Manual: Chapter 4 - Troubleshooting
Pages 59 to 66 of 100, from EasyCoder 7421 Printer User's Manual
The original document is the PDF (1.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 7421
Page 59
4 Troubleshooting
Page 60
Page 61
This chapter provides some hints for troubleshooting error messages that the printer sends to the host and problems you may experience with the printer.
Troubleshooting Checklist You may have printer operation, print quality, or printer communications problems at some time during the life of your printer. It is easy to fix most of the errors and consequently not delay operation of the printer for very long.
To troubleshoot your printer 1. First try cleaning the printer components and checking all of the connections. See Chapter 3, “Maintaining the Printer,” for details. 2. If cleaning the printer and checking the connections does not solve the problem, use the following tables to locate the symptom. Follow the solution in the table to fix your problem. If you receive an error message on your PC, refer to your IPL Programming Reference Manual for a complete list of error messages and their solutions. If the problem persists, contact your Intermec Customer Service Representative: In the U.S. In Canada
1.800.755.5505 1.800.688.7043
If you are an international customer, contact your local Intermec representative.
4-3
Page 62
Printer Operation Problems If your printer is not operating correctly, try locating the problem in the table below.
Symptom
Possible Causes
Solution
No power or loss of power.
You have damaged or disconnected the power cable.
Make sure you have plugged the power cable into both the printer and a power source. Replace the cable if damaged.
The Power light flashes red and printing stops.
Printhead has overheated.
Let the printer cool down. It will resume printing on its own.
Test configuration label does not print.
You have incorrectly loaded media.
Try reloading the media. For help, see “Loading Media” in the 7421 Printer Setup Guide.
Printing stops and the Power light glows orange.
Media fault.
Possible problem with the label gap sensor. Adjust the label sensor. For help, see “Adjusting the Label Gap Sensor” in Chapter 2.
Label jam.
Remove any jammed labels from the printer and clean the printhead. For help, see “Cleaning the Printhead” in Chapter 3.
The printhead is up.
Make sure the printhead is down. Cycle printer power and press the Feed/Pause button to resume printing.
You have incorrectly loaded the media.
Try reloading the media. For help, see “Loading Media” in the 7421 Printer Setup Guide.
Media loaded incorrectly.
If you are using direct thermal media, make sure the roll is loaded with the thermal side facing up.
Printer appears to be working but nothing prints.
If you are using thermal transfer media, you must use a thermal transfer ribbon. 4-4
Page 63
Print Quality Problems If your labels are not being printed properly, check the following table to locate the symptom and correct the problem.
Symptom
Possible Causes
Solution
Blotches printing on labels.
Dirty printhead.
Clean the printhead. For help, see “Cleaning the Printhead” in Chapter 3.
Printing is too light or too dark.
Poor quality label or ribbon stock.
Use only Intermec label and ribbon stock to ensure superior print quality and product performance.
Incorrect media sensitivity setting.
Change sensitivity setting to match the type of media you are using. If you set the sensitivity setting correctly, try changing the dark adjust. For help, see your PrintSet online help or the IPL Programming Reference Manual.
Labels are not stopping at the right point for removal.
You have not set the label rest point command correctly.
Adjust the label rest point. For help, see your PrintSet online help or the IPL Programming Reference Manual.
Print quality is poor.
Printhead is dirty.
Clean the printhead. For help, see “Cleaning the Printhead” in Chapter 3.
Poor quality label or ribbon stock.
Use only Intermec label and ribbon stock to ensure superior print quality and product performance.
Ribbon wrinkling.
Check to make sure that you installed the ribbon correctly. For help, see “Loading Thermal Transfer Media and Ribbon” in the 7421 Printer Setup Guide.
4-5
Page 64
Communication Problems If your printer is not receiving downloaded data, try the solutions in this table.
Symptom
Possible Causes
Solution
Printer does not communicate with the host.
Incorrect communications parameters.
Use PrintSet to make sure that you have the correct communications parameters set (such as baud rate).
Damaged or incorrect I/O cable.
Check the connections at both ends or replace the cable. See Appendix B for cable information.
Using Data Line Print Mode Use Data Line Print mode to troubleshoot communications between the printer and the host, and to test the operation of the printer. When the printer is in Data Line Print mode, it prints out all downloaded data with the hexadecimal equivalent directly underneath it.
To enter Data Line Print mode 1. Turn the On/Off switch to the off position. 2. Press down and hold the Feed/Pause button while turning on the printer. The hardware configuration test label prints out and the firmware program and version number are sent to the host. You are now in Data Line Print mode. 3. Send a few characters down from the host. The printer prints out your data with the hexadecimal equivalent directly underneath it.
4-6
Page 65
4. Hold the Feed/Pause button down to momentarily suspend the test. The printer prints a software configuration test label. 5. If you press the Feed/Pause button again, the pitch label prints.
To exit Data Line Print mode 1. Turn the printer power off. 2. Turn the printer power back on.
Preventing Data Loss Several problems can cause data loss or communications problems on the printer. Data loss can result in printing errors or missing field data. Hardware handshaking involves the use of a hardware wire. Software handshaking involves a two-way datalink between the devices. The two devices communicate with each other without losing data through the use of handshaking. The printer sends both forms of handshaking simultaneously when the printer’s input buffer is full. Any loss of data can cause printing errors or missing data. Hardware handshaking uses pin 6 or pin 9 of the RS-232 interface to control data flow. When the printer is using Intermec Standard protocol, it holds pins 6 and 9 high when the printer is ready to receive data. For help on understanding printer protocol, see Appendix B, “Communications Reference.” The printer holds pins 6 and 9 low when the printer is in one of these conditions: • Buffer full • Ribbon fault • No label stock • Label at peel-off bar
4-7
Page 66
Your printer uses XON/XOFF protocol for software handshaking. When the input buffer is full, the printer transmits an XOFF character. This action alerts the host to the fact that the printer buffer is full and cannot receive any more data. When the printer is ready to receive more data, it sends the XON character. To check for communications problems 1. Check the cabling from the printer to the host system. 2. Check the interfacing of the devices that are communicating with the printer. 3. Check the printer for proper electrical operation of the I/O port. 4. Test to see that the host system is not overrunning the printer’s input buffer. 5. Check to see that the data string being sent to the printer contains the correct information.
Resetting the Printer to Factory Defaults Use memory reset if you want to return the printer to its default configuration. To reset the printer to factory defaults 1. Turn off the printer. 2. Lift the printhead and remove all label stock from the paper path. 3. Turn the printer on while holding down the Feed/Pause button. 4. When the print mechanism starts to move, release the Feed/Pause button and press it again. The Power light should now be flashing red. 5. Press and hold the Feed/Pause button down for 8 seconds or until the Power light stops flashing. The printer resets all parameters to their factory default settings.
4 -8