The text of a manual · part 10 of 21
6820 Series 80-Column Printer User's Manual, 6822 Configuration: Control Code Definitions, pages 76 to 84
Pages 76 to 84 of 171, from 6820 Series 80-Column Printer User's Manual, 6822 Configuration
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 6822
Page 76
Chapter 4, Control Code Definitions above 128, the character code from the selected SBCS is printed. NFT00950.MOD (BIG 5 DBCS) does not allow the MBCS mode. For this character set, only control codes from 0-31 are treated as single byte characters when they are not proceeded by a lead-in byte. All escape sequence character strings are treated as SBCS.
Select National Character Set By default, code page 0 is selected by the printer at reset. Use the following escape sequence to select international character support. Escape sequence codes can only be used for code page 0. All other code pages use direct character code mapping to select the appropriate font for rendering. Format Decimal
Hex
ASCII
27 82 n
1B 52 n
ESC “R” n n is 0-14 and is the country code, as shown in the International Character Sets table on the next page. The default value for n is zero (USA). A full 256 character set is not provided for these sets. There are 64 international characters stored in ROM, 32 in Roman and 32 in Italic. They are stored as codes 0-31 and 128-255. These are normally not accessible. The ESC “R” command makes these codes available, but only 12 characters at a time. These 12 are available in these positions of the ASCII character table: 35, 36, 64, 91, 92, 93, 94, 96, 123, 124, 125, and 126, as shown in the International Character Sets table. International Character Sets Country
Country Number
35
36
64
91
92
93
94
96
123
124
125
126
USA
0
#
$
@
[
\
]
^
‘
{
|
}
~
France
1
#
$
à
º
ç
§
^
‘
é
ù
è
¨
Germany
2
#
$
§
Ä
Ö
Ü
^
‘
ä
ö
ü b
England (UK)
3
£
$
@
[
\
]
^
‘
{
|
}
~
Denmark 1
4
#
$
@
Æ
Ø
Å
^
‘
æ
ø
å
~
Sweden
5
#
¤
É
Ä
Ö
Å
Ü
é
ä
Ö
å
ü
Italy
6
#
$
@
º
\
é
^
ù
à
è
ì
62
6820 Series 80-Column Printer User’s Manual
Page 77
Chapter 4, Control Code Definitions
International Character Sets (continued) Country
Country Number
35
36
64
91
92
93
94
96
123
124
125
126
Spain 1
7
P
$
@
¡
Ñ
¿
^
‘
¨
ñ
}
~
Japan
8
#
$
@
[
¥
]
^
‘
{
|
}
~
Norway
9
#
¤
É
Æ
Ø
Å
Ü
é
æ
ø
å
ü
Denmark 2
10
#
$
É
Æ
Ø
Å
Ü
é
æ
ø
å
ü
Spain 2
11
#
$
á
¡
Ñ
¿
é
‘
í
ñ
ó
ú
Latin America
12
#
$
á
¡
Ñ
¿
é
ü
í
ñ
ó
ú
Hebrew
13
Hebrew fonts are available in the supplied font files. See “Hebrew Character Fonts” below.
Greece
14
Greek fonts are available in the supplied font files. See the “Greek Character Set” on page 64.
Hebrew Character Set Hebrew characters represented by decimal values 38 and 65 through 90 are represented by the following 7x7 font descriptions. *.*.*.. ....*.* *.*.*.* *.*.*.* ....*.* *.*.*.* *.*.*.* *..*.*. ....*.. ......* .....*. .....*. ......* ...*... .*...*. *..*..* ....*.. ....*.* .....*. *....*. ......* ...*... *....*. *..*..* ....*.. ...*..* .....*. *....*. ......* ...*... *....*. *.....* *.*.*.* ..*...* .....*. *....*. ......* ...*... *....*. *....*. ....... ....... ....... ....... ....... ....... ....... *.*.*.. ....... ....... ....... ....... ....... ....... ....... ....... 65
66
67
68
69
70
71
72
....... ....... ....... *...... ....... ....... ....... ....... ....*.* ..*.*.* *.*.*.. *.*.*.* *.*.*.* *..*... ....*.* ....*.* ......* ......* ......* ......* *.....* .*.*.*. ......* ......* ......* ......* ......* .....*. *.....* ..*...* ......* ......* ....... ......* ......* ....*.. *.....* .*....* ......* ......* ....... ......* *.*.*.. .*.*... *.*.*.* *...*.* ......* ..*.*.* ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... 73
74
75
76
77
78
79
80
....... ....... ....... ....... ....... ....... ....... ....... *.*.*.* *.....* *.*.*.* *.*.*.. *....*. *.....* *.*.*.* *.*.*.* ..*...* *.....* *.....* *.....* .*..*.. .*...*. ......* ......* .*....* .*...*. *.*...* *.*...* ..*.*.. ...*... .*....* ......* *....*. ..*.*.. ......* ......* ......* .....*. *.*.*.* ......* 6820 Series 80-Column Printer User’s Manual
63
Page 78
Chapter 4, Control Code Definitions *.*.*.. *.*.*.* ......* *.*.*.. ......* *.*.*.* *...... ......* ....... ....... ......* ....... ......* ....... *...... ....... ....... ....... ....... ....... ....... ....... ....... ....... 81
82
83
84
85
86
87
88
.....*. ....... ....... *..*..* ..*.*.* *.....* *..*..* ..*...* .*....* *..*..* ..*...* .*.*.*. *.*..*. ..*...* *....*. *...*.. *.*...* *.....* ....... ....... ....... ....... ....... ....... 89
90
91
Greek Character Set Greek Character Set Dec
Hex
Chr
Dec
Hex
Chr
Dec
Hex
Chr
97
61
A
105
69
I
113
71
P
98
62
B
106
6a
K
114
72
S
99
63
G
107
6b
L
115
73
T
100
64
D
108
6c
M
116
74
Y
101
65
E
109
6d
N
117
75
F
102
66
Z
110
6e
X
118
76
X
103
67
H
111
6f
O
119
77
Y
104
68 q
112
70
P
120
78
W
The selected set stays in effect until the printer is reset and receives a Master Reset command, or a new international character set is selected. Note: This function is only used with the default character set
64
6820 Series 80-Column Printer User’s Manual
Page 79
Chapter 4, Control Code Definitions
User Defined Characters This section describes user-defined characters and how characters are copied into printer memory. Note: RAM-based definition or redefinition of standard characters is only useful when the default SBCS code page is selected. There is no method to redefine characters in the other code pages, since unique code pages can be created and loaded into the printer memory.
Copy ROM to RAM The characters in ROM are copied into RAM, so a complete user-defined character set is created by editing selected characters. This ensures that all characters are defined when a user-defined character set is selected. This eliminates the need to cancel the selection when printing defined characters. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 58 0 0 0
1B 3A 00 00 00
ESC “.” NUL NUL NUL
Define User Defined Characters Characters are redefined by the user in the currently selected mode. However, they can only be used in draft mode. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 38 0 k1 k2 s1 d1 ... d11
1B 26 00 k1 k2 s1 d1 ... d11
ESC “&” k1 k2 s1 d1.....d11
6820 Series 80-Column Printer User’s Manual
65
Page 80
Chapter 4, Control Code Definitions k1 is the character code of the first character to redefine, k2 is the character code of the last character to redefine (any character between 0-255 can be redefined), and (k1 could equal k2, if only one character is defined). For each character defined, you must supply 12 bytes of data. • s1 is the first byte that describes the character format
•
Bits 0-3 represent the end position in the grid
•
Bits 4-6 represent the start position in the grid
•
Bit 7 determines whether the character uses the top eight pins or the bottom eight pins of the printhead. If bit 7 = 0, the top eight pins are used. If bit 7 = 1, the bottom eight pins are used. The start and end positions are ignored during character imaging, but must be accurate to redefine the character code. d1...d11 is the data that comprises the dot image pattern of the defined character.
When printable code expansion is enabled with ESC I, the Printable Code Area Expansion function, and the user-defined character set is selected with ESC “%” (1), the Select User-Defined Set function, then the codes (less than 20h and greater than 7Fh) can be defined for use and are printable. When printable code expansion is enabled with the Enable Printing of Codes 128-159 function, and the user-defined character set is selected with the Select User-Defined Set function, then codes (between 80h and 9Fh) can be defined for use and are printable. For a list of these characters, refer to the “Printable Code Expansion Characters” on page 68.
Select User-Defined Character Set A user-defined character set can be selected, after the Define User-Defined Characters function is used to define the character set. Note: This function is only useful with the default SBCS.
66
6820 Series 80-Column Printer User’s Manual
Page 81
Chapter 4, Control Code Definitions
Format Decimal
Hex
ASCII
27 37 1
1B 25 01
ESC “%” (1)
Select Default Character Set If the Select User-Defined Set function was previously set, this function switches back to the default character set. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 37 0
1B 25 00
ESC “%” (0)
Enable Printing of Codes 128-159 All codes (128-159) are treated as printable characters, rather than control codes, with this function. This allows the use of these characters for user-defined characters. A user-defined set must be selected, using the Select User-Defined Set function, before these characters can print. Factory default disables printing of these codes. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 54
1B 36
ESC “6”
6820 Series 80-Column Printer User’s Manual
67
Page 82
Chapter 4, Control Code Definitions
Disable Printing of Codes 128-159 Disables the printing of codes 128-159. By default, these codes are disabled. Format Decimal
Hex
ASCII
27 55
1B 37
ESC “7”
Expand Printable Code Area This function allows certain ASCII codes (00h to 1Fh) and codes (80h to 9Fh) to print when the variable n is set to the value of 1. This allows the use of these codes for user-defined characters. If n = 0, the function returns these two ranges of characters to non-printable control codes. A user-defined character set must be selected by ESC “%” (1), the Enable Printing of Codes 128-159 function, before these codes can print. In both ranges, only the following codes can redefine as printable characters. Codes not listed, within the range (00h-1Fh), print as standard control codes. Codes not listed, within the range (80h-9Fh), are converted to a control code in the range of (00h-1Fh), by subtraction of 80h. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 73 n
1B 49 n
ESC “I” n
Printable Code Expansion Characters Hex
ASCII
00
NUL
11
DC1
80 none
91 none
01
SOH
15
NAK
81 none
95 none
02
STX
16
SYN
82 none
96 none
03
ETX
17
ETB
83 none
97 none
04
EOT
1C
FS
84 none
9C none
68
Hex
ASCII
Hex
ASCII
Hex
ASCII
6820 Series 80-Column Printer User’s Manual
Page 83
Chapter 4, Control Code Definitions
Printable Code Expansion Characters (continued) Hex
ASCII
Hex
ASCII
Hex
ASCII
Hex
ASCII
05
ENQ
1D
GS
85 none
9D none
06
ACK
1E
RS
86 none
9E none
10
DLE
1F
US
90 none
9F none
Enable Printing of Character Graphics Enables the printing of character graphics, until disabled with the Disable Printing of Character Graphics function. Note: This function is only useful with the default SBCS.
Format Decimal
Hex
ASCII
27 116 1
1B 74 01
ESC “t” (1)
For character values from 0 to 31 (00h-1Fh): •
When the default SBCS code page is selected, the FX-86e IBM character graphics symbol set is printed.
•
When other SBCS code pages are selected, the codes (00h-1Fh), listed above in the Printable Code Expansion Characters table are printed.
For character values from 32 to 126 (20h-7Eh): •
When the default SBCS code page is selected, the selected international character set is printed.
•
When other SBCS code pages are selected, the international character set selection is not in effect.
For the character value 127 (7Fh): •
When the default SBCS code page is selected, a space is printed
•
When other SBCS code pages are selected, the character associated with the code page is printed.
6820 Series 80-Column Printer User’s Manual
69
Page 84
Chapter 4, Control Code Definitions
For character values from 128 to 255 (80h-FFh), the FX-86e Epson Character Graphics set is printed.
Disable Printing of Character Graphics Disables the printing of character graphics. Factory default disables this function. Format Decimal
Hex
ASCII
27 116 0
1B 74 00
ESC “t” (0)
Enable Printing of Character Graphics This function allows printing of character graphics from the currently selected SBCS code page, by sending a graphics string to the printer. The values of the graphics data bytes can range between 0-255. Format Decimal
Hex
ASCII
27 43 n d1 ... dn
1B 2B n d1 ... dn
ESC “+” n d1 ... dn n is the length of the character graphic string and d1 ... dn are the character graphics data stream. The number of data bytes must be equal to the value of the variable n. The range of values (for the characters in each graphics data byte): 0-255. For character values from 0 to 31 (00h-1Fh): •
When the default SBCS code page is selected, the FX-86e IBM character graphics symbol set is printed.
•
When other SBCS code pages are selected, currently selected single byte code page character graphics are printed.
For character values from 32 to 126 (20h-7Eh): •
70
When the default SBCS code page is selected, the selected international character set is printed.
6820 Series 80-Column Printer User’s Manual