For the Intermec 6400

Page 149

SECTION 5

Customizing Your Configuration

"

"

Fixed Length 4 [Session 1].UPC.Fix Length 4 Session 2.UPC.Fix Length 4 [Session 1].EAN.Fix Length 4 Session 2.EAN.Fix Length 4 [Session 1].Code 128.Fix Length 4 Session 2.Code 128.Fix Length 4 [Session 1].Code 39.Fix Length 4 Session 2.Code 39.Fix Length 4 [Session 1].Codabar.Fix Length 4 Session 2.Codabar.Fix Length 4 [Session 1].ABC Codabar.Fix Length 4 Session 2.ABC Codabar.Fix Length 4 [Session 1].Str 2of5.Fix Length 4 Session 2.Str 2of5.Fix Length 4 [Session 1].Int 2of5.Fix Length 4 Session 2.Int 2of5.Fix Length 4 [Session 1].CI 2of5.Fix Length 4 Session 2.CI 2of5.Fix Length 4 [Session 1].Code 11.Fix Length 4 Session 2.Code 11.Fix Length 4 [Session 1].Code 93.Fix Length 4 Session 2.Code 93.Fix Length 4 [Session 1].Plessey.Fix Length 4 Session 2.Plessey.Fix Length 4 Numeric, minimum = 0 [0], maximum = 99 [0] Maximum Length [Session 1].UPC.Max Length Session 2.UPC.Max Length [Session 1].EAN.Max Length Session 2.EAN.Max Length [Session 1].Code 128.Max Length Session 2.Code 128.Max Length [Session 1].Code 39.Max Length Session 2.Code 39.Max Length [Session 1].Codabar.Max Length Session 2.Codabar.Max Length [Session 1].ABC Codabar.Max Length Session 2.ABC Codabar.Max Length [Session 1].Str 2of5.Max Length Session 2.Str 2of5.Max Length [Session 1].Int 2of5.Max Length Session 2.Int 2of5.Max Length [Session 1].CI 2of5.Max Length Session 2.CI 2of5.Max Length [Session 1].Code 11.Max Length Session 2.Code 11.Max Length [Session 1].Code 93.Max Length Session 2.Code 93.Max Length [Session 1].Plessey.Max Length Session 2.Plessey.Max Length Numeric, minimum = 0 [0], maximum = 99 [0]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-21

Page 150

Customizing Your Configuration

"

Minimum Length [Session 1].UPC.Min Length Session 2.UPC.Min Length [Session 1].EAN.Min Length Session 2.EAN.Min Length [Session 1].Code 128.Min Length Session 2.Code 128.Min Length [Session 1].Code 39.Min Length Session 2.Code 39.Min Length [Session 1].Codabar.Min Length Session 2.Codabar.Min Length [Session 1].ABC Codabar.Min Length Session 2.ABC Codabar.Min Length [Session 1].Str 2of5.Min Length Session 2.Str 2of5.Min Length [Session 1].Int 2of5.Min Length Session 2.Int 2of5.Min Length [Session 1].CI 2of5.Min Length Session 2.CI 2of5.Min Length [Session 1].Code 11.Min Length Session 2.Code 11.Min Length [Session 1].Code 93.Min Length Session 2.Code 93.Min Length [Session 1].Plessey.Min Length Session 2.Plessey.Min Length Numeric, minimum = 0 [0], maximum = 99 [0]

UPC Options "

"

"

"

"

5-22

Add-On 2 [Session 1].UPC.Add-On 2 Session 2.UPC.Add-On 2 Enabled [Disabled] Add-On 5 [Session 1].UPC.Add-On 5 Session 2.UPC.Add-On 5 Enabled [Disabled] Expand E to A [Session 1].UPC.Expand E to A Session 2.UPC.Expand E to A Enabled [Disabled] System 0 UPCE [Session 1].UPC.Sys 0 UPCE Session 2.UPC.Sys 0 UPCE Enabled [Disabled] System 1 UPCE (not supported on the 6400) [Session 1].UPC.Sys 1 UPCE Session 2.UPC.Sys 1 UPCE Enabled [Disabled]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

SECTION 5

Page 151

SECTION 5

Customizing Your Configuration

EAN Options "

"

"

Add-On 2 [Session 1].EAN.Add-On 2 Session 2.EAN.Add-On 2 Enabled [Disabled] Add-On 5 [Session 1].EAN.Add-On 5 Session 2.EAN.Add-On 5 Enabled [Disabled] Expand 8 to 13 [Session 1].EAN.Expand 8to13 Session 2.EAN.Expand 8to13 Enabled [Disabled]

Code 39 Options "

"

"

"

"

"

"

Auto-Encoded [Session 1].Code 39.Auto-Encoded Session 2.Code 39.Auto-Encoded Enabled [Disabled] Check Digit [Session 1].Code 39.Chk Digit Session 2.Code 39.Chk Digit Enabled [Disabled] Data Decode [Session 1].Code 39.Data decode Session 2.Code 39.Data decode Enabled [Disabled] Element Decode [Session 1].Code 39.Element decod Session 2.Code 39.Element decod Enabled [Disabled] Encoded [Session 1].Code 39.Encoded Session 2.Code 39.Encoded Enabled [Disabled] Extended [Session 1].Code 39.Extended Session 2.Code 39.Extended Enabled [Disabled] Full ASCII [Session 1].Code 39.Full ASCII Session 2.Code 39.Full ASCII Enabled [Disabled] TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-23

Page 152

Customizing Your Configuration

"

"

Quiet Zone [Session 1].Code 39.Quiet zone Session 2.Code 39.Quiet zone Enabled [Disabled] START Decode [Session 1].Code 39.START decode Session 2.Code 39.START decode Enabled [Disabled]

Interleaved 2 of 5 Option "

Interleaved 2 of 5 Chk Digit [Session 1].Int 2of5.Chk Digit Session 2.Int 2of5.Chk Digit Enabled [Disabled]

Code 11 Options "

"

Check Digit 1 (not supported on the 6400) [Session 1].Code 11.Chk Dig 1 Session 2.Code 11.Chk Dig 1 Enabled [Disabled] Check Digit 2 (not supported on the 6400) [Session 1].Code 11.Chk Dig 2 Session 2.Code 11.Chk Dig 2 Enabled [Disabled]

Plessey Options "

"

"

5-24

Allow Alpha [Session 1].Plessey.Allow Alpha Session 2.Plessey.Allow Alpha Enabled [Disabled] MOD 10 Check [Session 1].Plessey.MOD10 Chk Session 2.Plessey.MOD10 Chk Enabled [Disabled] MOD 11 Check [Session 1].Plessey.MOD11 Chk Session 2.Plessey.MOD11 Chk Enabled [Disabled]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

SECTION 5

Page 153

SECTION 5

Customizing Your Configuration

Code 128 Options "

"

"

UCC/EAN [Session 1].Code 128.UCC/EAN Session 2.Code 128.UCC/EAN Enabled [Disabled] No UCC Type [Session 1].Code 128.NO UCC Type Session 2.Code 128.NO UCC Type Enabled [Disabled] UCC F1 Value [Session 1].UPC.UCC F1 Value Session 2.UPC.UCC F1 Value [Session 1].EAN.UCC F1 Value Session 2.EAN.UCC F1 Value [Session 1].Code 128.UCC F1 Value Session 2.Code 128.UCC F1 Value [Session 1].Code 39.UCC F1 Value Session 2.Code 39.UCC F1 Value [Session 1].Codabar.UCC F1 Value Session 2.Codabar.UCC F1 Value [Session 1].ABC Codabar.UCC F1 Value Session 2.ABC Codabar.UCC F1 Value [Session 1].Str 2of5.UCC F1 Value Session 2.Str 2of5.UCC F1 Value [Session 1].Int 2of5.UCC F1 Value Session 2.Int 2of5.UCC F1 Value [Session 1].CI 2of5.UCC F1 Value Session 2.CI 2of5.UCC F1 Value [Session 1].Code 11.UCC F1 Value Session 2.Code 11.UCC F1 Value [Session 1].Code 93.UCC F1 Value Session 2.Code 93.UCC F1 Value [Session 1].Plessey.UCC F1 Value Session 2.Plessey.UCC F1 Value Numeric, minimum = 0 [0], maximum = 255

VT/ANSI Protocol Options "

"

"

AnswerBack [Session 1].AnswerBack Session 2.AnswerBack String, minimum length=0, maximum length = 30 [null string, not defined] Auto Enter Scan [Session 1].Auto Entr Scn Session 2.Auto Entr Scn Enabled [Disabled] Auto Tab Scan [Session 1].Auto Tab Scan Session 2.Auto Tab Scan Enabled [Disabled] TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-25

Page 154

Customizing Your Configuration

"

"

"

"

"

"

"

"

"

"

5-26

SECTION 5

CR to CRLF [Session 1].CR to CRLF Session 2.CR to CRLF Enabled [Disabled] DEL to BS [Session 1].DEL to BS Session 2.DEL to BS Enabled [Disabled] Discrete Bells (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].DiscreteBells Session 2.DiscreteBells Enabled [Disabled] Extended Commands [Session 1].Extended Cmds Session 2.Extended Cmds Enabled [Disabled] Host View Columns [Session 1].Host View Cols Session 2.Host View Cols Numeric, minimum = 1, maximum = 255 [24] Host View Rows [Session 1].Host View Rows Session 2.Host View Rows Numeric, minimum = 1, maximum = 255 [80] Keypad Mode [Session 1].Keypad Mode Session 2.Keypad Mode [Numeric] Application Local Echo [Session 1].Local Echo Session 2.Local Echo Enabled [Disabled] Lock Mode [Session 1].Lock Mode Session 2.Lock Mode Enabled [Disabled] RS-232 Baud Rate (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].RS232 BaudRate Session 2.RS232 BaudRate 1200 2400 4800 [9600] 19200 38400

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 155

SECTION 5

Customizing Your Configuration

"

"

"

"

"

"

"

"

"

RS-232 Data Bits (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].RS232 DataBits Session 2.RS232 DataBits 7 [8] RS-232 Flow (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].RS232 Flow Session 2.RS232 Flow [NONE] DTR XON/XOFF RS-232 Parity (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].RS232 Parity Session 2.RS232 Parity [NONE] EVEN ODD RS-232 Stop Bits (not supported on 2415, 2425, 2435A, 2455, 248X, 5020) [Session 1].RS232 StopBits Session 2.RS232 StopBits [1] 2 RS-232 Stream (not supported on 6400, 5020, 5055, 59XX, 17XX, 11XX) [Session 1].RS232 Stream Session 2.RS232 Stream Enabled [Disabled] Screen Lock [Session 1].Screen Lock Session 2.Screen Lock Enabled [Disabled] Send XON [Session 1].Send XON Session 2.Send XON [Enabled] Disabled Terminal Mode [Session 1].Terminal Mode Session 2.Terminal Mode [7-Bit] 8-Bit Terminal Setup [Session 1].Term Setup Session 2.Term Setup ANSI VT100 VT220 VT320 [VT340]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-27

Page 156

Customizing Your Configuration

"

"

"

"

"

SECTION 5

VT Cursor Mode [Session 1].VT Cursor Mode Session 2.VT Cursor Mode [Cursor] Application VT220 Mode [Session 1].VT220 Mode Session 2.VT220 Mode [Char] Block Transmit BS [Session 1].Transmit BS Session 2.Transmit BS Enabled [Disabled] Use PC Character Set [Session 1].Use PC Char Set Session 2.Use PC Char Set Enabled [Disabled] Allow Negotiate About Window Size (NAWS) [Session 1].Allow NAWS Session 2.Allow NAWS Enabled [Disabled]

Display Options " NOTE:

Display options do not apply to the 2415, 2425, 2435A, 2455, and 248X Terminals, Use the Trakker Antares firmware setup menu to set the display options. "

"

"

"

5-28

Backlight State [Session 1].Backlight State Session 2.Backlight State Enabled [Disabled] Backlight Timer (6400, 17XX, 11XX) [Session 1].Backlight Timer Session 2.Backlight Timer Numeric, minimum = 0, maximum = 255 Contrast Mode (59XX, 17XX, 11XX) [Session 1].Contrast Mode Session 2.Contrast Mode [Compensated] Absolute Cursor Mode [Session 1].Cursor Mode Session 2.Cursor Mode Underln Blink Block Blink Underline [Block]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 157

SECTION 5

Customizing Your Configuration

"

"

"

"

"

Remote Baud (17XX, 11XX) [Session 1].Remote Baud Session 2.Remote Baud 9600 19200 [38400] Remote Display (17XX, 11XX) [Session 1].Remote Disp Session 2.Remote Disp Enabled [Disabled] Remote Display Remote Columns (17XX, 11XX) Session 1.Remote Cols Session 2.Remote Cols Numeric, minimum = 1, maximum = 255 [80] Remote Display Remote Rows (17XX, 11XX) [Session 1].Remote Rows Session 2.Remote Rows Numeric, minimum = 1, maximum = 255 [24] Remote Display Remote Type (17XX, 11XX) [Session 1].Remote Type Session 2.Remote Type VT100 VT220 [ANSI]

Radio Communications Options " NOTE:

Radio Communications options do not apply to the 2415, 2425, 2435A, 2455, 248X, 5020 Terminals. Set the Security ID for these terminals through the TRAKKER Antares

2400 Menu System. "

"

"

Baud Rate (UHF radio) Radio Baud Rate 4800 4800/9600 9600 The default depends on the type of radio in the terminal. Protocol (6400, 5055, 59XX, 17XX, 11XX) Radio Protocol The following qualifiers apply to UHF: RTC Adaptive Poll RTC-Diag Mode The following qualifiers apply to SST: SST SST-Diag Mode The default depends on the type of radio and is either RTC or SST. Security ID [Session 1].Security ID Session 2.Security ID String, minimum length=0, maximum length=16 [null string] Default is NORANDOWL for 6400, 5055, 17XX, 11XX, 59XX. TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-29

Page 158

Customizing Your Configuration

More Options "

"

"

"

Change Menu Password The password must be enabled and set for access to the Main Menu before you can change it. To set the password: [Session 1].Change Menu Password Session 2.Change Menu Password String, minimum length = 1, maximum length = 10 [3193693] To enable the password, see “Main Menu password.” COM Select (5055) [Session 1].Com Select Session 2.Com Select [COM 1] COM 2 Main Menu Password The password must be enabled and set for access to the Main Menu. To enable or disable the password: [Session 1].Menu Password Session 2.Menu Password Enabled [Disabled] To set the password, see “Change menu password”. Print Device (6400) [Session 1].Print Device Session 2.Print Device [RS232 Print] IRDA Print

LCD Options "

"

"

"

"

5-30

SECTION 5

Annunciator Format [Session 1].Annun Format Session 2.Annun Format [Vertical] 2455, 248X, 59XX, 5055, 5020 [Horizontal] 2415, 2425, 2435A, 6400 Annunciator Position [Session 1].Annun Position Session 2.Annun Position Upper Right Upper Left [Lower Right] Lower Left Stealth Backlight Intensity (59XX) [Session 1].BLight Intensity Session 2.BLight Intensity Numeric, minimum = 0, maximum = 15 Define Height (Scroll Window) [Session 1].Define Height Session 2.Define Height Numeric, minimum = 1, maximum = 24 [8] Define Width (Scroll Window) [Session 1].Define Width Session 2.Define Width Numeric, minimum = 1, maximum = 80 [8]