Page 139

SECTION 5

Customizing Your Configuration

CHECKCFG.EXE ignores the following: Blank lines " Leading white space (spaces and tabs) " White space on either side of any delimiter (a period, an equal sign, or a semicolon) In addition, the set-up file converts consecutive white space characters within strings to one space. For example, this line: "

Screen

Mode

=

Page Mode

;

is the same as: Screen Mode=Page Mode; You can set the Value field of any configuration parameter to “?”, which indicates that the TE configuration program should prompt the user for the appropriate value. For example, this parameter causes the terminal to prompt the user to select a screen mode from the list of values: Screen Mode = ?; Following is a sample set-up file. Program Name = CUSTOM; Screen Mode = Page Mode; Host A.Port Number = 1; Data Stream = VT220; Code 39.Encoded = Enabled; Extended Cmds = Enabled;

Parameter Formats The complete parameter list with value definitions can be directed to a file using CHECKCFG –P CFGLIT.DAT > parms.txt this command: Each parameter in the set-up file is followed by one of three different formats that indicates the type of parameter and the values it can contain. Formats are as follows: " Literal strings. List of fixed values to choose from. Example: [Session 1].Screen Mode Session 2.Screen Mode Center Cursor Corner Mode Page Mode Lazy Mode Locked Mode

Screen Mode may be qualified by Session 1 or 2. It may take the value Center Cursor, Corner Mode, Page Mode, Lazy Mode, or Locked Mode. Session 1 is the default qualifier. These configuration lines are valid: Screen Mode = Lazy Mode; Session 1.Screen Mode = Lazy Mode; Session 2.Screen Mode = Lazy Mode; TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-11

Page 140

SECTION 5

Customizing Your Configuration

"

Numeric parameters. Numeric parameters have minimum and maximum values. Parameters can be either decimal or hexadecimal: " Decimal parameters consist of digits 0 through 9. " Hexadecimal parameters consist of 0x or 0X, followed by 1 to 4 digits of 0 through 9, a through f, or A through F. These are equivalent: 160, 0xA0, and 0Xa0. Example: [Session 1].[Host A].Port Number Session 2.Host A.Port Number [Session 1].Host B.Port Number Session 2.Host B.Port Number [Session 1].Host C.Port Number Session 2.Host C.Port Number Numeric, minimum = 0, maximum = 65535

Port Number is a variable with a minimum value of 0 and a maximum of 65535. These lines are valid: Port Number = 1; Session 1.Host A.Port Number = 1; Session 2.Host A.Port Number = 1; "

String parameters. String parameters are variables with minimum and maximum lengths. Example: Program Name String, minimum length = 8, maximum length = 8

Program Name is unqualified. It must have eight characters. These configuration lines are valid: Program Name = ABCDEFGH; Program Name = FWP248H0;

Verifying Your Configuration Use the CHECKCFG utility to verify that you properly configured your set-up file. CHECKCFG reads your configuration and reports any syntax errors. To get the utility, contact your Systems Engineer. To verify your configuration: Type: checkcfg <input config file> cfglit.dat config.dat <input config file> is the name of your parameter set-up file. " CFGLIT.DAT contains the strings that appear in the configuration menus, parameter files, and system messages. " CONFIG.DAT is the name of the output file you will download to the terminal. This file must be named CONFIG.DAT. You are ready to download CONFIG.DAT to the terminal when CHECKCFG reports no errors. For download instructions, see “Downloading Files” on page 5-41. "

5-12

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 141

SECTION 5

Customizing Your Configuration

If CHECKCFG reports an error, use a text editor to open your set-up file and correct it. The following chart lists the system messages CHECKCFG may display. ID Number

Default String

Description

Can’t open file Bad option name

The input config (configuration) file could not be located. The right side of an expression in the input config file is an invalid name. The input config file contains a syntax error. The right side of an expression in the input config file is a string that is too long for the specified parameter. The parameter table in the configuration program contains a bad value. This error is for testing purposes only and should never occur. The right side of an expression in the input config file is a number that is out of range for the specified parameter. The right side of an expression in the input config file is a string that is invalid for the specified parameter. The right side of an expression in the input config file should be a numeric value but contains nonnumeric data. A line in the input config file does not contain the required “=” (equal sign). A line in the input config file is not terminated by a “;” (semicolon).

Syntax error Bad string length Unknown type Value out of range Bad value Expected numeric Missing ’=‘ Missing ’;‘

F000 F001 F002 F003 F004 F005 F006 F007 F008 F009

Parameters and Qualifiers " NOTE:

If parameters are duplicated, an error is not generated. Instead, the terminal will process the entire file and use the last entered value of the duplicated parameter.

Parameters in the set-up file apply to all model numbers unless otherwise noted here. The following pages list each parameter and its qualifiers. Some qualifiers have default values. If you want to use the default value, you can omit the qualifier from the parameter set-up file. Default qualifiers are listed between square brackets “[ ]” in this section. The CFGLIT.DAT file specifies the text of set-up menus or system messages. Parameters and qualifier strings in the set-up file assume you are using the default CFGLIT.DAT file. To customize CFGLIT.DAT, see “Changing Text” on page 5-34. The Trakker Antares terminals (2415, 2425, 2435A, 2455, 248X) do not support dual sessions.

Set-Up Parameters Options "

Channel (900 MHz radio) [Session 1].[Host A].Channel Session 2.Host A.Channel [Session 1].Host B.Channel Session 2.Host B.Channel [Session 1].Host C.Channel Session 2.Host C.Channel 10 25 30 25 30 35 40

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-13

Page 142

Customizing Your Configuration

"

" NOTE:

"

"

Frequency (S-UHF radio) [Session 1].[Host A].Frequency Session 2.Host A.Frequency [Session 1].Host B.Frequency Session 2.Host B.Frequency [Session 1].Host C.Frequency Session 2.Host C.Frequency Numeric, minimum=0, maximum=0xFFFFFFFF Host Name (6400, 5020, 5055, 59XX, 17XX, 11XX) [Session 1].[Host A].Host Session 2.Host A.Host [Session 1].Host B.Host Session 2.Host B.Host [Session 1].Host C.Host [Session 1].Host C.Host String, minimum length = 0, maximum length = 16 [null string] Lan ID [Session 1].[Host A].Lan Session 2.Host A.Lan [Session 1].Host B.Lan Session 2.Host B.Lan [Session 1].Host C.Lan Session 2.Host C.Lan Numeric, minimum = 0, maximum = 254 [0] applies to 900 MHz

Values greater than 15 on terminals with OpenAir or 802.11 radios have a MOD 16 operation done on the terminals. For example, LAN IDs 0, 16, and 32 all equal 0 (zero). "

5-14

Data Stream [Session 1].[Host A].Data Stream Session 2.Host A.Data Stream [Session 1].Host B.Data Stream Session 2.Host B.Data Stream [Session 1].Host C.Data Stream Session 2.Host C.Data Stream [Native] (6400, 5020, 5055, 59XX, 17XX, 11XX) [3270] 5250 VT220

“VT” will be the new default for the Data Stream in a later version. "

" NOTE:

SECTION 5

Mode [Session 1].[Host A].Mode Session 2.Host A.Mode [Session 1].Host B.Mode Session 2.Host B.Mode [Session 1].Host C.Mode Session 2.Host C.Mode For 900 MHz radio: DS 225K DS 090K DS 450K For S-UHF radio: Freq Agility Single Freq

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 143

SECTION 5

Customizing Your Configuration

"

"

"

"

"

"

"

Port Number [Session 1].[Host A].Port Number Session 2.Host A.Port Number [Session 1].Host B.Port Number Session 2.Host B.Port Number [Session 1].Host C.Port Number Session 2.Host C.Port Number Numeric, minimum = 0, maximum = 65535 [0] Radio Configuration Number [Session 1].[Host A].Radio Config# Session 2.Host A.Radio Config# [Session 1].Host B.Radio Config# Session 2.Host B.Radio Config# [Session 1].Host C.Radio Config# Session 2.Host C.Radio Config# Numeric, minimum = 0, maximum = 255 [0] Radio Number (same as unit number) [Session 1].[Host A].Radio # Session 2.Host A.Radio # [Session 1].Host B.Radio # Session 2.Host B.Radio # [Session 1].Host C.Radio # Session 2.Host C.Radio # Numeric, minimum = 0, maximum = 127 [127] Server IP [Session 1].[Host A].Server IP Session 2.Host A.Server IP [Session 1].Host B.Server IP Session 2.Host B.Server IP [Session 1].Host C.Server IP Session 2.Host C.Server IP Numeric, minimum = 1, maximum = 16 SNA [Session 1].SNA Session 2.SNA Enabled [Disabled] Telnet [Session 1].Telnet Session 2.Telnet [Enabled] this default applies to the 6400 and 5055 TE over IP options, and to the 2415, 2425, 2435A, 2455, and 248X [Disabled] Terminal Type [Session 1].[Host A].Terminal Type Session 2.Host A.Terminal Type [Session 1].Host B.Terminal Type Session 2.Host B.Terminal Type [Session 1].Host C.Terminal Type Session 2.Host C.Terminal Type Numeric, minimum = 0, maximum = 255 TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-15

Page 144

Customizing Your Configuration

"

SECTION 5

Unit Number (same as radio number) [Session 1].[Host A].Unit # Session 2.Host A.Unit # [Session 1].Host B.Unit # Session 2.Host B.Unit # [Session 1].Host C.Unit # Session 2.Host C.Unit # Numeric, minimum = 0, maximum = 127 [127]

Bar Code Parameters " NOTE:

Bar code parameters apply to 6400, 5055, 59XX, 17XX, and 11XX Terminals unless otherwise noted. 2415, 2425, 2435A, 2455, 248X, and 5020 Terminals support only the “Code 39.Encoded” parameter. "

"

"

"

"

"

"

"

5-16

BC Type Character (not supported on the 5055) [Session 1].BC Type Char Session 2.BC Type Char Enabled [Disabled] Concatenate [Session 1].Concatenate Session 2].Concatenate Enabled [Disabled] MOD 10 Check [Session 1].MOD 10 Check Session 2.MOD 10 Check Enabled [Disabled] Redundancy (not supported on the 5055) [Session 1].Redundancy Session 2.Redundancy Enabled [Disabled] Scan All Fields [Session 1].Scan All Flds Session 2.Scan All Flds Enabled [Disabled] Scan Postamble Character [Session 1].Scan PostChar Session 2.Scan PostChar Numeric, minimum = 0, maximum = 255 [0] Scan Preamble Character [Session 1].Scan PreChar Session 2.Scan PreChar Numeric, minimum = 0, maximum = 255 [0] Scan Timeout (not supported on the 6400 and 5055) [Session 1].Scan Timeout Session 2.Scan Timeout Numeric, minimum = 1, maximum = 200 [30]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

Page 145

SECTION 5

Customizing Your Configuration

"

"

Scanner Type (6400 and 5055 support Laser only) [Session 1].Scanner Type Session 2.Scanner Type [No Scanner] Wand Laser Wand Emulate Auto Detect Stream Scan [Session 1].Stream Scan Session 2.Stream Scan Enabled [Disabled]

Bar Code Symbologies "

"

"

"

"

"

"

ABC Codabar [Session 1].ABC Codabar Session 2.ABC Codabar Enabled [Disabled] Codabar [Session 1].Codabar Session 2.Codabar Enabled [Disabled] Code 11 (not supported on the 6400 and 5055) [Session 1].Code 11 Session 2.Code 11 Enabled [Disabled] Code 93 [Session 1].Code 93 Session 2.Code 93 Enabled [Disabled] Code 39 [Session 1].Code 39 Session 2.Code 39 Enabled [Disabled] Code 128 [Session 1].Code 128 Session 2.Code 128 Enabled [Disabled] Computer Identics 2 of 5 [Session 1].CI 2of5 Session 2.CI 2of5 Enabled [Disabled]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-17

Page 146

Customizing Your Configuration

"

"

"

"

"

EAN [Session 1].EAN Session 2.EAN Enabled [Disabled] Interleaved 2 of 5 [Session 1].Int 2of5 Session 2.Int 2of5 Enabled [Disabled] Plessey (6400 does not support Plessey alpha characters) [Session 1].Plessey Session 2.Plessey Enabled [Disabled] Straight 2 of 5 [Session 1].Str 2of5 Session 2.Str 2of5 Enabled [Disabled] UPC [Session 1].UPC Session 2.UPC Enabled [Disabled]

Generic Bar Code Options "

5-18

Drop Leading [Session 1].UPC.Drop Leading Session 2.UPC.Drop Leading [Session 1].EAN.Drop Leading Session 2.EAN.Drop Leading [Session 1].Code 128.Drop Leading Session 2.Code 128.Drop Leading [Session 1].Code 39.Drop Leading Session 2.Code 39.Drop Leading [Session 1].Codabar.Drop Leading Session 2.Codabar.Drop Leading [Session 1].ABC Codabar.Drop Leading Session 2.ABC Codabar.Drop Leading [Session 1].Str 2of5.Drop Leading Session 2.Str 2of5.Drop Leading [Session 1].Int 2of5.Drop Leading Session 2.Int 2of5.Drop Leading [Session 1].CI 2of5.Drop Leading Session 2.CI 2of5.Drop Leading [Session 1].Code 11.Drop Leading Session 2.Code 11.Drop Leading [Session 1].Code 93.Drop Leading Session 2.Code 93.Drop Leading [Session 1].Plessey.Drop Leading Session 2.Plessey.Drop Leading Numeric, minimum = 0 [0], maximum = 15 [0]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

SECTION 5

Page 147

SECTION 5

" NOTE:

Customizing Your Configuration

Generic bar code options must be qualified by one of the bar code symbology strings. For example: “Session 1.UPC.Max Length = 13;” "

"

Drop Trailing [Session 1].UPC.Drop Trailing Session 2.UPC.Drop Trailing [Session 1].EAN.Drop Trailing Session 2.EAN.Drop Trailing [Session 1].Code 128.Drop Trailing Session 2.Code 128.Drop Trailing [Session 1].Code 39.Drop Trailing Session 2.Code 39.Drop Trailing [Session 1].Codabar.Drop Trailing Session 2.Codabar.Drop Trailing [Session 1].ABC Codabar.Drop Trailing Session 2.ABC Codabar.Drop Trailing [Session 1].Str 2of5.Drop Trailing Session 2.Str 2of5.Drop Trailing [Session 1].Int 2of5.Drop Trailing Session 2.Int 2of5.Drop Trailing [Session 1].CI 2of5.Drop Trailing Session 2.CI 2of5.Drop Trailing [Session 1].Code 11.Drop Trailing Session 2.Code 11.Drop Trailing [Session 1].Code 93.Drop Trailing Session 2.Code 93.Drop Trailing [Session 1].Plessey.Drop Trailing Session 2.Plessey.Drop Trailing Numeric, minimum = 0 [0], maximum = 15 [0] Fix Length 1 [Session 1].UPC.Fix Length 1 Session 2.UPC.Fix Length 1 [Session 1].EAN.Fix Length 1 Session 2.EAN.Fix Length 1 [Session 1].Code 128.Fix Length 1 Session 2.Code 128.Fix Length 1 [Session 1].Code 39.Fix Length 1 Session 2.Code 39.Fix Length 1 [Session 1].Codabar.Fix Length 1 Session 2.Codabar.Fix Length 1 [Session 1].ABC Codabar.Fix Length 1 Session 2.ABC Codabar.Fix Length 1 [Session 1].Str 2of5.Fix Length 1 Session 2.Str 2of5.Fix Length 1 [Session 1].Int 2of5.Fix Length 1 Session 2.Int 2of5.Fix Length 1 [Session 1].CI 2of5.Fix Length 1 Session 2.CI 2of5.Fix Length 1 [Session 1].Code 11.Fix Length 1 Session 2.Code 11.Fix Length 1 [Session 1].Code 93.Fix Length 1 Session 2.Code 93.Fix Length 1 [Session 1].Plessey.Fix Length 1 Session 2.Plessey.Fix Length 1 Numeric, minimum = 0 [0], maximum = 99 [0] TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

5-19

Page 148

Customizing Your Configuration

"

"

5-20

Fixed Length 2 [Session 1].UPC.Fix Length 2 Session 2.UPC.Fix Length 2 [Session 1].EAN.Fix Length 2 Session 2.EAN.Fix Length 2 [Session 1].Code 128.Fix Length 2 Session 2.Code 128.Fix Length 2 [Session 1].Code 39.Fix Length 2 Session 2.Code 39.Fix Length 2 [Session 1].Codabar.Fix Length 2 Session 2.Codabar.Fix Length 2 [Session 1].ABC Codabar.Fix Length 2 Session 2.ABC Codabar.Fix Length 2 [Session 1].Str 2of5.Fix Length 2 Session 2.Str 2of5.Fix Length 2 [Session 1].Int 2of5.Fix Length 2 Session 2.Int 2of5.Fix Length 2 [Session 1].CI 2of5.Fix Length 2 Session 2.CI 2of5.Fix Length 2 [Session 1].Code 11.Fix Length 2 Session 2.Code 11.Fix Length 2 [Session 1].Code 93.Fix Length 2 Session 2.Code 93.Fix Length 2 [Session 1].Plessey.Fix Length 2 Session 2.Plessey.Fix Length 2 Numeric, minimum = 0 [0], maximum = 99 [0] Fixed Length 3 [Session 1].UPC.Fix Length 3 Session 2.UPC.Fix Length 3 [Session 1].EAN.Fix Length 3 Session 2.EAN.Fix Length 3 [Session 1].Code 128.Fix Length 3 Session 2.Code 128.Fix Length 3 [Session 1].Code 39.Fix Length 3 Session 2.Code 39.Fix Length 3 [Session 1].Codabar.Fix Length 3 Session 2.Codabar.Fix Length 3 [Session 1].ABC Codabar.Fix Length 3 Session 2.ABC Codabar.Fix Length 3 [Session 1].Str 2of5.Fix Length 3 Session 2.Str 2of5.Fix Length 3 [Session 1].Int 2of5.Fix Length 3 Session 2.Int 2of5.Fix Length 3 [Session 1].CI 2of5.Fix Length 3 Session 2.CI 2of5.Fix Length 3 [Session 1].Code 11.Fix Length 3 Session 2.Code 11.Fix Length 3 [Session 1].Code 93.Fix Length 3 Session 2.Code 93.Fix Length 3 [Session 1].Plessey.Fix Length 3 Session 2.Plessey.Fix Length 3 Numeric, minimum = 0 [0], maximum = 99 [0]

TE 2000t VT/ANSI Terminal Emulation Programmer’s Guide

SECTION 5