Table 4-1 continued Basic Troubleshooting Condition

Solution

A Fully Charged Battery Pack In The Computer Still Does Not Bring It To Life. None Of The LEDs Light On The Battery Pack.

Leave the same battery pack in your computer for at least 30 minutes, to allow some time to put some charge into your backup battery. Then replace the battery pack with a fully charged pack. Put the original battery pack into an external battery charger.

The LEDs On The Battery Pack Do Not Match the LEDs On The Display

It takes a minute after you put in the battery pack for your computer to check the status and display the updated battery charge level.

After A Weekend A Fully Charged Battery Pack Does Not Last The Normal Length Of Time

The computer was left for the weekend without a battery pack in it. Therefore, when you start out the week with the fresh charged battery it has to build up the charge level in the backup battery and that leaves less power for its normal days use.

Computer Reboots When A Battery Pack Is Installed

The computer was not suspended (pressing the [I/O] key to blank the display) before the battery was replaced.

Putting The Computer Into A Charging Device The Charge LED Blinks Different Colors

There is a fault state condition occurring in the battery pack or the charger. For the complete details concerning the sequence of the colors of the blinks refer to Section 2 Battery Charger LED and Error Codes on page 2-10.

Another reason can be that the backup battery may be drained. Recharge the computer for a minimum of 12 hours. If a problem still exists then send your computer to the service center.

6400 Hand-Held Computer User’s Guide

4-5

Page 142

SECTION 4

Maintenance and Troubleshooting

Table 4-1 continued Basic Troubleshooting Condition

Solution

When Putting The Battery Pack In The Charger The LED Never Turns Green

There is a fault state condition occurring in the battery pack or the charger. For the complete details concerning the sequence of the colors of the blinks refer to Section 2 Battery Charger LED and Error Codes on page 2-10.

Computer Does * Ensure that there is a main battery in. Not Turn ON When * Ensure that the main battery is charged. The [I/O] Key Is * Ensure that the battery compartment door is closed. Pressed Computer Does * Ensure the dock is plugged in. Not Turn ON When * Ensure that the battery compartment door is closed. Placed In A Dock * Reseat computer into dock to ensure proper connection. Computer Shuts Down During Use

* You may have a very low battery. Try recharging the main battery. * You may have hit the battery door latch; this causes your computer to suspend. Check the latch then press the [I/O] key to continue operation.

Computer Resets When You Replace Or Check The Main Battery

The backup battery may not be fully charged, allow at least 8 hours to completely recharge the backup battery.

Computer Turns OFF When You Open The Battery Door Latch

This is the correct operation, the unit shuts down to conserve energy and save data.

Computer Does Not Suspend

* The computer stays on when it is connected to a charging device. * The computer stays on when it is processing data or in radio communications. This is OK if connected to a charger or placed in a dock. If this is not the case, and either of these conditions continues for a long period of time, contact Intermec support personnel, as this condition runs down the batteries.

4-6

6400 Hand-Held Computer User’s Guide

Page 143

SECTION 4

Maintenance and Troubleshooting

Table 4-1 continued Basic Troubleshooting Condition

Solution

Computer Displays A Bad Tcom Message

* The computer may not be making full contact with the dock. Try reseating the unit in the dock. * The dock may not be properly connected to the host. Make sure there is a connection. TCOM errors may happen when telephone service is lost, or for reasons not related to the physical connection.

Computer Takes A Normal time is between 30--45 seconds. If you do not have Long Time To Boot your computer connected to a charging source the booting Up After A Reset should be less than 30 seconds. Short beeps about one second apart occur during the booting process to indicate that your computer is working. If it takes longer than that, contact Intermec support personnel. Tethered Laser Data And Internal Laser Engine Data Does Not Show Up In The Key Buffer

Load 64SCN7B with both “--e” and “--w” command lines switches. Both are needed to enable power to the internal engine and direct the data from both scanners to the keyboard.

Wedge Mode Application Dies When Scanning Data Using A Tethered Scanner, But Works Fine With The Integrated Scanner

Check for non-displayable preamble, postamble, prefix, or suffix characters being sent by the laser. The internal laser engine sends a postamble of <cr-lf> by default. Either disable them or code the application to handle them. The integrated scanner and tethered lasers may be configured by scanning setup bar codes.

Tethered Scan Data Does Not Show Up In The Key Buffer But The Integrated Laser Data Does

Ensure that the tethered laser is configured for 9600, n, 8, 1 and the bar code data is prefixed with an STX (0x02) and suffixed with an ETX (0x03).

6400 Hand-Held Computer User’s Guide

4-7

Page 144

SECTION 4

Maintenance and Troubleshooting

Table 4-1 continued Basic Troubleshooting Condition

Solution

Computer Does WARNING: Do Not Look Into Scanner Not Scan Bar Code * Ensure that there is a main battery in. * Ensure that the main battery is charged. * Ensure that the battery compartment door is closed. * Ensure the bar code symbology is turned On. Application has to have scanner turned On. * Ensure the scanner lens is clean. * Ensure the bar code is free of smears or dirt. Refer to instructions for Scanning beginning on page 2-15. Pressing The Scan * Normal operation is that the scan key on computer wakes Key Does Not Turn it up, but if using a tethered scanner it does not. ON Computer * Ensure that there is a main battery installed. * Ensure that the main battery is charged. * Ensure that the battery compartment door is closed. Can Not Scan Interleaved 2 Of 5 Bar Codes

4-8

Interleaved 2 of 5 only decodes bar codes that are exactly the same number of characters as programmed into the integrated scanner lengths 1 and 2 parameters. By default, the lengths are 14 and 0. A length of 0 means disabled, so only 14 character bar codes will decode. Ensure one of the lengths is set to the length of your bar code and the other disabled. Do not leave both lengths set, if only one is needed, because Interleaved 2 of 5 can easily mis-decode into an incorrect length.

6400 Hand-Held Computer User’s Guide

Page 145

SECTION 4

Maintenance and Troubleshooting

Table 4-1 continued Basic Troubleshooting Condition

Solution

Hear A Beep When Programming Scanner To Enable Interleaved 2 Of 5, But Not When Trying To Set Length 1

Beeps are heard at the end of a programming sequence. Enabling Interleaved 2 of 5 is a one-bar code sequence. Setting an Interleaved 2 of 5 length is a three-bar code sequence. You will not hear the beep until the third (last) bar code is scanned. Please note, you must scan each bar code of a multiple sequence within a 1/2 second of each other. This is most easily accomplished by making a high resolution copy of the appropriate bar codes and arranging them one above the other.

Printers Flow Control On The Serial Port Causes Missing Data

Ensure when loading 64SCN7B that the “--t0” switch is used to disable its handling of serial port data as scanner data. Otherwise, 64SCN7B is reading any XON/XOFF messages from the printer.

“DASI Scanner HW Initialization Failed.”

Press any key to proceed. By default, 64SCN7B will try to initialize the integrated scanner. If your computer does not have an integrated scanner, turn off the handling of it with the 64SCN7B command line switch “--i0”. The error message will not cause any problems. If you do have an integrated scanner, it is inoperative and needs to be repaired.

Running TN.EXE Does Not Display Data

Add the “--p” command line switch to 64SCN7B --e--w. Also, ensure the [PCTCP TN] section of the PCTCP.INI files contains “screen-saver=yes”. TN.EXE bypasses the BIOS key buffer, but TN is not reading the buffer. The “--p” switch causes 64SCN7B to send the keys to the hardware instead of the BIOS. The “--p” switch may be tried for any software that reads keys directly from the hardware rather than the BIOS.

If these basic solutions do not solve your problem, there could be a number of possible causes. Additional things to try: "

Refer to the software documentation written for your application. This documentation may contain troubleshooting information. 6400 Hand-Held Computer User’s Guide

4-9

Page 146

Maintenance and Troubleshooting

"

"

"

SECTION 4

If you purchased your computer from an Intermec VAR, contact them before contacting an Intermec Customer Service Center. Contact the Customer Support Specialist at your Intermec Customer Service Center. Your regional Intermec Customer Service Center is fully staffed and equipped to repair your computer. Customer Support Center addresses and telephone numbers are printed on a Product Service Information card. This document is packed with all Intermec products. Call the Intermec 24-hour Customer Response Center at 1--800--755--5505.

Diagnostic Information Your computer is equipped with diagnostics. You might be asked to perform tasks to help the Intermec Customer Support Specialist or the Customer Response Hot Line Specialist diagnose the problems that you are having.

4-10

6400 Hand-Held Computer User’s Guide

Page 147

SECTION 4

Maintenance and Troubleshooting

Repair Service If you send your computer in for service, be sure to carefully pack the unit and include a description of the problem and the measures you tried to correct it. Include any printout (if applicable) and/or write down displayed error messages to illustrate the problem. Also give complete details of events and circumstances leading up to the failure. Include your name, address, and phone number. If possible pack all products in their original boxes. If the original containers are not available, carefully pack each piece and provide plenty of packing material. This helps prevent additional damage to your product while in transit.

6400 Hand-Held Computer User’s Guide

4-11

Page 148

Maintenance and Troubleshooting

4-12

6400 Hand-Held Computer User’s Guide

SECTION 4

Page 149

Appendix A

Connector Pin-Outs "

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

8-Pin Docking Connector (standard) 6

8

7

5

2

4

3

1

Computer Bottom End View (Without Optional Communication Endcap)

Pin

Signal

Function

1 2 3 4 5 6 7 8

BCLK 12.0 Volts GND BDAT TXD RXD RTS CTS

Battery Clock Charge Power Ground Battery Data Transmit Data Receive Data Request To Send Clear To Send

Figure A-1

8-Pin Docking Connector Pinouts 6400 Hand-Held Computer User’s Guide

A-1

Page 150

APPENDIX A

Connector Pin-Outs

Optional Communication Adapter 9-Pin D-Sub Connector Negative contact

1

2

3

4

5

6

7

8

9

Positive contact

Pin

Signal

Function

1 2 3 4 5 6 7 8 9

No Connect RXD TXD looped to DSR GND looped to DTR RTS CTS Vcc

Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Send Ready Request To Send Clear To Send 5 volts *

Figure A-2

9-Pin D-Sub Connector Pinouts

B CAUTION:

A-2

* 5 volts on pin 9 is for use with tethered scanners and printers only, this may damage modems.

6400 Hand-Held Computer User’s Guide