The text of a manual · part 13 of 20

6400 Hand-Held Computer User's Guide, pages 121 to 130

Pages 121 to 130 of 196

The original document is the PDF (2.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 6400

Page 121

SECTION 3

Terminal Emulation Menu Screens

802.11 radio’s only.

Peripherals 1) Radio Test 2) RS232 Test 3) Display Test 4) Keyboard Test 5) Scanner Test

802.11 Radio Test Radio Test PRI: v4.0 SEC: v4.13 RFLINK: ssssss SNR: 99dBm SSID: ssss B SSID: xxxxxxxxxxxx TxRated:xMb/s std

"

"

"

Adequate Dummy MAC Address

Pri, is the primary version of low--level radio firmware. Sec, is the secondary version of the low--level radio firmware. RFLink, is a general description of the overall quality of RF connection between the Lucent radio in the 6400 (station) and the radio in the AP. The Lucent radio grades the RF link on a scale between 0 and 92. This value represents the RF channel Signal-to-Noise Ratio. The RF link quality descriptions are assigned as shown in this table. Table 3-1 Possible RF Link Descriptions SNR

Description

0 .. 23

Adequate

24 .. 47

Good

48 .. 92

Excellent 6400 Hand-Held Computer User’s Guide

3-49

Page 122

Terminal Emulation Menu Screens

"

"

"

EXAMPLE:

3-50

SECTION 3

Signal-to-Noise Ratio (SNR), is calculated by dividing the RF signal level by the RF noise level. The result is a number that indicates the overall communications quality of the RF link and is expressed in dBm. Service Set ID (SSID), is a 32 character, alphanumeric string that identifies the service set, or infrastructure, with which the 6400 is currently associated. The SSID is a user configurable parameter. The SSID is configured by the keyword WaveLAN_Network_Name in the net.cfg file. Setting WaveLAN_Network_Name to ANY allows the station to associate with any service set. Basic Service Set ID (BSSI), it the 6 byte MAC address of the Lucent radio in the AP with which the station is associated. The Lucent radio in the terminal may associate with a non-Lucent (but 802.11 compliant) radio in an AP. Looking at the first three bytes of the MAC address (OUI) can help identify the AP radio’s manufacturer.

An OUI of “00601D” points to a Lucent radio, while “0020A6” indicates a Proxim radio.

6400 Hand-Held Computer User’s Guide

Page 123

SECTION 3

Terminal Emulation Menu Screens

"

TXRate, is the data rate (in Mb/s) of the last message transmitted by the Lucent radio. The default TXRate of 2 Mb/s and will be displayed when the terminal starts up and has not transmitted a frame yet. High speed Lucent radio’s are capable of data rates of 1 Mb/ s, 2 Mb/s, 5.5 Mb/s, and 11 Mb/s. The TxRate 5.5 Mb/s data rate is displayed as 6 Mb/s. This occurs because the Lucent radio reports an integer value for current transmission data rate, so the data rate of 5.5 Mb/s is rounded up to 6 Mb/s. Several factors influence the rate at which a frame is transmitted. First, you can configure the radio’s transmission rate in the net.cfg file. The keyword Transmit_Rate in the net.cfg holds a numeric value indicating the transmission rate. Table 2 shows the Transmit_Rate values and their respective supported transmission rates that are available in the high speed Lucent radio’s. The transmission rate is also affected by the characteristics of the RF link. If the radio encounters problems sending a higher transmission rate because the RF link is weak, busy, or noisy, then the radio may retry the transmission at a lower data rate. Therefore, the TxRate reported may be lower than the configured transmission rate. We only report the transmission rate of the most recent and successful transmission. Table 3-2 Supported Transmission Rates for the High Speed Lucent Radio’s Value

Description

1

Fixed Low (1 Mb/s)

2

Fixed Standard (2 Mb/s)

3

ARS High (11 Mb/s = default) 6400 Hand-Held Computer User’s Guide

3-51

Page 124

SECTION 3

Terminal Emulation Menu Screens

Table 3-2 continued Supported Transmission Rates for the High Speed Lucent Radio’s Value

Description

4

Fixed Medium (5.5 Mb/s)

5

Fixed High (11 Mb/s)

6

ARS Standard (2 Mb/s)

7

ARS Medium (5.5 Mb/s)

RS232 Test The RS232 Test checks the data communication port on the bottom of the hand-held computer. This test requires a special loop-back connector that links the following input and output pins on the data connector: The TX output to the RX input " The DTR output to the DSR input " The CTS output to the RTS input The RS232 Test screens are shown below. "

3-52

6400 Hand-Held Computer User’s Guide

Page 125

SECTION 3

Terminal Emulation Menu Screens

RS232 Test Attach RS232 Loopback Connector Press Enter

RS232 Test Results: RTS-CTS:

xxxx

TX-RX: xxxx Any Key To Stop

To run the test: 1. Select the RS232 Test from the Peripherals menu. 2. Attach the loop-back connector to the round connector on the bottom of the hand-held computer, then press [ENT]. The display changes to the second RS232 Test menu (shown above). The condition of each line-pair displays as passing or failing the test. If any test fails, the hand-held computer should be returned for service.

Display Test The Display Test activates each element in the LCD display. If a line appears broken, or there are gaps in the display, the LCD panel needs to be replaced.

6400 Hand-Held Computer User’s Guide

3-53

Page 126

Terminal Emulation Menu Screens

SECTION 3

To perform the Display Test: 1. From the Display Test Menu, press [ENT] to start the test. The display screen is painted with a series of vertical lines. 2. Visually inspect the lines. For the test to pass, all lines should appear clear and complete (no broken segments); press [ENT]. The display screen is then painted with a series of horizontal lines. 3. Visually inspect the lines using the same criteria. The display screen is then painted black. 4. Visually inspect the painted black lines. For the test to pass, the screen should be uniformly black; press [ENT]. You return to the Peripherals menu.

3-54

6400 Hand-Held Computer User’s Guide

Page 127

SECTION 3

Terminal Emulation Menu Screens

Keyboard Test The Keyboard Test lets you test each key on the hand-held computer keyboard. The Keyboard Test screen is shown below:

Keyboard Test Press A Key ENTER To Exit Key = ’A’

To perform this test, press each key on the keyboard (except the [ENT] key). A character corresponding to the key pressed should appear on the display.

Scanner Test The Scanner Test allows you to test the operation of an attached bar code scanner. From the Scanner Test menu, scan an enabled bar code. For this test to pass the bar code and the bar code length should appear on the display. Press any key to exit. The Scanner Test screen is shown below.

Scanner Test Scan Code> Length>

6400 Hand-Held Computer User’s Guide

3-55

Page 128

SECTION 3

Terminal Emulation Menu Screens

Memory View This menu is reserved for engineering test and evaluation.

Memory View F1 - Exit F2 - Heap F3 - Far Heap F4 - Memory Dump Address: xxxxxx

Packet Driver Test The Packet Driver tests allow you to test the accuracy of data transmissions to and from the hand-held computer.

Packet Driver 1) 2) 3) Packet Stats 4) Histogram 5) 6)

3-56

6400 Hand-Held Computer User’s Guide

Page 129

SECTION 3

Terminal Emulation Menu Screens

Packet Stats The Packet Stats (statistics) test shows the number of packets sent and received, number of errors, and number of packets dropped.

Receive Statistics Pkt Chr Err Lost xxx xxx xxx xxx

Transmit Statistics Pkt Chr Err xxx xxx xxx

Tranaction Statistics Qty Sec Qty/Min Ops xxx xxx xxx xxx

RTC Statistics * See Text ’Histogram Options’

6400 Hand-Held Computer User’s Guide

3-57

Page 130

SECTION 3

Terminal Emulation Menu Screens

Histogram Opts An Intermec engineer may ask you to access this menu if your hand-held computer has problems. From this menu you can provide the Intermec system engineer with vital information about your hand-held computer. The actual menus are not shown in this manual, however some of the general terminology is shown below. Several of the menu options, such as “Clear. . ., ” are password-protected and are only accessible if the engineer provides you with the correct password. Terminology you might see: avg tx time " avg trans time " ptt (push-to-talk) count " addrs on list " poll no data " send retries " rcv retries " reset count " interval time " time bucket # An Intermec system engineer works with you on these selections. "

Histogram Opts 1) Start 2) Stop 3) View

3-58

6400 Hand-Held Computer User’s Guide