Page 61

APPENDIX B

DOS Utilities Program

NETWORK PARAMETERS with NRINET or TFTP If you select this option and Option 2. COMM SETTINGS is set to NRINET or TFTP, this “Network Parameters” popup menu appears: NETWORK PARAMETERS SERVER NAME SERVER IP ADDRESS 0. 0. 0. CLIENT IP ADDRESS 0. 0. 0. ROUTER 0. 0. 0. SUBNET MASK 0. 0. 0. [ESC]QUIT

0 0 0 0

If you have an alphanumeric keyboard, press the characters to the host name, then press the [ENT] key to save the entry and move to the next field. If you have a numeric keyboard, use the A and " keys to scroll back and forth through the given set of alphanumeric characters. After a character is selected, press the [ENT] key to enter that character. Press [ENT] again to move to the next field. Press the Y or B keys to move between fields. Press [ENT] to save the entries and exit the “Network Parameters” menu. Press the [ESC] key to exit without saving the entries.

600 Series Industrial Mobile Computer User’s Guide

B-23

Page 62

DOS Utilities Program

APPENDIX B

NETWORK PARAMETERS with NOVELL NETWARE If you select this option and Option 2. COMM SETTINGS is set to NOVELL NETWARE, this frame type drop-down list appears: 1. 802.2 2. ETHERNET II 3. 802.3 RAW 4. 802.2 W/ SNAP

Press the number of a frame type, or press the Y or B keys to scroll through the list and press the [ENT] key to enter. Press the [ESC] key to exit this drop-down list without changing the frame type.

Option 4 MODEM PARAMETERS Modem Parameters appears as Option 4 when Option 2. COMM SETTINGS is set to MODEM/DIRECT. If you select this option, the “Modem Parameters” pop-up menu appears. MODEM PARAMETERS 1. MODEM TYPE NM2400/NM2400A 2. PROTOCOL TTY 3. BPS RATE 2400 4. DATA FORMAT 8N1 5. AUTO ANSWER ESC [ESC]DONE

Press the number of a modem parameters option, or press the Y or B keys to scroll through the list, then press the [ENT] button to enter.

Suboption 1 MODEM TYPE If you select this suboption, a drop-down list appears with supported modem types. Press the Y or B keys to scroll through the list, then press the [ENT] button to enter. B-24

600 Series Industrial Mobile Computer User’s Guide

Page 63

APPENDIX B

DOS Utilities Program

"

If you select drop-option OTHER EXTERNAL or OTHER INTERNAL, the “Modem Init String” pop-up menu appears: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 [F2]TEST STRING [ENT]O ESC]QUIT a. Enter the initialization string of the modem you are using. Refer to your modem’s reference manual for information. " NOTE:

Use A and " keys on numeric keyboards to scroll the alphanumeric character set.

" NOTE:

If you leave this menu blank, a string is not saved.

b. Press the [ENT] key to enter the string or press [ESC] to exit this pop-up menu.

600 Series Industrial Mobile Computer User’s Guide

B-25

Page 64

DOS Utilities Program

" NOTE:

APPENDIX B

Testing the modem initialization string is optional.

To test the modem string, do the following: a. Press the [F2] key. The computer replies with “PLEASE WAIT” and tests the string: "

MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 PLEASE WAIT . . . [F2]TEST STRING [ENT]OK [ESC]QUIT

Momentarily, the computer displays the modem’s response: MODEM INIT STRING ATE0V0Q0&M0&S1&C1& D2&R/QX0L1 RESULT:

97

[F2]TEST STRING [ENT]OK [ESC]QUIT

" NOTE:

Zero indicates the modem was successfully configured. Any other value indicates an error. See page B-13 for a list of modem errors. If you purchased this modem from the Norand Mobile Systems Division, contact Customer Response Center at 800-755-5505 (U.S.A. or Canada) or 425-356-1799. If this modem is not from the Norand Mobile Systems Division, contact your modem supplier.

b. Press the [ENT] key to update the modem initialization string. The computer returns to the “Modem Parameters” pop-up menu with OTHER EXTERNAL or OTHER INTERNAL assigned.

B-26

600 Series Industrial Mobile Computer User’s Guide

Page 65

APPENDIX B

DOS Utilities Program

Suboption 2 PROTOCOL If you select this suboption, a drop-down list of available protocols appears: 1. TTY

" NOTE:

TTY is the only protocol currently supported.

Press the number of a protocol, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the “Modem Parameters” pop-up menu with the selected protocol assigned. Press the [ESC] key to exit this drop-down list.

Suboption 3 BPS RATE If you select this suboption, the BPS Rate drop-down list appears with various bits per second (BPS) rates: 1. 2. 3. 4. 5. 6. 7. 8.

1200 2400 4800 9600 19200 38400 57600 115200

Press the number of a BPS rate, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the “Modem Parameters” pop-up menu with the selected BPS rate assigned. Press the [ESC] key to exit this drop-down list.

600 Series Industrial Mobile Computer User’s Guide

B-27

Page 66

DOS Utilities Program

APPENDIX B

Suboption 4 DATA FORMAT If you select this suboption, the “Data Format” drop-down list appears: 1. 8N1 2. 7E1

Press the number of a data format, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the “Modem Parameters” pop-up menu with the selected data format assigned. Press the [ESC] key to exit this drop-down list.

Suboption 5 AUTO ANSWER This suboption is not supported at this time.

Option 5 NETWORK INTERFACE This option appears only if the computer supports multiple network interface. “Network Interface” appears as Option 5 when Option 2. COMM SETTINGS is set to NRINET, TFTP, or NOVELL NETWARE. If you select this option, the “Network Interface” drop-down list appears: 1. ETHERNET 2. RS485

Press the number of a network interface, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the “Communications” menu with the selected network interface assigned.

B-28

600 Series Industrial Mobile Computer User’s Guide

Page 67

APPENDIX B

DOS Utilities Program

Option 5 PHONE NUMBER Phone Number appears as Option 5 when Option 2. COMM SETTINGS is set to MODEM/DIRECT. If you select this option, the “Phone Number” pop-up menu appears: PHONE NUMBER 9...13193693282 [ . ]DIALING PAUSE [ENT]OK [ESC]QUIT

Enter up to 16 characters. Use the [¬SP] key to backspace; use the [CLR] to reset to the previous phone number, and press [.] to insert a dialing pause command (“,”). Press the [ENT] key to save the new phone number and return to the “Communications Settings” menu. Press the [ESC] key to exit this pop-up menu.

600 Series Industrial Mobile Computer User’s Guide

B-29

Page 68

DOS Utilities Program

APPENDIX B

Option 9 ADVANCED UTILITIES If you select this option, the “Advanced Utilities” menu appears: NORAND UTILITIES ADVANCED UTILITIES 1. SET DATE/TIME 2. BATTERY STATUS

Press the number of an advanced utility option, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. " NOTE:

B-30

Suboption 4 FORMAT RAM CARD appears only if the FORMAT.COM program is in the PATH.

600 Series Industrial Mobile Computer User’s Guide

Page 69

APPENDIX B

DOS Utilities Program

Suboption 1 SET DATE/TIME If you select this suboption, the “Set Date/Time” pop-up menu appears: SET DATE/TIME DATE: TIME:

01/20/80 23:12:04 [ESC]QUIT

Enter numbers for the month, day, year (1980--2079), hour, minute, and second (up to 23:59:59). Press the [ENT] key after each entry. An incorrect entry causes the computer to default to the initial number. Press the [ESC] key to exit this pop-up menu.

Suboption 2 BATTERY STATUS Use this suboption to check battery status. The “Battery Status” screen appears when you select this suboption: NORAND UTILITIES BATTERY STATUS MAIN PACK VOLTAGE CAPACITY

CHARGING 7.37 23:59

CHARGER

16.22

[ESC]QUIT

600 Series Industrial Mobile Computer User’s Guide

B-31

Page 70

DOS Utilities Program

APPENDIX B

MAIN PACK: " “OK” " “LOW”

Status of the main battery pack: Battery operating properly. Power running low, needs recharging. " “CRITICAL” Power dangerously low, recharge soon or lose all data. " “CHARGING” Main battery pack recharging. " “MISSING” Main battery pack not loaded or detected. " VOLTAGE: Amount of operational battery voltage. " CHARGER: Amount of voltage supplied by external charge source.

"

B-32