For the Intermec 600

Page 51

APPENDIX B

DOS Utilities Program

“119” Invalid name number “120” No answer “121” Name not found “122” Name in use on remote adapter “123” Name deleted “124” Session ended abnormally “125” Name conflict “126” Incompatible remote device “133” Network interface is busy “134” Too many commands outstanding “135” Invalid LAN adapter number “136” Command completed while cancel occurring “138” Command not valid to cancel “164”--“179” Unusual network condition “180”--“354” Adapter malfunction These error codes apply when COMM SETTINGS is set to MODEM/DIRECT and PROTOCOL is set to TTY: “0” No error “6” [ESC] key pressed, aborting communications “11” Invalid parameter specified in control file “23” End of transmission “101” Line lost “102” Parity error “103” Character gap too long “104” Data loss “105” Excessive NAKs (negative acknowledgements) “106” Block count error “107” Block check error “108” Block framing error “109” Control character error “2xx” Modem error “xx” Hayes response code, or code defined by program: “03” No carrier “04” Command not recognized “06” No dial tone “07” Dialed number is busy 600 Series Industrial Mobile Computer User’s Guide

B-13

Page 52

DOS Utilities Program

APPENDIX B

“08” “86” “87” “88” “89” “97” “98” “99” " NOTE:

No answer Error sending command to modem Expected numeric response not numeric Invalid response format No significant response from modem COM port disabled by system due to low battery or removal of PC card modem. Unrecognized English response Memory allocation error

For response codes not listed above, if you purchased this modem from the Norand Mobile Systems Division of Intermec Technologies Corporation, contact Customer Response Center at 800-755-5505 (U.S.A. or Canada) or 425-356-1799. If this modem is not from the Norand Mobile Systems Division, contact your modem supplier.

These error codes apply when COMM SETTINGS is set to NOVELL NETWARE: “0” “6”

No error User aborted communications by pressing [ESC] key. “100” Connection to host failed. Verify network connection, verify that PENKEY login name exists on host. “101” Could not access include file. Verify existence of include file on host. “102” Could not allocate needed memory.

B-14

600 Series Industrial Mobile Computer User’s Guide

Page 53

APPENDIX B

DOS Utilities Program

These error codes apply when COMM SETTINGS is set to NRINET: “0” “6” “800” “801” “802” “803” “804” “806” “807” “808” “809” “810” “811”

“812”

“813”

“814”

No error User aborted communications by pressing [ESC] key. PC TCP/IP kernel is missing. Invalid client IP address. Make sure the entry for CLIENT IP ADDRESS is correct, or make sure the DHCP server is running. Invalid Service or Service Type, or invalid port number. Invalid host name or IP Address. Make sure the entry for SERVER NAME is correct, and that the server is running. Could not create socket. Check all cables and network connections. Block sent was incomplete or block received was incomplete. Client and server negotiation failed. Server specified an unsupported block size. Invalid buffer pointer. All server connections are already in use. Try again later. Timeout while sending data. Connection to remote machine dropped. Make sure the host is still running, and check all cables and network connections. Timeout while receiving data. Connection to remote machine dropped. Make sure the host is still running, and check all cables and network connections. An attempt to send data to the server failed due to a closed connection. Ensure the server is still running, check all cables and network connections. An attempt to receive data from the server failed due to a closed connection. Ensure the 600 Series Industrial Mobile Computer User’s Guide

B-15

Page 54

DOS Utilities Program

APPENDIX B

“815” “816” “817” “818” “935” “939” “940” “948” “950” “951” “952” “954” “955” “960” “961” “962” “963” “964” “965” “966”

B-16 server is still running, check all cables and network connections. Could not access the network attach information. An error occurred reading the network attach information. Server did not respond to the connect request. Ensure the server is still running, check all cables and network connections. An error occurred reading the TCP/IP kernel information. Operation would block. Destination address required. Message too long. Address already in use. Network is down. Network is unreachable. Network dropped connection or reset. Connection reset by peer. No buffer space available. Connection timed out. Connection refused. Too many levels of symbolic links. File name is too long. Host is down. Host is unreachable. Directory not empty.

600 Series Industrial Mobile Computer User’s Guide

Page 55

APPENDIX B

DOS Utilities Program

These error codes apply when COMM SETTINGS is set to TFTP:

If using PSROM0C V2.xx: “0” “1” “6” “100” “101” “201” “202” “203” “204” “205” “206” “207”

No error. PSROB0C.EXE could not be loaded. User aborted communications by pressing [ESC] key. TCP/IP kernel is missing. Invalid client IP address. Ensure the entry for CLIENT IP ADDRESS is correct or ensure the DHCP server is running. TFTP.EXE failed. TFTP.EXE not found. Unknown server. Remote file name is invalid. Local file name is invalid. File not found on server. Timeout.

If using PSROM0C V3.xx: “202” Could not create a socket. “204” Unknown server name “205” Error sending to server. Check network connections. “206” Error receiving from server. Check network connections. “207” Receive timeout. Check network connections. “208” Server error. Server terminated transfer. Check server to find out what error occurred. “209” Error writing to file. Make sure computer has enough disk space to hold all files from the server. 600 Series Industrial Mobile Computer User’s Guide

B-17

Page 56

DOS Utilities Program

APPENDIX B

Option 2 COMM SETTING If you select this option, the “Communications Settings” drop-down list appears: 1. NETWORK. . . 2. MODEM/DIRECT 3. ACCESSORY CARD 4. HANDHELD 5. REMOTE OPS 6. INTERSERVER

Press the number of a communications settings, or press the Y or B keys to scroll through the list, then press the [ENT] key to enter.

B-18

600 Series Industrial Mobile Computer User’s Guide

Page 57

APPENDIX B

DOS Utilities Program

Suboption 1 NETWORK If you select this suboption, a drop-down list appears with various networks: 1. NPCP RS485 2. NPCP RS232 3. NRINET 4. TFTP 5. NOVELL NETWARE

Press the number of a network or press the Y or B keys to scroll through the list, then press the [ENT] key to enter. The computer returns to the “Communications Menu” with the selected network assigned to Option 2. COMM SETTING. See a sample menu on page B-6. Press the [ESC] key to exit this drop-down list. The computer takes you to the “Communications Menu.”

600 Series Industrial Mobile Computer User’s Guide

B-19

Page 58

DOS Utilities Program

APPENDIX B

Suboption 2 MODEM/DIRECT If you select this suboption, the computer returns to the Communications Menu with the MODEM/DIRECT option assigned to Option 2. COMM SETTING: NORAND UTILITIES COMMUNICATIONS 1. BEGIN COMM SESSION 2. COMM SETTING MODEM/DIRECT 3. UNIT ID 4. MODEM PARAMETERS MODEM TYPE NM2400/NM2400A PROTOCOL BPS FMT TTY 2400 8N1 AUTO ANSWER ESC 5. PHONE NUMBER 9...131369282

9. ADVANCED UTILITIES

B-20

600 Series Industrial Mobile Computer User’s Guide

Page 59

APPENDIX B

DOS Utilities Program

Suboption 3 ACCESSORY CARD Suboption 6 INTERSERVER If you select either of these suboptions, the computer returns to the Communications Menu with ACCESSORY CARD or INTERSERVER assigned to Option 2. COMM SETTING. NORAND UTILITIES COMMUNICATIONS 1. BEGIN COMM SESSION 2. COMM SETTING ACCESSORY CARD 3. UNIT ID

9. ADVANCED UTILITIES

Suboption 4 HANDHELD Suboption 5 REMOTE OPS These suboptions are not supported at this time.

600 Series Industrial Mobile Computer User’s Guide

B-21

Page 60

DOS Utilities Program

APPENDIX B

Option 3 UNIT ID If you select this option, the “Change Unit ID” pop-up menu appears: CHANGE UNIT ID UNIT ID 2233233 WORKGROUP 600IPL [ALT + 4] RESET FACTORY [ESC]QUIT

Enter up to eight characters to change the Unit ID. Use the [mSP] key to backspace and use the [CLR] to restore the previous ID. Press the [ENT] key to save the new ID and return to the “Communications Settings” menu. Press the [ALT + 4] keys to reset the ID to factory default. Press [ESC] to exit this pop-up menu.

Option 4 NETWORK PARAMETERS Network Parameters appears as Option 4 when Option 2. COMM SETTINGS is set to one of these three NETWORK options: NRINET, TFTP, or NOVELL NETWARE.

B-22

600 Series Industrial Mobile Computer User’s Guide