Page 45

Learning About the 5020

1

6. Place the battery pack into the battery charger. If you have a spare charged battery pack, install it in the 5020 now. For help, see the next section. To install the main battery pack

1. Place the charged main battery pack into the battery compartment. The arrow mark on the end of the battery should be closest to the 5020 aft bracket. 2. Slide the main battery pack down until it locks into the connectors on the bottom of the battery compartment.

5020U003.eps

3. Insert the top edge of the battery door into the top of the compartment, and push the door down to close it. 4. Push the battery door latch down and slide it toward the bottom end of the 5020 to lock the door in place. 5. Reattach the back clip of the handstrap to the 5020 aft bracket if it was removed. The back clip must be attached as shown, or the handstrap will come off. Back clip

Aft bracket

5020U067.eps

1-31

Page 46

5020 Data Collection PC User’s Manual

6. Place the top clip over the pin on the top of the 5020 and set it in place. Dowel pin

5020U066.eps

Charging the Main Battery Pack You should regularly check the main battery charge status. For help, see “Checking the Battery Charge Levels” later in this chapter. If the Low Charge icon appears or if the main battery charge level drops below 50%, you should immediately charge or replace the main battery pack. If the main battery charge drops to a critical level, the Main Battery Very Low message box appears. For help, see “Recognizing Low Battery Warnings” later in this chapter. Note: ALWAYS turn off the 5020 before removing the main battery pack. If you remove a battery pack to charge it, ALWAYS install a spare charged battery pack in the 5020 to extend the life of the bridge battery. To charge the main battery pack

Do one of the following:

1-32

•

Remove the main battery pack from the 5020, and place the battery pack in the Z2400 Battery Charger. The Z2400 can fully charge the battery pack in about 4 hours. For help, see the Z2400 Battery Charger Instruction Sheet (Part No. 069994).

•

Remove the main battery pack from the 5020, and place the battery pack in the D5020 Communications Dock fast charge battery slot. Be sure the D5020 is connected to an external power supply. Using this method, the D5020 can fully charge the main battery pack in about 3 hours. For help, see the D5020 Communications Dock Getting Started Guide (Part No. 068976).

•

Leave the main battery pack in the 5020, and place the 5020 in a D5020 Communications Dock connected to an external power supply. Using this method, the D5020 can fully charge the main battery pack in about 15 hours. For help, see the D5020 getting started guide.

Page 47

Learning About the 5020

•

1

Leave the main battery pack in the 5020, and install an L5020 Serial Communications Adapter on the 5020 and connect it to an external power supply. The L5020 can fully charge the main battery pack in about 15 hours. For help, see the L5020 Serial Communications Adapter Quick Reference Guide (Part No. 068978).

You can continue to operate the 5020 while it is in the D5020 dock or when an L5020 has been installed. Note: You need to charge the 5020 batteries in an environment where the temperature is between 0°C and 40°C (32°F and 104°F). The main and bridge batteries will not charge in environments outside this temperature range.

Understanding the Bridge Battery The bridge battery is a 90 mAh manganese-dioxide lithium battery that is designed to back up all memory and the real-time clock while you remove a discharged main battery pack and insert a charged main battery pack. When you turn the 5020 back on, the 5020 resumes where it was when you turned it off. ALWAYS keep a charged main battery pack installed in the 5020 to maximize the bridge battery life. Leaving the 502X without a main battery pack for longer than it takes to install a charged battery reduces the bridge battery’s ability to hold a charge and could eventually result in data loss. The bridge battery is designed to maintain the 5020 configuration only while you are changing the main battery pack. It is not intended to retain data for extended periods of time. Note: Proper maintenance of the 5020’s bridge battery is the user’s responsibility. Failure to follow the guidelines provided will result in reduced performance and potential failure. To request service or support call 1-800-755-5505 in the U.S.A. or 1-800-668-7043 in Canada. Outside the U.S.A. or Canada, contact your local Intermec service supplier.

Charging the Bridge Battery Caution There is a risk of data loss if the main battery pack is removed and the bridge battery is not fully charged. Do not rely on the bridge battery to maintain the contents of RAM until the bridge battery is fully charged. Conseil Vous risquez de perdre des données si le bloc-batterie principal est enlevé, alors que la batterie en pont n’est pas entièrement chargée. En effet, la batterie en pont ne peut pas conserver le contenu de la mémoire vive (RAM), tant qu'elle n'est pas entièrement chargée.

1-33

Page 48

5020 Data Collection PC User’s Manual

The main battery pack charges the bridge battery with the 5020 turned on or off. The 5020 continuously monitors the bridge battery voltage level and charges the bridge battery to maximum voltage whenever necessary. If the main battery pack is low or discharged and you are not connected to AC power, it will not be able to charge the bridge battery. You should regularly check the bridge battery charge status. For help, see “Checking the Battery Charge Levels” later in this chapter. If the bridge battery charge drops to a critical level, the Bridge Battery Very Low message box appears. For help, see “Recognizing Low Battery Warnings” later in this chapter. To charge the bridge battery

Do one of the following: •

Turn off the 5020 and install a fully charged main battery pack. The main battery pack fully charges the bridge battery in approximately 72 hours. After the bridge battery has been fully charged, the main battery pack still has most of its power remaining.

•

Place the 5020 in a D5020 Communications Dock connected to an external AC power supply.

•

Install an L5020 Serial Communications Adapter on the 5020 and connect the adapter to an external AC power supply.

Note: To charge the bridge battery, you need to place the 5020 in an environment where the temperature is between 0°C and 40°C (32°F and 104°F). The bridge battery will not charge in environments outside this temperature range.

Checking the Battery Charge Levels There are two ways to check the battery charge levels: •

Open the Power applet to view the Power Properties window, which gives the charge status of the main and bridge batteries. For help, see the next section.

•

Look at the Main Battery Charge icon, which is always shown in the Notification Tray. For help, see “To check the Main Battery Charge icon” later in this section.

&

To open the Power applet

1. Press to open the Start menu and press

2. Press . The Control Panel appears.

1-34

!

to select Settings.

Page 49

Learning About the 5020

!

&

1

3. Press to select the Power applet and press . The Power Properties information box appears, showing main and bridge battery charge status.

& " !

Press to close the Power Properties information box and return to the Control Panel. 4. Press 5. Press

& twice. The File menu appears.

to select Close and press to return to the 5020 desktop.

To check the Main Battery Charge icon

•

Look in the Notification Tray next to the Start button. The Main Battery Charge icon is always shown here. Icon

Description

The main battery pack is at or near full charge. Battery is charged 75% to 100% of capacity. Full Charge

Half Charge

The main battery pack is charged to about 50% capacity.

The main battery pack is at a critically low level and needs to be charged immediately. Low Charge

Unknown Main Battery Status

Indicates the main battery pack is charging or the status is not known. Note: If the Low Charge icon appears, you should immediately turn off the 5020 and charge the main battery pack. For help, see “Charging the Main Battery Pack” earlier in this chapter.

1-35

Page 50

5020 Data Collection PC User’s Manual

You can also put focus on the Main Battery Charge icon to open the Power applet.

$% 9

To place focus on the Main Battery Charge icon

1. Press

. The focus is placed on the Start button.

2. Press to move the focus to the Main Battery Charge icon. A message briefly appears near the icon showing the percentage of charge remaining in the main and bridge batteries and whether or not AC power is currently being applied.

$%

Note: When the focus is on an item in the Notification Tray, you can return to the 5020 desktop by pressing at any time.

$% &

3. Do one of the following:

1-36

&

•

Press

•

Leave the focus on the Main Battery charge icon and press . The Power Properties information box appears, showing main and bridge battery status. Press to close the Power Properties information box and return to the 5020 desktop.

to remove focus from the icon and return to the 5020 desktop.

Page 51

Learning About the 5020

1

Recognizing Low Battery Warnings The following low battery warnings appear if the main or bridge battery charge levels fall to critical levels. Main Battery Very Low Warning

What You Need to Do

The 5020 beeps every 15 seconds, the Power applet starts, the Low Charge icon appears in the Notification Tray, and the Main Battery Very Low dialog box appears.

1.

Press

2.

Press

3.

Exit any running applications.

4.

Press

5.

Replace the main battery pack with a spare charged battery pack, charge the main battery pack, or attach an external power supply.

% % ' to close the message box. to close the Power applet.

to suspend the 5020.

Bridge Battery Very Low Warning

What You Need to Do

The Bridge Battery Very Low dialog box appears once every 15 minutes.

1.

Press

2.

Apply AC power to charge the bridge battery. The bridge battery will be fully charged in approximately 72 hours. Do not remove the main battery pack until the Power applet indicates the bridge battery has at least a 50% charge or data loss may occur.

% to close the message box.

You can remove the 5020 from AC power after the main battery pack is charged.

1-37

Page 52

5020 Data Collection PC User’s Manual

Power Management in Cold Environments If you use the 5020 in a cold temperature environment, battery life will be reduced. Battery life depends on temperature, battery model, input device, battery pack age, frequency of use, and duty cycle factors. Follow these guidelines for battery maintenance if you are using the 5020 in a cold environment: •

If you need to replace or charge the main battery pack, let the main battery pack warm up to room temperature for a half hour before you charge it.

•

Store the battery chargers and spare main battery packs in a warm (office) environment to ensure the most efficient operation.

•

If you use the 5020 for extended periods of time in a sub-freezing environment, you may need to • change the main battery pack more often.

• change the main battery pack in the sub-freezing environment to keep condensation from forming in the 5020.

• move the 5020 out of the sub-freezing environment to allow the bridge battery to charge.

• monitor the bridge battery charge closely to ensure that it remains as close to fully charged as possible.

•

Charge the 5020 batteries in an environment where the temperature is between 0°C and 40°C (32°F and 104°F). The main and bridge batteries will not charge in environments outside this temperature range.

•

Store the 5020 in an environment where the temperature is between 0°C and 40°C (32°F and 104°F) to ensure that the bridge battery charge circuit functions properly.

Using an External Power Supply You can operate the 5020 using an external power supply with any one of the following accessories: •

D5020 Communications Dock connected to an external power supply

•

L5020 Serial Communications Adapter connected to an external power supply

You can use the external power supply to operate the 5020 and to charge the 5020’s batteries at the same time. For help, see the accessory quick reference guides.

1-38

Page 53

Learning About the 5020

1

Using PC and Compact Flash Memory Cards The 5020 has two available PC card slots: • standard PC card slot located just above the scanner window

• compact flash memory card slot located inside the battery compartment

The standard PC slot in a batch 5020 can be used for a storage card, modem, or Ethernet card. If you have an RF 5020, the radio has been installed in this slot. For more information, see the next section. The compact flash memory card slot can be used for Type I flash memory cards. For more information, see “Inserting and Removing Compact Flash Memory Cards” later in this section. Note: If you are installing two storage cards (one in each slot), the Windows CE file system designates the first card inserted as “Storage Card” and the second as “Storage Card2.” To avoid changing the designation of storage cards after a cold boot, install both cards before the cold boot so that the designators remain the same through all future cold boots.

Inserting and Removing PC Cards (Batch 5020s only) A standard PC card slot is provided on the batch 5020. You can use 3.3V and 5V Type I and Type II Memory and I/O cards that comply with the PC Card Standard, February 1995, for 16-bit cards. You can use the following types of PC cards in your 5020: •

Type I SRAM Memory (storage card)

•

Type II ATA Flash Memory (storage card)

•

Type II Modem

•

Type II Ethernet

You cannot use Type III cards in the 5020. See your Intermec sales representative for a complete list of supported PC cards. The PC card slot is located on the top of the 5020 just above the laser scanner window or tethered scanner port. You can use a Type I or Type II PC card in the slot. Note: The Windows CE file system is sensitive to the order of storage card recognition when you change storage cards. When you are inserting or removing a storage PC card, follow the steps described in this section to avoid changing the designation of storage cards in the file system.

1-39

Page 54

5020 Data Collection PC User’s Manual

'

To insert a PC card (Batch 5020s only)

1. Press to turn on the 5020.

2. Make sure an extraction tab is applied to the PC card. 3. Open the slot door on the top of the 5020. The slot door drops down to reveal the PC card slot.

Slot door

5020U041.eps

4. Insert the card in the slot connector, notched end first, with the single-walled notch on the left edge of the card. Card latch

Extraction tab

Single-walled notch 5020U044.eps

5. Push the card into the slot until it fits firmly in the connector and the card latch closes. Note: Do not force the PC card into the slot. If the card stops and the card latch won’t close, remove the PC card and make sure you have the card oriented correctly. Then try to insert the card again.

1-40