The text of a manual · part 5 of 16
5020 Data Collection PC User's Manual: Chapter 1: Learning About the 5020, pages 35 to 44
Pages 35 to 44 of 144, from 5020 Data Collection PC User's Manual
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 5020
Page 35
Learning About the 5020
1
English Keypads Full
Standard
$
I
5020U304.eps
International Keypads The Euro1 and Euro2 keypads provide special keys to support Western European languages. The Euro1 keypad supports special characters for British English, French, Italian, Portuguese, and Spanish. The Euro2 keypad supports special characters for British English, Danish, Dutch, German, Finnish, Norwegian, and Swedish. The Euro keypads allow you to access accented characters ( À Á Â Ã Ä Å ). Accented characters are provided with floating accents as on many standard European keyboards. With floating accents, first you press the key for the accent and then you press the letter to which the accent is to be associated. The resulting character is the accented character. Note: No accent characters appear until you press the second key.
1-21
Page 36
Page 37
Learning About the 5020
1
Euro1 Full Alphanumeric Keypad (Not available for Euro2 language option)
Euro 1
I
5020U310.eps
1-23
Page 38
5020 Data Collection PC User’s Manual
Euro1 and Euro2 Standard Multifunction Keypads
Euro 1
Euro 2
Tab
A
Tab
B
&
C
7 E
D
F
5
4 H
G
2 ?
J
?
K
B
&
C
7
$
E
H
3
1
I
Space
@
F11
F12 N
M
F2
F1 Q
«
[
F6 V
F7
F8
W
M1
\
S
X
I
#
3 ?
K
I
0 O
/
<
T 2 >
F9 Ins
Delete %
U
F11
Q
F6
F10 V
Ctl
M1 Delete
Euro 1
F12 N
M
F2
F1
F5
Z
Y
M2
L
P
F4
F3
«]
R
$
2 J
0 L
F
5
4 G
#
9
8
D
6 I
@
1 Space
A
9
8
O
R
S
F7
F8
W
X
P
F5
F4
F3 T
U
F9 Z
Y
Ins
M2
F10 Ctl
¬
Euro 2
5020U032.eps
1-24
Page 39
1
Learning About the 5020
Using the Start Menu You can select the Start menu to run applications, open the Control Panel applets, change operating modes, or turn off the 5020. To open the Start menus and select an option
$%
&
1. Do one of the following: •
Press
•
Press to place the focus on the Start button and then press . .
The Start menu appears.
You can choose from these options: Choose an application from the Programs list to start it. For more information, see “Programs in the Start Menu” later in this section. Programs
Select Settings to open the Control Panel applets. For help, see Chapter 3, “Customizing the 502X Using the Control Panel,” in the 502X system manual. Settings
&
Type the path to an application in the Run dialog box entry field and press to start it. You can also browse the Windows directory to find the application you want or press the arrow keys to choose from the most recently run applications. Run
When you set a password for the 5020, you can choose this option to change operating modes. For more information, see “Managing Your Passwords” in Chapter 4 of the 502X system manual. Goto User Mode
Suspend
2. Press or
!
&
Choose this option to turn off the 5020. to select an option and press .
1-25
Page 40
5020 Data Collection PC User’s Manual
Programs in the Start Menu When you choose Programs from the Start menu, the Programs list appears.
502X Intro Choose 502X Intro to view “Introducing the 502X,” an online document intended for new 502X users. “Introducing the 502X” includes basic configuration and navigation information.
Select Fast Config to quickly set or enable basic network parameters and to connect the 5020 to your network. For help, see “Using Fast Config” in Chapter 2. Fast Config
After you have established a serial connection to a desktop PC with PC Connection, you can use ActiveSync to establish a partnership between the 5020 and your desktop PC for device management activities. For help, see “Using ActiveSync” in Chapter 5 of the 502X system manual. ActiveSync
Choose this option to open Internet Explorer. You can use Internet Explorer for Web browser-based data collection applications. For help, see “Using Internet Explorer” in Chapter 5 of the 502X system manual. IE Browser
Select DCPC Demo to verify correct operation of the 5020. For help, see “Verifying That the 5020 Is Operating Correctly” in the 5020 Data Collection PC Quick Start Guide (Part No. 068974). DCPC Demo
Varadero is a mobile framework that allows Visual Basic developers to create thin-client applications supporting multiple device platforms. For more information, go to www.abacomobile.com. Varadero
Use PC Connection to establish a serial connection to a desktop PC. You need to establish this connection before you can use ActiveSync. For help, see “Using ActiveSync” in Chapter 5 of the 502X system manual. PC Connection
Choose the Configuration application to view and change all 5020 parameters. For help, see “Using the Configuration Application” in Chapter 2. Configuration
1-26
Page 41
1
Learning About the 5020
Switching Between Applications With Task Manager If you have several applications running at the same time, you can switch between them using Task Manager.
"%
To open Task Manager and switch between running applications
"3
1. Make sure that the Alt or Ctl icons are not displayed and then press or . The Task Manager dialog box appears with the active application selected.
! !
& 3
2. To change the active application, do one of the following: •
Press or to choose another application from the list and press . The Task Manager dialog box closes and your selection becomes the active application.
•
Press or to choose another application from the list and press to select the End Task button. Press . The application you selected is closed and the next application on the list becomes active.
•
Press to select the Run button and press . The Run dialog box appears. Type the path to an application in the entry field and press to start it. You can also browse the Windows directory to find the application you want or press the arrow keys to choose from the most recently run applications.
3
&
&
&
1-27
Page 42
5020 Data Collection PC User’s Manual
Learning About the Batteries Warning The lithium-ion battery pack used in this device may present a fire or chemical burn hazard if mistreated. Do not disassemble, heat above 100°C (212°F) or incinerate. Avertissement Le bloc-batterie au lithium utilisé dans cet appareil peut présenter un risque d’incendie ou de brûlure chimique en cas de mauvais traitement. Ne désassemblez pas, ne chauffez pas à une température supérieure à 100°C (212°F) et n’incinérez pas ce bloc-batterie. There are two rechargeable batteries in the 5020: This lithium-ion battery provides the main power source to operate the 5020 and charges the bridge battery when needed. For more information, see “Understanding the Main Battery Pack” later in this section. Main Battery Pack
This manganese-dioxide lithium coin cell bridge battery backs up all memory and the real-time clock while you change the main battery pack. For more information, see “Understanding the Bridge Battery” later in this section. Bridge Battery
To get the best performance from the 5020’s batteries, follow these guidelines: •
Check the battery charge levels regularly, and charge the main battery pack when its charge becomes low. For help, see “Checking the Battery Charge Levels” and “Charging the Main Battery Pack” later in this section.
•
ALWAYS keep a charged main battery pack in the 5020. When you remove the main battery pack for charging, insert another charged main battery pack so you can continue to operate the 5020 without interruption and to maximize the bridge battery charge life.
•
To extend the life of the main battery charge, use the Automatic Shutoff feature to turn off the 5020 if it is inactive for a preset length of time. For help, see “Automatic Shutoff” in Chapter 7 of the 502X system manual.
•
To store the 5020 for an extended period, install a fully charged main battery pack to maintain data, the real time clock, and system context for a maximum of one week.
If you are using the 5020 in cold temperatures, see “Power Management in Cold Environments” later in this section. Note: ALWAYS keep a main battery pack installed in the 502X. Leaving the 502X without a battery pack for longer than it takes to install a charged battery reduces the bridge battery’s ability to hold a charge and could eventually result in data loss.
1-28
Page 43
Learning About the 5020
1
Understanding the Main Battery Pack The main battery pack is the main power source for the 5020 and charges the bridge battery when required. If the main battery pack charge goes low, you need to replace it with a fully charged battery pack or charge it as soon as possible. Replace the main battery pack with Intermec Part No. 068537 only. The use of any other battery pack may present a risk of fire or explosion. Contact your local Intermec sales representative for replacement battery packs. DISPOSE OF USED BATTERY PACKS PROMPTLY. KEEP AWAY FROM CHILDREN. To learn how to remove and install the main battery pack, see the next section. ALWAYS turn off the 5020 BEFORE removing the main battery pack. Note: ALWAYS keep a main battery pack installed in the 502X. Leaving the 502X without a battery pack for longer than it takes to install a charged battery reduces the bridge battery’s ability to hold a charge and could eventually result in data loss.
Removing and Installing the Main Battery Pack Caution Removing the battery pack while the 5020 is on may cause loss of data. Conseil Ne détachez pas le jeu de piles pendant que le lecteur est actif car cela pourrait entraîner la perte de données.
'
To remove the main battery pack
1. Press to turn off the 5020.
2. Push the top clip of the handstrap down and forward to unhook it from the dowel pin on the top of the 5020, and then lift it out. Dowel pin
5020U066.eps
1-29
Page 44
5020 Data Collection PC User’s Manual
3. Open the battery door by pushing up on the battery door latch and sliding it toward the top end of the 5020. Lift up the edge of the battery door to remove it. Top Battery door
Latch
5020U017.eps
4. Push the main battery pack up until it unlocks from the connectors on the bottom of the battery compartment.
5020U018.eps
5. Tilt the 5020 to one side and let the main battery pack drop out of the compartment into your hand.
5020U307.eps
1-30