Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 1

D5020 Communications Dock Instructions, pages 1 to 6

Pages 1 to 6 of 6

The original document is the PDF (319 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec D5020

Page 1

MyriadMM

D5020 Communications Dock Instructions

*068976-003* *068976-003*

Corporate Headquarters 6001 36th Avenue West Everett, Washington 98203 tel 425.348.2600 fax 425.355.9551 www.intermec.com

MyriadMM

Instructions

D5020 Communications Dock

Page 2

MyriadMM Intermec Technologies Corporation 6001 36th Avenue West Everett, WA 98203 U.S. service and technical support: 1-800-755-5505 U.S. media supplies ordering information: 1-800-227-9947 Canadian service and technical support: 1-800-668-7043 Canadian media supplies ordering information: 1-800-268-6936 Outside U.S.A. and Canada: Contact your local Intermec service supplier. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Intermec manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Intermec. Information and specifications in this manual are subject to change without notice. 2002 by Intermec Technologies Corporation All Rights Reserved The word Intermec, the Intermec logo, Data Collection PC, INCA (under license), MobileLAN, JANUS, IRL, Trakker Antares, EZBuilder, TE 2000, Data Collection Browser, dcBrowser, Universal Access Point, UAP, Duratherm, EasyCoder, Precision Print, PrintSet, Virtual Wedge, and CrossBar are either trademarks or registered trademarks of Intermec. Throughout this manual, trademarked names may be used. Rather than put a trademark ( or ) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

2

MyriadMM

11

Page 3

• •

•

MyriadMM Inspect the contacts on the dock and the 502X for proper alignment. Clean the optical interface windows on both the 502X and the dock. Optical interface window

5020CDI001.eps

Clean the contacts on the dock and the 502X using a cotton swab and isopropyl alcohol.

Optical interface:

Serial interface:

Electrical requirements:

up to 115200 baud

1 IR receiver, 1 IR transmitter

9-pin RS-232 null-modem cable (Part No. 070268)

85 to 264 VAC 43 to 63 Hz

Physical and Environmental Specifications

Interface speeds:

MyriadMM

Learning About the D5020 • charge the 502X batteries.

transfer data and applications to and from another device using IrDA or RS-232 serial communications.

The D5020 Communications Dock is an accessory for the Intermec 5020 or 5023 (502X) Data Collection PC™. Use the communications dock to

• •

D5020 RS-232 communications dock

D5020 IrDA communications dock

There are two models of the D5020 dock: •

Communications Dock Parts and Functions

1 2

3

Use this illustration to locate the important parts of the D5020 dock:

4

Fast charge battery slot

5020CDIS.001

1

Battery status light Indicates the charging status of the battery pack in the fast charge battery slot.

0°C to 40°C (32°F to 104°F) -20°C to 50°C (-4°F to 122°F) 0 to 95%, non-condensing

2

Power status light

Operating environment: Charging temperature: Operating temperature: Humidity:

3

Communications status light 502X and the host.

Indicates data transfer between the

Indicates the power and connection status.

Charges a battery pack in under 3 hours.

4

-20°C to 70°C (-4°F to 158°F) 0 to 95%, non-condensing

Warning To prevent fire or electric shock, do not expose the D5020 to rain or moisture.

For information on what the status lights indicate, see “Understanding the Status Lights” later in this guide.

3

Avertissement Pour éviter des risques d’incendie ou de choc électrique, ne pas exposer le D5020 à la pluie ou à l’humidité.

Storage environment: Temperature: Humidity:

10

Page 4

AC power cord (see the next section)

You need the following equipment to use the D5020 dock:

Power Cords, Cables, and Accessories

Time to Fully Charge

You can use the dock to charge the 502X main battery pack. You can charge the battery pack while it is inside the 502X or you can charge an extra main battery pack in the fast charge battery slot. You should always have a charged main battery pack in the 502X to prevent the loss of data.

Charging the 502X Batteries

MyriadMM

• IR transceiver for the D5020 IrDA communications dock

Method of Charging Battery Pack

≤ 15 hours ≤ 4 hours

MyriadMM

• Or, Intermec null-modem cable (Part No. 070268) for the D5020 RS-232 communications dock

Inside the 502X In the fast charge battery slot

Liechtenstein and Switzerland

Europe

Denmark and Greenland

South Pacific

Chile and Italy

Country

586105

586276

586267

586283

586281

586282

Part Number

•

Set the same serial or IrDA port parameters for the 502X and the serial or IrDA device.

Circuit breaker

Verify that the circuit breaker on the back of the dock is pushed in.

Connect the dock to AC power.

Insert the 502X firmly in the dock.

Ensure that the electrical outlet has power.

Be sure you have the correct Intermec cable (Part No. 070268) for the serial communications dock.

• • • •

5020CDIS002.eps

9

•

If you are unable to establish a good connection with the 502X and the green Power status light is not lit, you may need to:

Troubleshooting

Use only Intermec battery pack Part No. 068537 in the fast charge battery slot. For help on charging the bridge battery, see the 5020 Data Collection PC User’s Manual (Part No. 068975) or the 5023 Data Collection PC User’s Manual (Part No. 070698).

(Optional) D5020 Ganging Jumper Kit (Part No. 069600) to connect multiple docks

• Each of these accessories is ordered and purchased separately. For help, contact your Intermec sales representative.

Ordering Power Cords

North America and Central America

586266

The AC power cord is ordered separately. If you are using the D5020 Ganging Jumper Kit (Part No. 069600), order one power cord for every five docks. Otherwise, order one power cord for every dock.

United Kingdom

Connecting Multiple Docks The D5020 Ganging Jumper Kit (Part No. 069600) is ordered separately. The kit contains four ganging jumpers, four clips, and an instruction sheet. The ganging jumper links the power between multiple docks and the clip connects the docks together. You use the ganging jumper and clips to power up to five docks with one power cord.

4

Page 5

Setting Up the Communications Dock

MyriadMM

Setting up the dock for communications (RS-232 or IrDA).

MyriadMM

Inserting the 502X into the Dock

•

Press B to turn on the 502X.

Communications

Status Light

Flashing green Green Flashing red

Flashing green

State

Power is connected. Good connection with the 502X.

Battery pack is charging. Battery pack is charged. Battery pack is bad.

Data is being transferred.

Indicates

1.

Insert the 9-pin RS-232 connector into the COM port on the underside of the dock. Route the cable under the dock and out the back.

Cable routing channel

5020CDIS.005

COM port

RS-232 connector

Front mounting hole

Connect the other end of the cable to a serial device.

To device

Rear mounting hole (2 places)

5

2.

To set up the dock for RS-232 communications

You need to use an Intermec null-modem cable (Part No. 070268, sold separately) for RS-232 communications.

Setting Up the RS-232 Communications Dock

Setting up the dock involves these tasks:

Before setting up the communications dock, you need to choose a flat, stable, and clean surface that is within 1.5 m (5 ft) of an electrical source.

After you have connected power and communications cables, you are ready to insert the 502X into the dock and start using it. You can insert a 502X with a handstrap attached.

Inserting the 502X into the dock.

5020CDIS.003

•

Note: You must have a battery pack installed in the 502X for all operations. To use the communications dock the dock and slide it into the dock.

1. Place the 502X on the cradle surface of

2. Start your application on the 502X or on the desktop computer.

If the Power status light is green, the 502X has a good connection to the dock.

3. If the Communications status light is flashing green, data is being transmitted and received.

Understanding the Status Lights

Battery

Amber Green

The D5020 has three status lights to indicate the current status. For help finding each status light, see “Communications Dock Parts and Functions” earlier in this guide.

Power

8

Page 6

3.

4.

MyriadMM Connect the power cord to the power connector on the back side of the dock. Connect the other end of the power cord to an AC outlet.

Power cord

Power connector

5020CDIS.008

You can secure the dock to a flat surface using the two rear mounting holes and two #8 pan head screws (not provided). Do not overtighten. You can also secure the front of the dock for extra stability. Insert a #8-32 pan head screw (not provided) through the mounting surface and into the front mounting hole on the underside of the dock. Make sure the screw does not extend into the dock more than 1.27 cm (0.5 in) into the dock. Do not overtighten.

Setting Up the IrDA Communications Dock The IrDA dock does not ship with an IR transceiver. You need to purchase at least one IR transceiver for IrDA communications.

2.

1.

Position the IR transceiver 7.6 to 10.2 cm (3 to 4 in) from the IrDA port on the back of the dock.

Connect the IR transceiver to your host computer or device.

Connect the power cord to the power connector on the back side of the dock. Connect the other end of the power cord to an AC outlet.

To set up the dock for IrDA communications

3.

6

MyriadMM

Power connector

Power cord

IrDA port

IR transceiver

5020CDIS015.eps

Note: If you use the D5020 Ganging Jumper Kit (Part No. 069600) to connect several IrDA docks together, you need to position the IrDA transceiver behind the dock with which you want to communicate.

Rear mounting hole (2 places)

Setting Up the IrDA Communications Dock

4.

You can secure the dock to a flat surface using the two rear mounting holes and two #8 pan head screws (not provided). Do not overtighten.

You can also secure the front of the dock for extra stability. Insert a #8-32 pan head screw (not provided) through the mounting surface and into the front mounting hole on the underside of the dock. Make sure the screw does not extend into the dock more than 1.27 cm (0.5 in) into the dock. Do not overtighten.

7