For the Intermec 4830

Page 161

Program Mode Commands

6

The approximate data capacity (maximum number of characters allowed) for the three character sets is: Full ASCII, 1108; Alphanumeric, 1850; Numeric, 2725.

Note: 2D symbols encode data by compressing it in different amounts. Therefore, use these values as guidelines. The exact data capacity varies with the actual data being encoded.

Code One Syntax:

c13[,[,m1][,m2,m3]] There are 15 versions of Code One. Each version has a different maximum data length.

Defaults:

Notes:

,m1 = 0

Code One version, variable.

,m2 = 1

First position in the group.

,m3 = 1

Total number of symbols in the group is one symbol.

Selecting a Code One Version ,m1 is the version of Code One you are printing. c13,0[,m2,m3]

Code One, variable length (autoselects from version A to version H)

c13,1[,m2,m3]

Version A c13,2[,m2,m3]

Version B c13,3[,m2,m3]

Version C c13,4[,m2,m3]

Version D c13,5[,m2,m3]

Version E c13,6[,m2,m3]

Version F c13,7[,m2,m3]

Version G c13,8[,m2,m3]

Version H c13,9[,m2,m3]

Version S10 c13,10[,m2,m3]

Version S20 c13,11[,m2,m3]

Version S30 c13,12[,m2,m3]

Version T16 c13,13[,m2,m3]

Version T32 c13,14[,m2,m3]

Version T48

6-45

Page 162

4630 and 4830 Bar Code Label Printers User's Manual

It is important that you select the correct version of Code One for the data you are encoding. If you try to encode data in the wrong version, your symbol may not print. If your data lengths vary greatly for different labels, or if you are not sure which symbology to select, use the default setting. The printer will print the correct version of Code One (from version A to version H) based on data length. If you know your data lengths are consistent, or if the printer always chooses the same version, you should manually select the Code One version to save printer memory. When you print Code One symbols, you may notice that part of your symbol contains no data. This occurs because each version of Code One has a fixed size and the version that is large enough to accommodate all your data may be larger than you need. However; be careful about using a smaller size version, because if it is too small for your data to fit, the symbol will not print. The following table shows the data lengths that each Code One version accommodates. Note: The data lengths in the table are approximations of the maximum amount of data for each version of Code One. The printer compresses the data before it encodes it, which shortens the length of the amount you send. This condition should not affect printing, but if you select the variable length, the printer may select a Code One version that is smaller than the one listed next to your data length.

6-46 m1 Value

Code One Type

Full ASCII

Alphanumeric

Numeric

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 variable* A B C D E F G H S10 S20 S30 T16 T32 T48

10 19 44 91 182 370 732 1480 † † † 10 24 38

13 27 64 135 271 553 1096 2218 † † † 13 34 55

22 44 104 217 435 886 1755 3550 6 12 18 22 55 90

*

Printer selects the correct Code One type based on data length.

†

Encodes only numeric data.

Page 163

Program Mode Commands

6

Note: For full ASCII and alphanumeric columns, the maximum number of characters is actually less than those listed for each version of Code One. That number varies depending upon the number of character type changes (lowercase to uppercase, numeric to alphanumeric, and so on). The more shifts between these different types, the less data you can encode.

Grouping Symbols Use ,m2 (position of the current symbol in the group) and ,m3 (total number of symbols in the group) to define symbols that are part of a group. For example, a setting of [,2,5] indicates that the current symbol definition is the second in a group of five. Both ,m2 and ,m3 range from 1 to 15, with a default of 1. Note: If you are using groups of symbols with the ,m2 and ,m3 variables, make sure ,m2 (the position in the group) is never greater than ,m3 (the total number of symbols in the group). The printer does not check to ensure that you define all positions of a group. For example, if you set ,m3 to 5, and you define only three positions, the printer will print the three positions. However; when you scan these symbols, the scanner will wait for all five symbols and will not be able to transmit the data.

Defining Height and Width for Code One Code One modules must be square. Therefore, when you define a field for Code One, you only need to enter one value for both the height and width magnification. If you enter more than one value, the printer uses the last value for both height and width and ignores all previously entered magnification values. If you do not enter a value, the printer uses a default value of 3 for both height and width magnification. Using Groups of Code One Symbols You can use groups of Code One symbols to encode data so that you can scan separate symbols more efficiently. When you scan a group of symbols, the scanner accumulates the data from all members of the group and transmits the data as if it came from a single symbol.

6-47

Page 164

4630 and 4830 Bar Code Label Printers User's Manual

Maxicode Syntax: Defaults:

Notes:

c14[,m1][,m2][,m3] ,m1 = 0

Mode 0, Structured Carrier Message.

,m2 = 1

Not supported at this time.

,m3 = 1

Not supported at this time.

When you select Maxicode, you must format your data to conform to five fields. Field

Characters Allowed

1

Field Description

Default

5

ZIP code

None

2

4

ZIP code extension

None

3

3

Service class

999

4

3

Country code

840 (U.S.)

5

84

Message

None

You can format the data with or without inserting delimiters between the fixedlength fields, governed by the number of characters comprising the field. An example format without delimiters is shown below: Field

1

2

3

4

5 d3,068107317999840UP TO 84 CHARACTER MESSAGE 4630U-35

Note: Remember, the d3 command defines the data source in Program mode. Or, you can format data using the carat-delimiting field, as shown in the next example: Field

1

2

3

4

5

4630U-36

With this method of delimiting data, fields can be left out (as long as the carats remain) and the firmware will fill in the default as shown in the following example. With the carat-delimited format, you must completely fill in all fields, except the message field.

6-48

Page 165

Program Mode Commands

Field

1

3

2

6

5

4630U-37

In this example, the country code is left out, with the delimiting carat inserted. The printer firmware fills in the default value of 840 (USA).

Printing Mode 2 and Mode 3 Compatible Bar Codes IPL does not currently support Maxicode Modes 2 and 3; however, you can print a Mode 2 and 3 compatible bar code. The sample data format shown below prints a Mode 2 and 3 bar code on a printer that supports Maxicode Mode 2 and 3.

You must restructure the data to print a Mode 2 and 3 compatible bar code on the 4630 and 4830 printers:

The data fields in the sample format are described below: Field

Characters Allowed

1

Field Description

Default

5

ZIP code

None

2

4

ZIP code extension

None

3

3

Service class

999

4

3

Country code

840 (U.S.)

5

9

Header

None

6

75

Message

None

7

1

Data terminator

D

6-49

Page 166

4630 and 4830 Bar Code Label Printers User's Manual

For your printer to print Mode 2 and 3 compatible symbols, you must restructure the data: •

Insert the Mode 2 and 3 header immediately after the country code at the beginning of the secondary message.

•

Make the fields contiguous and fill in all fields.

•

Swap the order of the country code (field 4) and the service class (field 3).

•

Terminate your data with an uppercase D.

•

No control characters ( S or S) in the primary message.

R

G

HIBC Code 128 Syntax:

c16[,m1][,m2] The following three modifiers conform to Supplier Standard: c16,0

Select HIBC Code 128, primary format.

c16,1

Select HIBC Code 128, alternate primary format.

c16,2,m2

Select HIBC Code 128, secondary format. The linkage character comes from ,m2, which is the field identifier.

The following four modifiers conform to Provider Standard:

Default:

c16,3

Single format.

c16,4

First data format.

c16,5,m2

Select HIBC Code 128. Second data format. The linkage character comes from ,m2, which is the field identifier.

c16,6

Select HIBC Code 128. Multiple data format.

,m1 = 0

Bar Code Field, Create/Edit Purpose:

Use this command to edit or create a bar code field n.

Syntax:

Bn[,name] n values can range between 0 and 199. ,name is an optional field. The field can be up to eight ASCII characters (not counting the semicolon) and cannot start with a numeric character.

6-50

Page 167

Program Mode Commands

Default: Notes:

6 n=0 Parameters for the default field: Bar code = Code 39 Check digits = disabled

Height magnification = 50 Interpretive = disabled

Data length = 20 Data origin = Print mode

Prefix = none Ratio= 3 to 1

Field direction = 0° Field origin = 0,0

Width magnification = 1

Bitmap Cell Height for Graphic or UDF, Define Purpose:

Defines the height of a graphic or user-defined font.

Syntax:

yn n can range between 1 and 600. n is the number of rows for a graphic or font (bitmap). For outline fonts, n is the height of the base character in number of dots.

Default: Notes:

n=1 n = 10

Bitmap fonts and graphics Outline fonts

An error code (52) is generated for an invalid height.

Bitmap Cell Width for Graphic or UDF, Define Purpose:

Defines the maximum width for a graphic or any character in a font. Each character has a width within this amount, which should be at least as wide as the widest character in the font.

Syntax:

xn n can range between 0 and 599. n is the number of columns for the UDC, bitmap, or user-defined font. For outline fonts, n is the width of the base character in number of dots.

Default: Notes:

n=1 n = 10

Bitmap fonts and graphics Outline fonts

An error code (52) is generated if the width is invalid.

6-51

Page 168

4630 and 4830 Bar Code Label Printers User's Manual

Bitmap User-Defined Font, Clear/Create Purpose:

Use this command to clear or create a user-defined bitmap font set.

Syntax:

Tn[,name] n is the font ID number and can range from 3 to 6 and 8 to 19. ,name is an optional field. The field can be up to eight ASCII characters (not counting the semicolon).

Notes:

If font set n has already been defined, all previous characters in the font set are erased. An existing font cannot be edited, only recreated. To change any characters, the entire font set must be transmitted.

Border Around Human-Readable Text, Define Purpose:

Defines a border around a human-readable field.

Syntax:

bn n values range from 0 to 199.

Default: Notes:

n=0

No borders (black letters).

When n is greater than 0, the field prints white letters with an n dot size border surrounding the field.

Box Field, Create/Edit Purpose:

Use this command to access or create a box field n.

Syntax:

Wn[,name] n can range between 0 and 199. ,name is an optional field. The field can be up to eight ASCII characters (not counting the semicolon).

Default: Notes:

n=0 Parameters for the default field: Field origin = 0,0

Box length = 100

Field direction = 0°

Box height = 100 Box width = 1

6-52

Page 169

Program Mode Commands

6

Character Origin Offset, Define Purpose:

Defines the offset, to the right, of all characters in a font. If each character's width is defined in columns, with the first column numbered 0, then the origin of each character is at the column with the same number as n.

Syntax:

Xn n values can range between 0 and 599. For example, n = 2 shifts the character origins over two columns to the right.

Default: Notes:

n=0 For bitmap fonts only.

Character Rotation or Bar Code Ratio, Define Purpose:

Defines the character rotation for human-readable fields, or the bar code ratio for a bar code field.

Syntax:

rn For human-readable fields, n is the rotation: n=0 Horizontal n=1 90 degrees counterclockwise. For bar code fields, n is the ratio of the wide elements to the narrow elements: n=0 2.5 to 1 n=1 3.0 to 1 n=2 2.0 to 1

Default: Notes:

n=0 n=1

Human-readable field Bar code field

If the bar code width is odd and r0 is selected, r1 will be substituted.

Code 39 Prefix Character, Define Purpose:

Defines the prefix for a Code 39 field only.

Syntax:

p[n1][n2][n3][n4] n values can range between uppercase A to Z and 0 to 9.

Default: Notes:

No prefix The @ character clears all prefixes when entered as n1. Prefix characters do not appear in the interpretive field.

6-53

Page 170

4630 and 4830 Bar Code Label Printers User's Manual

Command Tables, Load Purpose:

Downloads a command table, with t as the command table identifier. This is followed by the nibblized command entries (c1 - cn) to be loaded into the table. To change an entry in the table, the entire table must be sent to the printer as a string of ASCII characters in hexadecimal form. Any entry not redefined retains its old value. The printer expects two hex digit bytes for every entry in the table.

Syntax:

Ct, command 1, command 2, ... command n t can range from 0 to 4. t is the command table identifier. Data must be nibblized ASCII characters ranging from 0 to 9 and A to F.

Notes:

New commands become effective after the printer is reset or the power is cycled. Command tables are listed later in this chapter.

Current Edit Session, Save Purpose:

Saves the current page, format, UDC, or UDF being edited. The printer remains in Program mode.

Syntax:

N

Field, Delete Purpose:

Deletes field n from the format.

Syntax:

Dn n values can range between 0 and 199.

Default: Notes:

6-54 n=0 The last field in a format cannot be deleted. If the current field is deleted, the field pointer points to the next field. If you delete a master field, you also delete all slave fields of that master field.