For the Intermec 4830

Page 151

Configuration Commands

6

Online/Offline on Power Up Purpose:

Selects the printer to be online or offline when it is turned on.

Syntax:

<SI>On n=0 n≠0

Default: Notes:

Printer is online on power up. Printer is offline on power up.

n=0 This command becomes effective after a printer reset or power up.

Postamble, Set Purpose:

Sets the postamble character to n.

Syntax:

<EOT>n n can be any ASCII character. When n = <NUL>, no postamble character is sent.

Default:

n = <NUL>

Preamble, Set Purpose:

Sets the preamble character equal to n.

Syntax:

<SOH>n n can be any ASCII character. When n = <NUL>, no preamble character is sent.

Default:

n = <NUL>

Print Speed, Set Purpose:

Sets the print speed in inches per second (ips).

Syntax:

<SI>Sn

Default:

4630 n must be from 20 to 80 (2.0 to 8.0 ips) in multiples of 5.

4830 n must be from 20 to 50 (2.0 to 5.0 ips) in multiples of 5.

n = 35, 4630 n = 25, 4830

6-35

Page 152

4630 and 4830 Bar Code Label Printers User's Manual

Printer Language, Select Purpose:

Selects the printer language.

Syntax:

<SI>ln n can be one of the following values:

Default: Notes:

0 = USA 1 = UK

4 = France 5 = Sweden

8 = 256 Characters 9 = Switzerland

2 = Germany 3 = Denmark

6 = Italy 7 = Spain

10 = Code Page 850 n=0 Only one language is used per print job. To print 256 Characters or Code Page 850, you must use a parralel interface or configure the host serial port for 8-bits per byte data transmission.

Self-Strip, Enable/Disable Purpose:

Turns the Self-Strip option on or off. The Self-Strip option must first be installed from the control panel.

Syntax:

<SI>tn n=0 n=1

Default: Notes:

Disables the Self-Strip option. Enables the Self-Strip option.

n=0 This command becomes effective after a printer reset or power up.

Top of Form, Set Purpose:

Sets the top-of-form (left margin) to n which is the distance, in 5 mil increments, from the label origin to its leading edge.

Syntax:

<SI>Fn n must be a number from -10 to 4000 in 5 mil increments. The negative values let you decrease the margin and print closer to the edge of the label.

Default:

6-36 n = 20

Page 153

Configuration Commands

6

TTR/Direct Thermal Media Grade, Select Purpose:

Selects the label stock to be used.

Syntax:

<SI>gn n=0 n=1

Default: Notes:

Direct thermal stock Thermal transfer stock n=0 This command becomes effective after a printer reset or power up.

Program Mode Commands The Program mode commands are used specifically for label format design and to download user-defined fonts and graphics. To set the printer to Program mode, send the following command string: <STX><ESC>P<ETX>

When creating or editing formats, the printer uses a field pointer to designate the field that is to be modified when the printer is in Program mode. In order to download commands in Program mode, you must specify the field to be changed. If you do not select a field, the pointer will continue to point to the last selected field until a different format or field is selected. New formats contain a default human-readable field numbered H0. New pages do not contain a default format. Note: Each string of commands must be preceded by the start of message character <STX>, and followed by the end of message character <ETX>. The semicolon (;) is the command terminator. All commands in Program mode must end with this terminator except the last command in a message. Parentheses {( )} and <LF> characters are ignored by the printer in Program mode. The following command descriptions explain the commands that are effective when the printer is in Program mode. The command descriptions are listed in alphabetical order.

6-37

Page 154

4630 and 4830 Bar Code Label Printers User's Manual

Bar Code, Select Type Purpose:

Selects a symbology for a bar code field.

Syntax:

cn[,m1][,m2][,m3] n can range from 0 to 16. ,m varies depending on the symbology you select.

Default: Notes:

n=0 Modifiers apply only to bar code symbologies. For more information on bar code symbologies, please refer to The Bar Code Book by Roger Palmer (Intermec P/N 051241). Use the following table to find the correct bar code for your format. Value

Symbology

Value

Symbology n=0

Code 39 n=8

HIBC Code 39 n=1

Code 93 n=9

Code 16K n=2

Interleaved 2 of 5 n = 10

Code 49 n=3

Code 2 of 5 n = 11

POSTNET n=4

Codabar n = 12

PDF417 n=5

Code 11 n = 13

Code One n=6

Code 128 n = 14

Maxicode n=7

UPC/EAN Codes n = 16

HIBC Code 128

The following pages contain detailed descriptions of the different symbologies and the parameters that you can set for each.

6-38

Page 155

Program Mode Commands

6

Code 39 Syntax:

c0[,m] The 4630 and 4830 printers support standard Code 39, full ASCII Code 39, and 43 character Code 39. If you enter <ESC><SPACE> as data, the start and stop characters are printed. c0,0

Select Code 39. No check digit.

c0,1

Select Code 39. Printer enters check digit.

c0,2

Select Code 39. Host enters check digit and printer verifies.

c0,3

Select full ASCII Code 39. No check digit.

c0,4

Select full ASCII Code 39. Printer enters check digit.

c0,5

Select full ASCII Code 39. Host enters check digit and printer verifies.

c0,6

Select 43 character Code 39. No check digit.

c0,7

Select 43 character Code 39. Printer enters check digit.

c0,8

Select 43 character Code 39. Host enters check digit and printer verifies.

Default:

,m = 0

Syntax:

c1

Code 93

Interleaved 2 of 5 Syntax:

c2[,m] The printer adds a zero to character strings that are odd in length.

Default:

c2,0

Select Interleaved 2 of 5. No check digit.

c2,1

Select Interleaved 2 of 5. Printer enters check digit.

c2,2

Select Interleaved 2 of 5. Printer enters check digit.

,m = 0

6-39

Page 156

4630 and 4830 Bar Code Label Printers User's Manual

Code 2 of 5 Syntax:

c3[,m] c3,0

Select Code 2 of 5. 3-bar start/stop code.

c3,1

Select Code 2 of 5. 2-bar start/stop code.

Default:

,m = 0

Syntax:

c4[,m]

Codabar Valid start/stop characters range from A to D and from a to d. You can define them as part of the bar code field or you can download them as part of the print data. Start/stop characters sent down with printer data override the characters defined by the bar code field. c4,0

Select Codabar. Host enters start/stop codes and printer verifies.

c4,1,x,y

Select Codabar. Printer enters start code x and stop code y. x and y can range from A to D.

Default:

,m = 0

Syntax:

c5[,m]

Code 11

Default:

6-40 c5,0

Select Code 11. Printer enters 2 check digits.

c5,1

Select Code 11. Printer enters 1 check digit.

c5,2

Select Code 11. Host enters 2 check digits and printer verifies.

c5,3

Select Code 11. Host enters 1 check digit and printer verifies.

,m = 0

Page 157

Program Mode Commands

6

Code 128 Syntax:

c6[,m1][,m2] UCC-128 serial shipping container code automatically starts in subset C with a <FNC1>. It is a fixed length version of Code 128 requiring you to enter 19 numeric characters. The printer forces the first two characters to zero.

Default:

c6,0,0

Code 128, keep parentheses and spaces.

c6,0,1

Code 128, ignore parentheses and spaces in the bar code but keep parentheses and spaces in the interpretive field.

c6,1,0

Select UCC-128 Serial Shipping Container Code.

c6,1,1

Select UCC-128 Serial Shipping Container Code and keep parentheses and spaces in the interpretive field.

,m1 = 0 (Code 128) ,m2 = 0 (keep parentheses and spaces)

UPC/EAN Syntax:

c7[,m1][,m2] c7,0,m2

Select UPC/EAN Codes. Printer enters check digit and flag 1 enable.

c7,1,m2

Select UPC/EAN Codes. Printer enters check digit and flag 1 disabled.

c7,2,m2

Select UPC/EAN Codes. Host enters check digit and printer verifies flag 1 enabled.

c7,3,m2

Select UPC/EAN Codes. Host enters check digit and printer verifies. flag 1 disabled.

Use ,m2 to select the following UPC/EAN codes:

Default:

0 variable length

5

UPC Version D1

1

EAN 8

6

UPC Version D2

2

EAN 13

7

UPC Version D3

3

UPC Version A

8

UPC Version D4

4

UPC Version E

9

UPC Version D5

,m1 = 0 ,m2 = 0

6-41

Page 158

4630 and 4830 Bar Code Label Printers User's Manual

Notes:

The variable length option (,m2) selects the UPC/EAN version by the number of characters in the data field. The number of data characters and check characters allowed for each version are: EAN 8

7 data + 1 check character

EAN 13

12 data + 1 check character

UPC version A

11 data + 1 check character

UPC version E

6 data + 1 check character

UPC version D1

13 data + 1 check character

UPC version D2

18 data + 2 check characters

UPC version D3

22 data + 2 check characters

UPC version D4

25 data + 3 check characters

UPC version D5

29 data + 3 check characters

Use " " to delimit the bar code data from the supplemental data. Data to the right of " " is supplemental data; data to the left is bar code data. You can add the two- or five-digit supplemental data to any version of the UPC/EAN code. The flag 1 option only applies to EAN 8, EAN 13, and UPC version A. For EAN 13, enabling the flag 1 option prints the first character of the bar code interpretive. For EAN 8 and UPC version A, enabling the flag 1 option moves the first and last character of the bar code interpretive outside of the guard bars.

HIBC Code 39 Syntax:

c8[,m1][,m2] The following three modifiers conform to Supplier Standard: c8,0

Select HIBC Code 39. Primary format.

c8,1

Select HIBC Code 39. Alternate primary format.

c8,2,m2

Select HIBC Code 39. Secondary format. The linkage character comes from ,m2, which is the field identifier.

The following four modifiers conform to Provider Standard:

Default:

6-42 c8,3

Single format.

c8,4

First data format.

c8,5,m2

Select HIBC Code 39. Second data format. The linkage character comes from ,m2, which is the field identifier.

c8,6

Select HIBC Code 39. Multiple data format.

,m1 = 0

Page 159

Program Mode Commands

6

Code 16K Syntax:

c9

Syntax:

c10

Syntax:

c11

Notes:

POSTNET uses the height (h) and width (w) commands in the same way as a font. Other symbologies use “h” to specify the bar height and “w” to specify the narrow bar width. POSTNET uses “h” and “w” to magnify the base character cell. Each character cell is 13 dots high by 22 dots wide. The default width and height magnification for POSTNET is 2 x 2, resulting in a symbology sized according to the POSTNET specification.

Syntax:

c12[,[m1][,m2][,m3]]

Default:

,m1 = 0

Printer selects the number of columns needed to create a symbol that is as close to square as possible. The range for m1 is 0 to 30.

,m2 = 9

The printer automatically selects the error correction level based on the amount of data. The range for ,m2 is 0 to 9.

,m3 = 0

Truncating disabled. The values for ,m3 are 0 and 1.

Code 49

POSTNET

PDF417

Notes:

PDF417 is a stacked 2D symbology that provides the ability to scan across rows of code. Each row consists of start/stop characters, row identifiers, and symbol characters, which consist of four bars and four spaces each and contain the actual data. This symbology uses error correction symbol characters appended at the end to recover loss of data.

Selecting the Number of Columns Set ,m1 to zero to have the printer select a height magnification that is three times the width magnification for the symbol. The specifications of PDF417 recommend these magnification values for creating a symbol that you can scan easily.

6-43

Page 160

4630 and 4830 Bar Code Label Printers User's Manual

Selecting an Error Correction Level The level of error correction that works best for your data depends on the amount of characters in your symbols. If you decide to select your own error correction level, you need to estimate the number of characters since they are formed by compressing the raw data you send to the printer. In general, 1.8 alphanumeric characters generate one symbol character. If you are using numeric data, 2.9 digits generate one data symbol character. Intermec recommends that you leave the error correction level at the default setting of 9. This setting lets the printer select a level, between level 2 and level 5, that provides the most efficient error correction of your data. The printer bases the level selection on the number of symbol characters your data generates. The following table shows the m2 values (error correction levels), the recommended data amount that you should use for each level, and the number of error correction characters the level generates.

,m2 0 1 2 3 4 5 6 7 8 9

Recommended Data Amount * * 1 - 40 41 - 160 161 - 320 321 - 863 † † † ‡

Error Detection Characters 2 4 8 16 32 64 128 256 512

(error detected, no recovery)

*

You should only use ,m2 values of 0 and 1 if your labels do not have enough space for more error correction characters. These values are generally not recommended.

†

The printer reserves ,m2 values of 6, 7, and 8 for special applications where the symbol is subject to damage and requires a higher level of error correction.

‡

An ,m2 value of 9 lets the printer set m2 to the recommended value for each symbol based on the number of characters. An m2 value of 9 is the default setting.

Setting the Truncate Flag The truncate flag determines if the symbol is printed in truncated form. A trucated symbol prints without right row indicators and with only a onemodule wide stop character. To minimize errors and maintain the best reading performance, Intermec recommends that ,m3 be set to 0.

6-44