Page 221

HelvC NugFont

Co d e 39 Printer Commands

7

More About PDF 417 2D symbols encode data by compressing it in different amounts. Therefore, these values should be used as guidelines. The exact data capacity varies with the actual data being encoded. Full ASCII

Alphanumeric

Numeric

1108

1850

2725

Using m1 to Select Number of Columns When you select the default for m1 (0), the printer selects a height magnification that is three times the width magnification. The specifications of PDF 417 recommend these magnification values for creating a symbol that you can easily scan.

Using m2 to Select an Error Correction Level The level of error correction that works best for your data depends on the amount of characters in your symbols. If you decide to select your own error correction level, you will need to estimate the number of characters since they are formed by compressing the raw data you send to the printer. In general, 1.8 alphanumeric characters generate one symbol character. If you are using numeric data, 2.9 digits generate one data symbol character. Intermec recommends that you leave the error correction level at the default setting of 9. This default setting lets the printer select a level, between level 2 and level 5, that provides the most efficient error correction of your data. The level selection is based on the number of symbol characters generated by your data.

Using m3 to Set the Truncate Flag m3 is a truncate flag that indicates whether to print the symbol in truncated form. If truncated, the symbols are printed without right row indicators and with only a one-module wide stop character. To minimize errors and maintain the best reading performance, Intermec recommends that you leave m3 equal to 0. Setting the truncate flag loses the symbol redundancy. Since row indicators are not error-corrected, elimination of one set of them increases your chances of losing row identification.

More About Code One Code One modules must be square. Therefore, when you define a field for Code One, you only need to enter one value for both the height and width magnification. If you enter more than one value, the printer uses the last value for both height and width and ignores all previously entered magnification values. If no value is entered, the printer uses the default value.

7-77

Page 222

4400 Bar Code Label Printer User’s Manual

You can use groups of Code One symbols to encode data so separate symbols can be scanned more efficiently. When you scan a group of symbols, the scanner accumulates the data from all members of the group and transmits the data as if it came from a single symbol.

Using m1 to Select a Code One Version It is important that you select the correct version of Code One for the data you are encoding. If you try to encode an inappropriate amount of data or an incorrect type of data in the wrong version, your symbol may not print. If your data lengths vary greatly for different labels, or if you are not sure which symbology to select, you can select the variable Code One version (set m1=0). This lets the printer select the correct version of Code One (from version A to version H) based on the data length. If your data lengths are known and consistent, or if the printer always chooses the same version, you should manually select the Code One version to save printer memory. When you print Code One symbols, you may notice that part of your symbol contains no data. Each version of Code One has a fixed size, and the version that is large enough to accommodate all your data may be larger than you need. This does not mean you should use a version of a smaller size, because if it is too small for your data to fit, the symbol will not print.

More About Maxicode When selecting Maxicode, you have to format your data into the following five fields: Field

Number of Characters

Description of field

Default

1 five

Zip code

None

2 four

Zip code extension

None

3 three

Service class

999

4 three

Country code

840 (U.S.)

5

84

Message

None

Fixed-length fields If you will always fill in all fields, you can string the characters together without a delimiter. Carat-delimited fields If you may want to use the default value for a field instead of typing it in, place carats (^) between each field. To use the default value for a field, do not place any characters between the carats.

7-78

Page 223

HelvC NugFont

Co d e 39 Printer Commands

7

Test and Service Mode Command Descriptions The following table gives descriptions of the Test and Service mode commands. To enter Test and Service mode from Print mode, send <ESC>T from the host terminal. Note: All commands in Test and Service mode end with a semicolon (;) except the last command in a message. Command Code

Summary

Description

A;

Transmit Ambient Temperature

Transmits the ambient temperature sensor A/D output back to the host. The value ranges from 00 to 255.

B;

Printhead Resistance Test

Causes the printer to begin the printhead resistance test. The printer will respond with the ASCII character string “pass” or “fail.”

C;

Print Pitch Label

Causes the printer to print the pitch label.

D;

Reset Printer Configuration

Sets the printer configuration to the factory defaults. When you exit Test and Service mode after sending this command, the printer performs a warm boot (it resets).

G;

Transmit Transmissive Sensor Value

Transmits the label gap transmissive sensor A/D output back to the host. Value ranges from 00 to 255.

L;

Transmit Paper Path Open Sensor Value

Transmits the paper path open switch value back to the host. A value of 0 indicates the paper path is open and a value of 1 means it is closed.

M;

Transmit Reflective Sensor Value

Transmits the label mark reflective sensor A/D output back to the host. The value ranges from 00 to 255.

P;

Transmit Printhead Temperature Sensor Value

This command transmits the printhead thermistor A/D output back to the host. Range of the value is 00 to 255.

Q;

Print Quality Label

Causes the printer to print out the print quality program and model number label.

R;

Exit Test and Service

Causes the printer to exit Test and Service mode.

S;

Transmit Printhead Resistance Values

Transmits the average, maximum, and minimum printhead dot resistance value back to the host. Each value is a numeric data string separated by a comma.

T;

Transmit Label Taken Sensor Value

Transmits the label taken sensor A/D output back to the host. The value can range from 00 to 255.

U;

Transmit 12 Volt Supply Value

Transmits the 12V supply A/D output back to the host. The range of the value is 00 to 255.

V;

Transmit 24 Volt Supply Value

Transmits the 24V supply A/D output back to the host. The range of the value is 00 to 255.

7-79

Page 224

4400 Bar Code Label Printer User’s Manual

Printer Functional Boundaries Every printer feature has a functional limit that assumes unlimited common memory. Since several functions may compete for common memory, the memory limit may be reached before the functional limit is reached. For example, even though you have a functional limit of 20 formats, you may run out of memory before you can store 20 formats if you have downloaded several large graphics. In cases like this, you may want to restructure your data or purchase additional printer memory.

7-80

Parameter

Functional Limit

Bar Code Height

50 inches

Bar Code Narrow Bar Multiplier

50

Characters in a Field (Including Control Characters and Delimiters)

200

Characters in a Field Name

8

Field Data Offset

9999

Fields in a Format

200

Font Character Size

3 sq. inches

Formats

20 including default

Formats in a Page

26

Graphic Size

4 sq. inches

Graphics

100

Image Bands

10

Increment or Decrement Skip Value

9999

Languages

8 per seven-bit character set; 1 per eight-bit character set

Length or Width of a Line or Box

9999 dots (50 inches)

Pages

10 including default

Quantity or Batch Size

9999

Slaves to a Field

20

User-Defined Fonts

16

Page 225

8 Special Procedures

Page 226

This page is a scan with no text; see it in the PDF.

Page 227

Special Procedures

8

This chapter contains instructions for the following special procedures: •

Setting up security levels.

•

Copying the entire RAM contents from one printer to another (cloning).

•

Copying selected formats, fonts, graphics, or pages from one printer to another.

•

Installing options, such as the cutter or self-strip if you unload them during memory reset.

About Security Levels If you want to restrict access to certain menus in the printer, you can do so by setting a security level. Restricting access not only prevents unauthorized tampering with printer settings, but also eliminates the number of choices you scroll through when selecting menus and options.

Security Level Descriptions The following table shows the restrictions imposed by different security levels. Security Setting

Menus Allowed

Level 0 (default)

Allows access to all control panel menus.

Level 1

Operator and Configuration menus.

Level 2

Operator menu only. The audible alarm beeps (if enabled) at an attempt to scroll to other menus.

Level 3

Access not allowed to any of the control panel menus.

Note: Regardless of the security level setting, you can switch between online and offline, reload media, and open the printer.

Setting a Security Level When setting a security level, you can always access restricted menus when necessary. Restricting menus reduces the choices when using the control panel. To set a security level 1. Start at the OFFLINE READY screen (press [ONLINE/OFFLINE] if necessary). 2. Press [MENU]. Then press [↑] or [↓] until the display shows the following: OFFLINE INSTALL MENU

8-3

Page 228

4400 Bar Code Label Printer User’s Manual

3. Press [SELECT]. Then press [↑] or [↓] until the display shows the following: INSTALL MENU SECURITY

4. Press [SELECT]. The display shows the current Security level with an asterisk (*) such as in the example below: SECURITY LEVEL 0*

5. Press [↑] or [↓] until you see the security level you want, and then press [ENTER] to move the asterisk (*) to that level as in the example below: SECURITY LEVEL 1*

6. Press [CONTINUE] to return to the OFFLINE READY display.

Bypassing Security Levels You can bypass a security level if you need to access a restricted menu from the control panel. To bypass a security level 1. Turn the printer off. 2. Hold down the [FEED/RELOAD] key while you turn the printer on. This procedure sets security level 0, which allows access to all menus.

Cloning Cloning is the process of copying the RAM contents from one printer (the sender printer) to another printer (the receiver printer). By programming and configuring just one printer and then cloning its RAM to other printers, you can configure a large number of printers in much less time than it would take to program them individually. The clone command copies the following RAM contents to the receiver printer: •

Printer configuration data

•

Label formats, page formats, fonts, graphics and User-Defined protocol or command tables

The cloning procedure consists of connecting the main serial ports of two printers together with an RS-232 null modem cable. Control panel commands are then used to designate each printer as either a sender or receiver. The control panel on the sender printer is used to execute the clone command.

8-4

Page 229

Special Procedures

8

Keep in mind these cloning limits: •

You can only clone from like printer to like printer. You cannot clone an 8636 or 8646 printer to a 4400 printer, even when the 4400 printer is running in the 86XX emulation mode. The reverse is also true.

•

The sender and receiver printers must be running the same firmware revision.

•

The sender and receiver printer must have exactly the same amount of static RAM installed.

•

If you are cloning printer configuration parameters to printers that are used in a multi-drop environment, be sure to assign each printer a unique device address when cloning is complete.

If you are not sure of your printer’s RAM configuration, firmware revision, or setup configuration, print a configuration test label.

Connecting the Printers for Cloning The first step to cloning involves connecting the sender printer (the printer containing the information you want to copy) to the receiver printer (the printer that is to receive the information). To connect the sender and receiver printers 1. Obtain an RS-232 null modem serial cable with a 25-pin “D” style subminiature plug on each end (Intermec Part No. 048668). 2. Plug one end of the cable into the serial port on the rear panel of sender printer. 3. Plug the other end of the cable into the serial port on the rear panel of receiver printer.

Preparing the Receiver Printer Note: Cloning will erase any data stored in the receiver. 1. Start at the OFFLINE READY display. OFFLINE READY

2. Press [MENU] to enter the main menu. The display shows: OFFLINE OPERATOR MENU

8-5

Page 230

4400 Bar Code Label Printer User’s Manual

3. Press [↑] or [↓] until the display shows: OFFLINE SERVICE MENU

4. Press [SELECT] to enter the Service menu. The display shows: SERVICE MENU PRINT PAGE

5. Press [↑] or [↓] until the display shows: SERVICE MENU CLONING

6. Press [SELECT]. The display shows: CLONING SENDER

7. Press [↑] or [↓] until the display shows: CLONING RECEIVER

8. Press [ENTER]. The display shows: RECEIVING

Preparing the Sender Printer 1. Switch on the printer you are designating as the sender and start at the OFFLINE READY display: OFFLINE READY

2. Press [MENU] to enter the Main menu as shown below: OFFLINE OPERATOR MENU

3. Press [↑] or [↓] until the display shows: OFFLINE SERVICE MENU

4. Press [SELECT]. The display shows: SERVICE MENU PRINT PAGE

5. Press [↑] or [↓] until the display shows: SERVICE MENU CLONING

8-6