Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 22 of 32

4400 Bar Code Label Printer User's Manual, pages 211 to 220

Pages 211 to 220 of 318

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 4400

Page 211

HelvC NugFont

Co d e 39 Printer Commands

7

Protocol Commands (t=4) The following list contains the protocol codes in the order they must be downloaded. Command Description

Command Characters

Hex Value

SELECT IN

GS

1D

POLL IN

FS

1C

RES IN

EOT

04

REQ IN

ENQ

05

SOM IN

STX

02

EOM IN

ETX

03

AFF IN

ACK

06

NEG IN

NAK

15

DLE IN

DLE

10

XON IN

DC1

11

XOFF IN

DC3

13

SELECT OUT

GS

1D

POLL OUT

FS

1C

RES OUT

EOT

04

REQ OUT

ENQ

05

SOM OUT

STX

02

EOM OUT

ETX

03

AFF OUT

ACK

06

NEG OUT

NAK

15

DLE OUT

DLE

10

XON OUT

DC1

11

XOFF OUT

DC3

13

Proto-Cmd 1

ENQ

05

Proto-Cmd 2

VT

0B

Timeout on EOM ACK

20 (ms) (Range: 0 - 255)

14

7-67

Page 212

4400 Bar Code Label Printer User’s Manual

Communication Protocol Characters The following table shows the characters available for different protocols. Refer to the protocol you are using for your system. Protocol Characters

Standard

Polling Mode D

Multi-Drop

Select In

GS

GS

Poll In

FS

FS

Reset In

EOT

EOT

Request for Acknowledgment In

XON/XOFF

ENQ

ENQ

Start of Message In

STX

STX

STX

STX

End of Message In

ETX

ETX

ETX

ETX

ACK

ACK

Acknowledgment In Negative Acknowledgment In Data Line Escape In

DLE

NAK

NAK

DLE

DLE

XON In

DC1

XOFF In

DC3

DLE

Select Out

GS

Poll Out

FS

Reset Out

EOT

Request for Acknowledgment Out

ENQ

EOT

ENQ

Start of Message Out

STX

STX

End of Message Out

ETX

ETX

Acknowledgment Out

ACK

ACK

NAK

NAK

DLE

DLE

20 (DEC)

20(DEC)

Negative Acknowledgment Out

NAK

Data Line Escape Out

DLE

DLE

XON Out

DC1

XOFF Out

DC3

Status Enquiry In

ENQ

ENQ

Status Dump In

VT

VT

Timeout on EOM ACK

7-68

Page 213

HelvC NugFont

Co d e 39 Printer Commands

7

Fonts The following table accompanies the command description for Select Type of Graphic Font or Bar Code (cn,m1,m2,m3;) for selecting fonts. Fonts may be selected in the following manner: Font Selection

Font Description c0

7x9 standard c1

7x11 OCR c2

10x14 standard c3-c6

User-defined fonts c7

5x7 standard c8-c19

User-defined fonts c20

8 point standard c21

12 point standard c22

20 point standard c23

OCR A c24

OCR B size 2 c25

Outline font c30

6 point bold c31

8 point bold c32

10 point standard c33

10 point bold c34

12 point bold c35

16 point standard c36

16 point bold c37

20 point bold c38

24 point standard c39

24 point bold c40

30 point bold c41

36 point bold

7-69

Page 214

4400 Bar Code Label Printer User’s Manual

Bar Codes The following table accompanies the command description for Select Type of Graphic, Font, or Bar Code (cn[,m1][,m2][,m3]) for selecting bar codes. The bar codes listed below may be selected as shown. Optional modifiers are denoted by m. Bar Code Selection

Bar Code Description c0 ,m

Selects Code 39. Select m to specify parameters as listed below. The default for m is 0. c0,0

Selects 8646 compatible Code 39. No check digit.

c0,1

Selects 8646 compatible Code 39. Printer enters check digit.

c0,2

Selects 8646 compatible Code 39. Host enters check digit and printer verifies.

c0,3

Selects full ASCII Code 39. No check digit.

c0,4

Selects full ASCII Code 39. Printer enters check digit.

c0,5

Selects full ASCII Code 39. Host enters check digit and printer verifies.

c0,6

Selects 43 character Code 39. No check digit.

c0,7

Selects 43 character Code 39. Printer enters check digit.

c0,8

Selects 43 character Code 39. Host enters check digit and printer verifies.

c1

Selects Code 93.

c2 ,m

Selects Interleaved 2 of 5. Select m to specify parameters as listed below. The default for m is 0. c2,0

No check digit.

c2,1

Printer enters check digit.

c2,2

Host enters check digit and printer verifies. Selects Code 2 of 5. Select m to specify parameters as listed below. The default for m is 0.

c3 ,m c3,0

Selects 3-bar start/stop code.

c3,1

Selects 2-bar start/stop code. Selects Codabar. Select m to specify parameters as listed below. Default for m is 0.

c4 ,m

7-70 c4,0

Host enters start/stop codes and printer verifies.

c4,1,x,y

Printer enters start code x and stop code y. x and y can range from A to D.

Page 215

HelvC NugFont

Co d e 39 Printer Commands

7

Bar Codes (continued) Bar Code Selection

Bar Code Description c5 ,m

Selects Code 11. Select modifiers to specify parameters as listed below. The default for m is 0. c5,0

Printer enters two check digits.

c5,1

Printer enters one check digit.

c5,2

Host enters two check digits. Printer verifies.

c5,3

Host enters one check digit. Printer verifies. Selects Code 128.

c6,m1,m2

In 86XX Emulation mode, you can print the Function 1 character by entering <SUB>1. In Advanced mode, you can print the Function 1 by entering <SUB><SUB>1. You can print the characters for Function 2, 3, and 4 in the same way. UCC-128 serial shipping container code automatically starts in subset C and a <FNC1>. It is a fixed length version of Code 128 requiring you to enter 19 numeric characters. The printer forces the first two characters to zero. The default for ,m1 = 0 (Code 128O. The default for ,m2 = 0 (keep parentheses and spaces).

c7,m1,m2 c6,0,0

Code 128, keep parentheses and spaces.

c6,0,1

Code 128, ignore parentheses and spaces in the bar code but keep them in the interpretive field.

c6,1,0

Select UCC-128 Serial Shipping Container Code.

c6,1,1

Select UCC-128 Serial Shipping Container Code and keep parentheses and spaces in interpretives. Selects UPC/EAN with m1 as shown below. Default for m1 is 0. The variable length option selects the UPC/EAN version by the number of characters in the data field. The number of data characters and check characters allowed for each version are: EAN 8 EAN 13 UPC version A UPC version E UPC version D1 UPC version D2 UPC version D3 UPC version D4 UPC version D5

7 data + 1 check character 12 data + 1 check character 11 data + 1 check character 6 data + 1 check character 13 data + 1 check character 18 data + 2 check characters 22 data + 2 check characters 25 data + 3 check characters 29 data + 3 check characters

Use a “.” to delimit the bar code data from the supplemental data. Data to the right of the “.” is supplemental data; data to the left is bar code data. You can add the two- or five-digit supplemental to any version of the UPC/EAN code.

7-71

Page 216

4400 Bar Code Label Printer User’s Manual

Bar Codes (continued) The flag 1 option only applies to EAN 8, EAN 13, and UPC version A. For EAN 13, enabling the flag 1 option prints the first character of the bar code interpretive. For EAN 8 and UPC version A, enabling the flag 1 option moves the first and last character of the bar code interpretive outside of the guard bars. c7,0 ,m2

Select UPC/EAN Codes. Printer enters check digit and flag 1 enable.

c7,1 ,m2

Select UPC/EAN Codes. Printer enters check digit and flag 1 disabled.

c7,2 ,m2

Select UPC/EAN Codes. Host enters check digit and printer verifies. Flag 1 enabled.

c7,3 ,m2

Select UPC/EAN Codes. Host enters check digit and printer verifies. Flag 1 disabled. Use ,m2 to select the UPC/EAN codes listed below. Default is 0.

0 variable length 1 EAN 8 2 EAN 13 3 UPC Version A 4 UPC Version E 5 UPC Version D1 6 UPC Version D2 7 UPC Version D3 8 UPC Version D4 9 UPC Version D5 Selects HIBC Code 39 with ,m1 as shown below. Default for ,m1 is 0.

c8,m1,m2

The next three modifiers conform to Supplier Standard: c8,0

Selects HIBC Code 39. Primary format.

c8,1

Selects HIBC Code 39. Alternate primary format.

c8,2,m2

Selects HIBC Code 39. Secondary format. The linkage character comes from ,m2 (which is the field identifier). The next four modifiers conform to Provider Standard:

c8,3

Single format.

c8,4

First data format.

c8,5,m2

Selects HIBC Code 39. Second data format. The linkage character comes from ,m2 (which is the field identifier).

c8,6

Selects HIBC Code 39. Multiple data format.

c9

Selects Code 16K.

c10

Selects Code 49.

c11

Selects POSTNET.

7-72

Page 217

HelvC NugFont

Co d e 39 Printer Commands

7

Bar Codes (continued) Bar Code Selection

Bar Code Description c12,m1,m2,m3

Selects PDF 417. The modifiers and their defaults are described below. m1 = 0

Printer selects the number of columns needed to create a symbol that is as close to square as possible.

m2 = 9

The printer automatically selects the error correction level, based on the amount of data.

m3 = 0

Truncating disabled. m1 selects the number of columns of data characters. The range is 0 to 30 and the default is 0. If you select zero, the printer provides the number of columns needed to create a symbol that is as close to a square as possible. Note: When you select zero, the printer selects a height magnification that is three times the width magnification. The specifications of PDF417 recommend these magnification values for creating a symbol that you can scan easily. m2 selects the level of error correction as shown in the table below. Each level provides a certain number of error detection characters, which can detect and recover a specific number of faulty characters.

m2

Recommended Data Amount

Error Detection Characters

0* 1* 2 3 4 5 6† 7† 8† 9‡

* * 1-40 41-160 161-320 321-863 863+ 863+ 863+ (default)

2 (error detected, no recovery) 4 8 16 32 64 128 256 512

* Not recommended. Should only be used if your labels are too small to allow more characters. †Not recommended. Reserved for special applications. ‡The printer sets the recommended value for each symbol. m3 is a truncate flag. The values for m3 are 0 to disable truncating and 1 to enable truncating.

7-73

Page 218

4400 Bar Code Label Printer User’s Manual

Bar Codes (continued) Bar Code Selection

Bar Code Description c13,m1,m2,m3

Selects Code One. The modifiers are described briefly below and the defaults are shown. m1 = 0

Code One version, variable.

m2 = 1

First position in the group.

m3 = 1

Total number of symbols in the group is one symbol. m1 determines the Code One version, and the values are listed below. Code One, variable length (Autoselects from Code One version A to Code One version H)

c13,0,m2,m3 c13,1,m2,m3

Code One version A c13,2,m2,m3

Code One version B c13,3,m2,m3

Code One version C c13,4,m2,m3

Code One version D c13,5,m2,m3

Code One version E c13,6,m2,m3

Code One version F c13,7,m2,m3

Code One version G c13,8,m2,m3

Code One version H c13,9,m2,m3

Code One version S10 c13,10,m2,m3

Code One version S20 c13,11,m2,m3

Code One version S30 c13,12,m2,m3

Code One version T16 c13,13,m2,m3

Code One version T32 c13,14,m2,m3

Code One version T48

Note: The data lengths in the following table are approximations of the maximum amount of data for each version of Code One. The data is compressed before it is encoded, which shortens its length from the amount you send. If you select the variable length, the printer may select a Code One version that is smaller than the one listed next to your data length.

7-74

Page 219

HelvC NugFont

7

Co d e 39 Printer Commands

Bar Codes (continued) The following table shows the data lengths for each Code One version.

m1 Value

Code One Type

0 variable*

1

Full ASCII

Alphanumeric

Numeric

A

10

13

22

2

B

19

27

44

3

C

44

64

104

4

D

91

135

217

5

E

182

271

435

6

F

370

553

886

7

G

732

1096

1755

8

H

1480

2218

3550

9

S10

†

†

6

10

S20

†

†

12

11

S30

†

†

18

12

T16

10

13

22

13

T32

24

34

55

14

T48

38

55

90

*The printer selects the correct Code One version, between A and H. †Supports numeric data only.

m2 and m3 define symbols that are part of a group. m2 is the position of the current symbol in the group, and m3 is the total number of symbols in the group. For example, a setting of ,m2,m3 to ,2,5 indicates that the current symbol definition is the second in a group of five. Both m2 and m3 have a range from 1 to 15, with a default of 1. Make sure m2 is never greater than m3. Note: The printer does not check to ensure all positions of a group are defined. For example, if m3 is set to 5, and only three positions are defined, the printer will print three symbols that are encoded to be part of a group of five symbols. When these symbols are scanned, the scanner will wait for all five symbols and will not be able to transmit the data.

7-75

Page 220

4400 Bar Code Label Printer User’s Manual

Bar Codes (continued) Bar Code Selection

Bar Code Description c14,m1,m2,m3

Selects Maxicode. Default for m1 is 0. m2 and m3 are not currently supported. c14,0

Structured Carrier Message. Selects HIBC Code 128 with m1 as shown below. Default for m1 is 0.

c16,m1,m2

The next three modifiers conform to Supplier Standard: c16,0

Primary format.

c16,1

Alternate primary format.

c16,2,m2

Secondary format. The linkage character comes from m2 (which is the field identifier). The next four modifiers conform to Provider Standard:

c16,3

Single format.

c16,4

1st data format.

c16,5,m2

2nd data format. The linkage character comes from m2 (which is the field identifier).

c16,6

Multiple data format.

More About Printing 2D Symbologies When you encode and print 2D symbologies, use the following guidelines:

7-76

•

Select a symbol size that can encode all the data being downloaded. If you select one that is too small, then the symbol will not print. If you do not know the amount of data you are sending, allow space for the largest possible amount.

•

In Program mode, the data length is confined to 255 characters. This means that the d3 command, which is used to define data in Program mode, cannot be followed by more than 255 characters. To send more than 255 characters, you must send the data in Print mode using the d0 command.

•

To send more than 255 characters in Print mode with the d0 command, you must separate the data into packets of 255 characters. These packets are separated by <STX> and <ETX>.

•

The maximum amount of data that can be entered into a field with the d0 command is 3550 characters. However, if you are declaring d0 fields to be much larger than necessary, you may run out of memory, especially if you use the maximum value of 3550. To avoid wasting memory, estimate the largest amount of data you will send and use a value that is close to that amount.