Page 35
7 MaxiScan Connexion System (option) MCS connection box The MaxiScan Connexion System (MCS) can be used to connect the Maxiscan 3100 to a host computer, power supply and synchronization device. The MCS box is an option (P/N 0-531029-06).
SCANNER
POWER SUPPLY
MAXISCAN CONNEXION SYSTEM
MCS Port
Type
Connect to
Remarks
S can n er
15-pin subD male
MaxiScan 3100
Pow er supply
9-pin subD male
External power supply
7-25 V 2.5 Watt full-wave rectified unregulated power
H o st
15-pin subD female
Host computer
· RS-232 C (standard configuration) · Current Loop (requires MCS) Each host system interface is software programmable and requires a different cable
Synchros
9-pin subD female
I/O synchronization device
Input synchronization - reading can be triggered by an external cell, automatic machine, electrical control device Outp ut s ync hro ni za ti o n - a n e xte rna l d e vi ce (swi tch, a la rm, i nd i ca to r li g ht) c a n b e tr i g g e r e d b y a g o o d r e a d o r unsuccessful read as required
MaxiScan 3100 - Installation Guide
35
Page 36
7 MaxiScan Connection System
Scanner port RX TX CTS RTS SI+
SI- SO+ SO-
1
6
2
3
4
5
7
8
15-pin subD male connector
9
10
11
12
13
14
15
CHASSIS GND 7-25 VDC PWR GND
Pin
36
7-25 VDC
Function
1
Receive data (RS-232 C)
2
Transmit data (RS-232 C)
3
Clear to send (RS-232 C)
4
Request to send (RS-232 C)
5
Positive synchronization input (SI+)
6
Negative synchronization input (SI-)
7
Positive synchronization output (SO+)
8
Negative synchronization output (SO-)
9
Not connected
10
Power in (7 to 25 VDC 2.5 Watt unregulated)
11
Power ground
12
Shield
13
Power ground
14
Power in (7 to 25 VDC 2.5 Watt unregulated)
15
Not connected
MaxiScan 3100 - Installation Guide
Page 37
7 MaxiScan Connection System
Power supply port 7-25 VDC
GND
(2 wires)
(2 wires)
1
2
6
3
7
4
8
5
9
9-pin subD male connector
Pin
MaxiScan 3100 - Installation Guide
Function
1
Power in (7 to 25 VDC 2.5 Watt unregulated)
2
Power in (7 to 25 VDC 2.5 Watt unregulated)
3
Not connected
4
Not connected
5
Not connected
6
Not connected
7
Not connected
8
Power ground
9
Power ground
37
Page 38
7 MaxiScan Connection System
Host port (RS-232 C) RTS CTS
TX RX
GND
8
7 15
6 14
5 13
4 12
3 11
2 10
1 9
15-pin subD female connector
Pin
38
Function
1
Receive data (RS-232 C)
2
Transmit data (RS-232 C)
3
Clear to send (RS-232 C)
4
Request to send (RS-232 C)
5
Not connected
6
Not connected
7
Not connected
8
Not connected
9
Not connected
10
Reserved Current Loop
11
Reserved Current Loop
12
Reserved Current Loop
13
Signal ground (RS-232 C)
14
Reserved Current Loop
15
Reserved Current Loop
MaxiScan 3100 - Installation Guide
Page 39
7 MaxiScan Connection System
Host port (current loop) RX- RX+
TX- TX+ GND
Current loop - connect pins 1 and 10
8 1
2 9
3 10
11
4
5
6
7
12
13
14
15
8
7 15
Host cable connector 15-pin subD male
6 14
5 13
4 12
11
2 10
1 9
MCS 15-pin subD female connector
Pin
MaxiScan 3100 - Installation Guide
3
Function
1
Reserved
2
Reserved RS-232 C
3
Reserved RS-232 C
4
Reserved RS-232 C
5
Not connected
6
Not connected
7
Not connected
8
Not connected
9
Not connected
10
Reserved
11
TX+ (Current Loop)
12
TX- (Current Loop)
13
Signal ground (Current Loop)
14
RX+ (Current Loop)
15
RX- (Current Loop)
39
Page 40
7 MaxiScan Connection System
Synchros port In all cases, the synchronization current provided by the external input/output device must be limited to 20 mA maximum (15 mA is a good average value). SI-
SI+ SO- SO+ +5V
5
4 9
3 8
GND
2 7
1 6
7-25 VDC
9-pin subD female connector
Pin
40
Function
1
+5 VDC out (65 mA max)
2
Positive synchronization output (SO+) - 20 mA max
3
Negative synchronization output (SO-) - 20 mA max
4
Positive synchronization input (SI+) - 20 mA max
5
Negative synchronization input (SI-) - 20 mA max
6
7-25 VDC 2.5 Watt
7
Not connected
8
Not connected
9
Power ground
MaxiScan 3100 - Installation Guide