Page 35

7 MaxiScan Connexion System (option) MCS connection box The MaxiScan Connexion System (MCS) can be used to connect the Maxiscan 3100 to a host computer, power supply and synchronization device. The MCS box is an option (P/N 0-531029-06).

SCANNER

POWER SUPPLY

MAXISCAN CONNEXION SYSTEM

MCS Port

Type

Connect to

Remarks

S can n er

15-pin subD male

MaxiScan 3100

Pow er supply

9-pin subD male

External power supply

7-25 V 2.5 Watt full-wave rectified unregulated power

H o st

15-pin subD female

Host computer

· RS-232 C (standard configuration) · Current Loop (requires MCS) Each host system interface is software programmable and requires a different cable

Synchros

9-pin subD female

I/O synchronization device

Input synchronization - reading can be triggered by an external cell, automatic machine, electrical control device Outp ut s ync hro ni za ti o n - a n e xte rna l d e vi ce (swi tch, a la rm, i nd i ca to r li g ht) c a n b e tr i g g e r e d b y a g o o d r e a d o r unsuccessful read as required

MaxiScan 3100 - Installation Guide

35

Page 36

7 MaxiScan Connection System

Scanner port RX TX CTS RTS SI+

SI- SO+ SO-

1

6

2

3

4

5

7

8

15-pin subD male connector

9

10

11

12

13

14

15

CHASSIS GND 7-25 VDC PWR GND

Pin

36

7-25 VDC

Function

1

Receive data (RS-232 C)

2

Transmit data (RS-232 C)

3

Clear to send (RS-232 C)

4

Request to send (RS-232 C)

5

Positive synchronization input (SI+)

6

Negative synchronization input (SI-)

7

Positive synchronization output (SO+)

8

Negative synchronization output (SO-)

9

Not connected

10

Power in (7 to 25 VDC 2.5 Watt unregulated)

11

Power ground

12

Shield

13

Power ground

14

Power in (7 to 25 VDC 2.5 Watt unregulated)

15

Not connected

MaxiScan 3100 - Installation Guide

Page 37

7 MaxiScan Connection System

Power supply port 7-25 VDC

GND

(2 wires)

(2 wires)

1

2

6

3

7

4

8

5

9

9-pin subD male connector

Pin

MaxiScan 3100 - Installation Guide

Function

1

Power in (7 to 25 VDC 2.5 Watt unregulated)

2

Power in (7 to 25 VDC 2.5 Watt unregulated)

3

Not connected

4

Not connected

5

Not connected

6

Not connected

7

Not connected

8

Power ground

9

Power ground

37

Page 38

7 MaxiScan Connection System

Host port (RS-232 C) RTS CTS

TX RX

GND

8

7 15

6 14

5 13

4 12

3 11

2 10

1 9

15-pin subD female connector

Pin

38

Function

1

Receive data (RS-232 C)

2

Transmit data (RS-232 C)

3

Clear to send (RS-232 C)

4

Request to send (RS-232 C)

5

Not connected

6

Not connected

7

Not connected

8

Not connected

9

Not connected

10

Reserved Current Loop

11

Reserved Current Loop

12

Reserved Current Loop

13

Signal ground (RS-232 C)

14

Reserved Current Loop

15

Reserved Current Loop

MaxiScan 3100 - Installation Guide

Page 39

7 MaxiScan Connection System

Host port (current loop) RX- RX+

TX- TX+ GND

Current loop - connect pins 1 and 10

8 1

2 9

3 10

11

4

5

6

7

12

13

14

15

8

7 15

Host cable connector 15-pin subD male

6 14

5 13

4 12

11

2 10

1 9

MCS 15-pin subD female connector

Pin

MaxiScan 3100 - Installation Guide

3

Function

1

Reserved

2

Reserved RS-232 C

3

Reserved RS-232 C

4

Reserved RS-232 C

5

Not connected

6

Not connected

7

Not connected

8

Not connected

9

Not connected

10

Reserved

11

TX+ (Current Loop)

12

TX- (Current Loop)

13

Signal ground (Current Loop)

14

RX+ (Current Loop)

15

RX- (Current Loop)

39

Page 40

7 MaxiScan Connection System

Synchros port In all cases, the synchronization current provided by the external input/output device must be limited to 20 mA maximum (15 mA is a good average value). SI-

SI+ SO- SO+ +5V

5

4 9

3 8

GND

2 7

1 6

7-25 VDC

9-pin subD female connector

Pin

40

Function

1

+5 VDC out (65 mA max)

2

Positive synchronization output (SO+) - 20 mA max

3

Negative synchronization output (SO-) - 20 mA max

4

Positive synchronization input (SI+) - 20 mA max

5

Negative synchronization input (SI-) - 20 mA max

6

7-25 VDC 2.5 Watt

7

Not connected

8

Not connected

9

Power ground

MaxiScan 3100 - Installation Guide