The text of a manual · part 13 of 26
Trakker Antares 248X Stationary Terminal User's Manual, pages 121 to 130
Pages 121 to 130 of 257
The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2486
Page 121
nugget
39 Configuring the Terminal
3
8. Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. To exit without upgrading the firmware, choose No. Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue.
] f
9. On your PC, make sure you selected the COM port and Firmware Type, and then choose OK. The PC downloads the firmware and application. Once the download is complete, the terminal boots and runs the application. Repeat these instructions to upgrade the firmware on another terminal. For help with the TRAKKER Antares firmware installation utilities, see the README.TXT instructions that ship with the utility or use the online help.
3-29
Page 122
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Recording Your Terminal’s Configuration The tables in this section list all the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER Antares 2400 Menu System. The default setting for each parameter is shown in bold italics. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup is lost. You can record the configuration on the following pages by circling the option you chose for each parameter or writing the value.
Bar Code Symbologies Table Parameter (Syntax)
Options
Location in Configuration Menu
Codabar (CD)
Disabled ABC Standard Concatenated
Symbologies Menu, Codabar option
• Start/Stop digit
Discard Retain ABCD Retain DC1-DC4
Code 11 (CG)
Disabled One check digit Two check digits
Symbologies Menu, Code 11 option
Code 16K (CP)
Disabled Standard Function code 1
Symbologies Menu, Code 16K option
Code 2 of 5 (CC)
Disabled 3 bar start/stop, label length 2 bar start/stop, label length
Symbologies Menu, 2 of 5, I2 of 5 option
Code 39 (CB)
Disabled No check digit Check digit HIBC AIAG check digit
Symbologies Menu, Code 39 option
• Check digit
Discard Retain
• ASCII
Non-full ASCII Full ASCII Mixed-full ASCII
Symbologies Menu, Code 39 option
Code 49 (CJ)
Disabled Enabled
Symbologies Menu, Code 49 option
3-30
Page 123
nugget
39 Configuring the Terminal
3
Bar Code Symbologies Table (continued) Parameter (Syntax) Code 49 (continued) • Function Code 1 (CK)
Options
Location in Configuration Menu
None (disabled) Any two ASCII characters
• Function Code 2 (CL)
\x0D\x0A (CR LF) Any four ASCII characters
• Function Code 3 (CM)
None (disabled) Any two ASCII characters
Code 93 (CF)
Disabled Enabled
Symbologies Menu, Code 93 option
Code 128 (CH)
Disabled Standard UCC/EAN-128 ISBT
Symbologies Menu, Code 128 option
• ISBT Symbology
Disabled Enabled
• ISBT Concatenated
Disabled Enabled
Interleaved 2 of 5 (CA)
Disabled Fixed length Variable length, no check digit Case Code, check digit Variable length, check digit
Symbologies Menu, 2 of 5, I2 of 5 option
MSI (CN)
Disabled No check digit 1 modulus 10 check digits 2 modulus 10 check digits
Symbologies Menu, MSI option
• Check digits
Discard Retain
Symbologies Menu, MSI option
Plessey (CI)
Disabled Discard check digit Retain check digit
Symbologies Menu, Plessey option Symbologies Menu, UPC/EAN option
UPC/EAN (CE) • UPC-A/EAN-13 (Version A)
Disabled Enabled UPC-A only
• UPC-E (Version E)
Disabled Enabled
3-31
Page 124
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Bar Code Symbologies Table (continued) Parameter (Syntax) UPC/EAN (continued) • EAN-8
Options
Location in Configuration Menu
Disabled Enabled
• Supplementals
Yes No
• Check digit
Discard Retain
• Number system digit
Discard Retain
• UPC-A leading zero
Discard Retain
RF and Ethernet Network Communications Table Note: The network parameters are different for each type of network protocol, TCP/IP or UDP Plus, loaded on the terminal. Parameter (Syntax)
Options
Location in Configuration Menu
Acknowledgement Delay Lower Limit (NV)
300 milliseconds 200 - 2000 milliseconds
Communications Menu, Advanced Network option
Acknowledgement Delay Upper Limit (NU)
5000 milliseconds 2000 - 60000 milliseconds
Communications Menu, Advanced Network option
Controller Connect Check Receive Timer (NP)
60 seconds 1 - 3600 seconds
Communications Menu, Advanced Network option
Controller Connect Check Send Timer (NQ)
35 seconds 1 - 3600 seconds
Communications Menu, Advanced Network option
Controller IP Address (NC)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
Default Router (NX)
0.0.0.0 The Router field is four numbers separated by periods.
Communications Menu, Advanced Network option
Host IP Address (NC)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
3-32
Page 125
nugget
39 Configuring the Terminal
3
RF and Ethernet Network Communications Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Maximum Retries (NR)
7 0 - 99
Communications Menu, Advanced Network option
Network Activate (NA)
Disabled 2.4 GHz RF (enabled) Ethernet
Communications Menu, Primary Network option
Network Loopback (NL)
Disabled Enabled
Communications Menu, Advanced Network option
Network Port (NG)
00023 (for TCP/IP) 05555 (for UDP Plus) 1 - 65535
Communications Menu, Advanced Network option
RF Domain (RW)
0 0 - 15
Communications Menu, Radio option
RF Inactivity Timeout (RY)
5 seconds 0 - 255 seconds
Communications Menu, Radio option
RF Roaming Flag (RR)
Allowed Not allowed
Communications Menu, Radio option
RF Security ID (RS)
None (no characters) Any 20 ASCII characters
Communications Menu, Radio option
RF Transmit Mode (RT)
BFSK QFSK Auto
Communications Menu, Radio option
RF Wakeup On Broadcast (RB)
Disabled Enabled
Communications Menu, Radio option
Subnet Mask (NS)
255.255.255.0 The Subnet Mask field is four numbers separated by periods. Each number is from 0 to 255.
Communications Menu, Advanced Network option
TCP/IP Maximum Transmit Timeout (NH)
0 (No timeout) 30 - 120 seconds 32 seconds
Communications Menu, Advanced Network option
Terminal IP Address (ND)
0.0.0.0 The IP address field is four numbers separated by periods.
Communications Menu, Primary Network option
3-33
Page 126
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Serial Network Communications Table Parameter (Syntax)
Options
Location in Configuration Menu
Baud Rate (YA)
1200 2400 4800 9600 19200 38400
Communications Menu, Serial Port options
Configuration Commands Via Serial Port (YT)
Disabled Enabled with TMF Enabled without TMF
Communications Menu, Serial Port options
Data Bits (YI)
7 8
Communications Menu, Serial Port options
EOM (YZ)
\x03 (ETX) Any two ASCII characters
Communications Menu, Serial Port options
Flow Control (YL)
None CTS checking XON/XOFF response XON/XOFF control XON/XOFF response & control CTS/RTS on DTE/DTE
Communications Menu, Serial Port options
Handshake (YJ)
Disabled Enabled
Communications Menu, Serial Port options
LRC (YF)
Disabled Enabled
Communications Menu, Serial Port options
Multi-Drop Address (YN)
A Any ASCII character
Communications Menu, Serial Port [COM2] options
Parity (YB)
None Even Odd
Communications Menu, Serial Port options
Poll (YR)
Disabled Enabled
Communications Menu, Serial Port options
Protocol (YU)
Configurable Polling Mode D Master Polling Binary Multi-drop (COM2 only)
Communications Menu, Serial Port options
SOM (YY)
\x02 (STX) Any ASCII character
Communications Menu, Serial Port options
Stop Bits (YC)
1 2
Communications Menu, Serial Port options
3-34
Page 127
nugget
39 Configuring the Terminal
3
Serial Network Communications Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Timeout Delay (YE)
5 milliseconds 100 milliseconds 500 milliseconds 2 seconds 10 seconds 20 seconds 40 seconds 60 seconds
Communications Menu, Serial Port options
Parameter (Syntax)
Options
Location in Configuration Menu
Append Time (DE)
Disabled Enabled
Terminal Menu, Append Time option
Automatic Shutoff (EZ)
0 (disabled) 2 - 75 minutes
Terminal Menu, Power Management option
Beep Volume (BV)
Off Quiet Normal Loud Very loud
Terminal Menu, Beeper option
Decode Security (CS)
Low Moderate High
Terminal Menu, Scanner option
Display Contrast (DJ)
0-7 3
Terminal Menu, Display option
Display Font Type (DT)
8x8 (T2481 and T2486 only) 8x16 16x16
Terminal Menu, Display option
Display Row Spacing (DL)
0-8 0 (T2481 and T2486) 7 (T2480 and T2485)
Terminal Menu, Display option
Display Video Mode (DN)
Original Normal Inverse
Terminal Menu, Display option
Keypad Caps Lock (KA)
On Off
Terminal Menu, Keypad option
Keypad Clicker (KC)
Disabled Enabled
Terminal Menu, Keypad option
Terminal Operations Table
3-35
Page 128
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Terminal Operations Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Keypad Table (KT)
Hardware default English QWERTY IBM 5250 IBM 3270 ANSI/VT Function numeric French AZERTY Italian QWERTY Spanish QWERTY German QWERTZ Portuguese QWERTY
Terminal Menu, Keypad option
Postamble (AE)
None (no characters) Any 25 ASCII characters
Terminal Menu, Preamble/Postamble option
Preamble (AD)
None (no characters) Any 25 ASCII characters
Terminal Menu, Preamble/Postamble option
RAM Drive Size (FR)
0 (disabled) 16 - 256K
Terminal Menu, RAM Drive option
Reader Commands (DC)
Disable all reader commands Enable all reader commands Enable override Disable override
Terminal Menu, Reader Commands option
• Enable/Disable specific Reader Commands
Abort Program Backlight Backspace Change Configuration Clear Default Configuration Delete File Enter Accumulate mode Exit Accumulate mode List Files Multiple-Read Labels Receive File Rename File Reset Run Program Scanner Trigger Off Scanner Trigger On Test & Service mode Transmit File
Terminal Menu, Reader Commands option, Enable single commands option
Resume Execution (ER)
Not Allowed Allowed
Terminal Menu, Power Management option
3-36
Page 129
nugget
39 Configuring the Terminal
3
Terminal Operations Table (continued) Parameter (Syntax)
Options
Location in Configuration Menu
Scan Ahead (SD)
Disabled Enabled
Terminal Menu, Scanner option
Scanner Mode (SB)
One-Shot mode Automatic mode
Terminal Menu, Scanner option
Scanner Redundancy (SR)
None Normal High
Terminal Menu, Scanner option
Scanner Selection (SS)
All compatible scanners 146X CCD scanners 151X laser scanners 1545 laser scanner Symbol scanners 155X laser scanners
Terminal Menu, Scanner option
Scanner Timeout (SA)
Disabled (0) 1 - 60 seconds
Terminal Menu, Scanner option
Scanner Trigger (SC)
Level Edge
Terminal Menu, Scanner option
Time in Seconds (DA)
Disabled Enabled
Terminal Menu, Append Time option
3-37