Page 111
nugget
39 Configuring the Terminal
3
Saving Configuration Changes in Flash Memory The TRAKKER Antares terminals use two copies of the configuration: Runtime or RAM configuration This configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration This configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the four ways you can configure the terminal and how the configuration is updated: Runtime or RAM Configuration Updated?
Boot or Flash Configuration Updated?
Using the TRAKKER Antares 2400 Menu System
Yes (see Note)
Yes (see Note)
Scanning bar code labels
Yes
No
From a host application through the serial port
Yes
No
T248X from the network (Model 200 Controller or host)
Yes
No
Configure the Terminal
Note: You are prompted to save your changes in RAM and flash as you exit the Configuration Menu and the TRAKKER Antares 2400 Menu System. Your changes are saved if you choose Yes at each screen. If you configure the terminal by scanning bar code labels, through the serial port or from the network, you may want to save the changes in flash memory using one of these methods: •
Scan or send the Save Configuration in Flash Memory reader command.
•
Use the TRAKKER Antares 2400 Menu System.
To save configuration changes using the reader command •
Scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
Or, send the command .+1 as the last command from the controller or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”
3-19
Page 112
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To save configuration changes using the menu system 1. Press or scan this bar code.
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 2. Choose System Menu and press
The System Menu appears.
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051
3. Choose the Store Configuration command and press Configuration screen appears.
The Store
STORE CONFIGURATION Store Configuration in Flash Memory
OK
CANCEL 248XU.072
4. Choose OK to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears.
] to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ] to exit the 5. Press
TRAKKER Antares 2400 Menu System.
3-20
Page 113
nugget
39 Configuring the Terminal
3
Restoring the Terminal’s Default Configuration When you configure the terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can use the TRAKKER Antares 2400 Menu System or scan the Default Configuration bar code label to return the terminal to its default configuration. Note: If you restore the default configuration, you need to set the primary network communications parameters on the T2485 and T2486 to reestablish communications with other devices in the 2.4 GHz RF network. You may also need to reset the serial port or Ethernet parameters to communicate with other devices in your wired network. To restore the default configuration using the reader command •
Scan this bar code label: Default Configuration
*.+0* *.+0*
To restore the default configuration using the menu system 1. Press or scan this bar code:
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears.
The System Menu appears. 3. Choose the Load Default Values command and press The Load Default 2. Choose System Menu and press Values screen appears.
3-21
Page 114
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Load Default Values Screen LOAD
DEFAULT
VALUES
Load default configuration values in RAM? (Overwrites current configuration)
OK
CANCEL 248XU.056
4. Choose OK and press to load the default configuration values. The default values will override the current runtime configuration on the terminal. To exit without loading the default values, choose Cancel and press The System Menu appears.
] to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ] to exit the 5. Press
TRAKKER Antares 2400 Menu System. For help exiting the menu system, see “Exiting the TRAKKER Antares 2400 Menu System” earlier in this chapter.
Configuring Drives and Memory on the Terminal The TRAKKER Antares 248X terminals come with a 750K flash drive (C) and 512K RAM reserved for applications. You can also order a T248X with an additional 2MB extended flash memory option. You can customize the terminal to your needs by configuring • up to 256K of the 512K RAM as a RAM drive.
• the additional 2MB flash memory to either store double-byte fonts or as a 2MB drive.
The next sections explain how to customize the terminal by configuring RAM and configuring flash memory.
3-22
Page 115
nugget
39 Configuring the Terminal
3
Configuring the RAM Drive On the T248X, you have 512K total RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. For example, if your application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. By default, the RAM drive is not configured and the memory is available for applications. You can configure the size of the RAM drive (E) and use drive E to temporarily store data and files (up to 32 files). Important: After you disable or configure the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed. To configure the RAM drive
1. Press or scan this bar code to access the TRAKKER Antares 2400 Menu System: Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears.
248XU.001
3-23
Page 116
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Y
2. Press to choose the Configuration Menu and then press Configuration Menu appears. CONFIGURATION
The
MENU
Symbologies Menu Communications Menu Terminal Menu
⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.010
Y
3. Press to choose the Terminal Menu and then press Menu appears.
The Terminal
TERMINAL MENU Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.037
Y
4. Press to choose the RAM Drive command and then press Drive screen appears.
The RAM
5. In the Size field, type the RAM drive size. Enter a value from 16 to 256 to configure RAM as drive E. If you do not want the terminal to create a RAM drive, enter a value of zero (0).
to save the changes and exit the RAM Drive screen. 7. Press ] to exit the Terminal Menu. The Configuration Menu appears. 8. Press ] to exit the Configuration Menu. 9. Press to choose Yes and save the new configuration in RAM. 10. Press ] to exit the TRAKKER Antares 2400 Menu System. 11. Press to choose Yes and store your changes permanently in flash 6. Press memory. The RAM drive change must be saved in flash memory for the change to take effect.
3-24
Page 117
nugget
12. Press
39 Configuring the Terminal
3 to choose OK and exit the TRAKKER Antares 2400 Menu System.
13. Scan this bar code to reset the terminal: Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see Chapter 6, “Reader Command Reference.” Or, if the Resume Execution command is configured to resume “not allowed,” turn the terminal off and then back on to reset the terminal. Use the TRAKKER Antares 2400 Menu System to configure the Resume Execution command. Choose Terminal Menu from the Configuration Menu and then choose Power Management.
Configuring Flash Memory If you have a T248X with the optional 2MB extended flash memory, you can use the flash memory either to store double-byte fonts or as a 2MB drive. By default, the 2MB flash memory is configured to store a double-byte font set (up to 2MB maximum). If you are not using double-byte fonts, you can configure the 2MB flash memory as a storage drive (D). If you configure the flash memory as drive D, use this drive to store large lookup tables and data files (up to 32 files). Note: You can only configure the 2MB flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory. To configure flash memory to store double-byte fonts 1. Scan this bar code: Configure Flash Memory for Double-Byte Fonts
*$+FF0* *$+FF0*
2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
3-25
Page 118
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 3. Scan this bar code to boot the terminal and use the 2MB flash memory to store double-byte fonts: Reset Firmware
*-.* *-.*
Note: When you boot or reset the terminal, all files on drive D are destroyed. Flash memory is now configured to store double-byte fonts. 4. Use the TRAKKER Antares Font Editor to download the double-byte font set to the terminal. See your local Intermec sales representative or visit the Intermec web site (www.intermec.com) for information about the TRAKKER Antares Font Editor. To configure flash memory as drive D 1. Scan this bar code: Configure Flash Memory as Drive D
*$+FF32* *$+FF32*
Note: A value of 32 configures drive D as a 2MB drive. 2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
3. Scan this bar code to boot the terminal and use flash memory as drive D: Reset Firmware
*-.* *-.*
Note: When you boot or reset the terminal, any fonts in flash memory are erased. Flash memory is now configured as drive D.
3-26
Page 119
nugget
39 Configuring the Terminal
3
Upgrading the Firmware The terminal firmware includes these items: •
TRAKKER Antares 2400 Menu System
•
Terminal emulation, screen mapping, or sample application
•
TE Configuration Menu (3270, 5250, VT/ANSI terminals only)
•
Operating environment, firmware, and drivers
When a new release of the firmware is available, you can order a firmware upgrade kit. There is a kit for TCP/IP terminals and a separate kit for UDP Plus terminals. To order the TRAKKER Antares Firmware Upgrade Kit, contact your local Intermec service representative. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the T248X from a host computer or PC using serial communications. For help connecting the terminal, see Chapter 2, “Installing the Terminal.” Once the terminal is connected, you can upgrade the firmware. Note: You can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the Model 200 Controller with v3.0 software and higher. For help, see the Model 200 Controller System Manual. To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. The Firmware Installation utility includes detailed online help. You click the Help button anytime to get more information. 3. Choose the COM port and the Firmware Type (application). For example, the TRAKKER Antares 2480 sample application is one firmware type. 4. On the TRAKKER Antares terminal, press code label:
or scan this bar
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears.
3-27
Page 120
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 5. Choose System Menu and press
The System Menu appears.
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051
6. Choose Upgrade Firmware and press appears.
The Upgrade Firmware screen
UPGRADE FIRMWARE Upgrade terminal firmware? Make sure the terminal is connected to a host computer.
OK
CANCEL 248XU.074
7. Choose OK to continue. The next screen appears. Are you want to sure you continue?
Selecting YES will upgrade and replace all of the terminal's firmware. Selecting NO will exit without upgrading firmware.
YES
NO 242XU.152
3-28