Page 81

nugget

39 Installing the Terminal

2

To configure the T2485 or T2486 to use RF communications 1. Configure the Model 200 Controller (UDP Plus) or host (TCP/IP). For help with the controller, see the Model 200 Controller System Manual (Part No. 063439). 2. Configure the access point. For help, see your access point user’s manual.

_ Y

3. Configure the terminal. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.

Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.

CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu

⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.217

Y The 5. Press to choose the Primary Network command. The Primary Network

4. Press to choose the Communications Menu and then press Communications Menu appears. screen appears.

UDP Plus Primary Network

TCP/IP Primary Network

PRIMARY NETWORK

PRIMARY NETWORK

Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0

Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0

OK

CANCEL

OK

CANCEL 248XU.186

2-39

Page 82

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

`

6. Press to set the Network Activate command to 2.4 GHz RF. Press move to the next field.

Y to

Enter the Controller IP address for a UDP Plus network. Enter the Host IP address for a TCP/IP network. Enter the Terminal IP address. IP address fields consist of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .

Y

For example, if your terminal IP address is 192.100.100.3, type:

Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

to save the changes and exit the Primary Network screen. 8. Press Y to choose the Radio command and then press The Radio 7. Press screen appears.

UDP Plus and TCP/IP Radio RADIO Domain: 00 Security ID: (ID unchanged) Wakeup on Broadcast: No Roam Flag: Allowed Transmit Mode: BFSK Inactivity Timeout: 5 sec OK

CANCEL 248XU.013

9. In the Domain field, type a number from 0 to 15 and then press domain must match the number set on the access point.

Y . The

In the Security ID field, type the RF security identification and then press . The Security ID is case-sensitive and can be up to 20 characters long. It must match the security ID set on the access point.

Y

Press to save the changes and exit the Radio screen.

Note: If the terminal is on a different IP subnetwork from the Model 200 Controller or host, you must also configure the default router and subnet mask. Choose the Advanced Network command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.”

2-40

Page 83

nugget

39 Installing the Terminal

2

_

10. For TCP/IP networks, press to choose the Advanced Network command and then press . The Advanced Network screen appears.

UDP Plus Advanced Network ADVANCED NETWORK Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07

TCP/IP Advanced Network ADVANCED NETWORK Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 032 sec

OK

CANCEL

` more 248XU.192

Note: For UDP Plus networks, the Network Port default is 5555, which matches the default value set on the Model 200 Controller. 11. In the Network Port field, type a number from 1 to 65535 and then press . The default value is 23, which enables VT/ANSI Telnet communications. If you are not using Telnet communications, enter the port number used by your application.

] 13. Press ] to exit the Configuration Menu. 14. Press to choose Yes and save the new configuration in RAM. Once the changes are saved, the terminal uses the new configuration. 15. Press ] to exit the TRAKKER Antares 2400 Menu System. 16. Press to choose Yes and store your changes permanently in flash memory. 17. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. 12. Press to exit the Communications Menu. The Configuration Menu appears.

The T2485 or T2486 will now try to establish communications with the Model 200 Controller or the host.

For terminal emulation applications in a UDP Plus network, you need to configure the host name in the TE Configuration menu to establish communications. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. Once the terminal connects, the login or initial screen for your application appears and the Connect status light remains on. You can begin using the terminal to collect data. Follow the instructions in the next section, “Starting the Application and Using the Terminal.”

2-41

Page 84

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Note: While the terminal is connecting to the controller or host, the terminal ignores any input from the keypad or scanner. Wait until the terminal is connected before you try to enter any data.

Starting the Application and Using the Terminal Your T248X ships loaded with one of these applications: •

Sample application

•

Terminal emulation application (IBM 3270, IBM 5250, or VT/ANSI)

•

Screen mapping application.

To start the application and use the terminal f

1. Press to turn on the terminal. The login or initial screen for your application appears. 2. Check the four application screens shown next in the left column. Find the application screen that matches the one on your terminal. Follow the instructions on the right of the screen to use the T248X. Sample Application Screen

1998/01/08

08:10:50

248XU.151 a. Use the sample application to scan bar code labels and test the T248X keypad. b. Connect the T248X to a host computer using one of the COM ports or the Ethernet connector. For help, see “Installing the Terminal and Connecting External Devices” earlier in this chapter. c. Download your data collection application to the T248X and run it. For help, see Chapter 5, “Using Custom Applications and Screen Mapping.”

3270/5250 TE Sign-On Screen

Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...

248XU.087

2-42 a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide. b. Log in to a terminal emulation session. c. Start using the T248X to collect and transmit data.

Page 85

nugget

39 Installing the Terminal

2

Step 2: Using the Application (continued) VT/ANSI TE Login Screen a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide.

<login:

b. Log in to a terminal emulation session. c. Start using the T248X to collect and transmit data. 248XU.088

Screen Mapping Application

File a. Download or request a template from the Model 200 Controller.

Name:

b. Download or request a validation file from the controller. c. Start using the T248X to collect and transmit data.

248XU.089

2-43

Page 86

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Turning the Terminal On and Off The terminal’s Suspend/Resume key is the as shown in this illustration.

f key on the left side of the keypad,

Suspend/Resume key esc

Q tab

W

S

A

Caps

I/O

Z

"

248XU.038 f

When you press to turn off the terminal, the terminal does not actually shut off, but goes into a Suspend mode. This mode is referred to as “off” in the rest of this manual. In Suspend mode, the terminal continues to power all memory and turns off the power to most of the hardware.

f

When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off, or the terminal boots and restarts your application. Resume is controlled through a parameter or command called Resume Execution. By default, the terminal resumes your application. You can configure the terminal to disable the disabled, you cannot turn off the terminal. To enable or disable the • f key. When the f key is f key

Scan one of these bar code labels: Enable the f

Key

*$+EF0* *$+EF0*

Disable the f

Key

*$+EF1* *$+EF1*

By default, the

2-44 f key is enabled so you can turn the terminal on and off.

Page 87

nugget

39 Installing the Terminal

2

Using the Badge Scanner and Other Input Devices You use the badge scanner and other bar code input devices that are connected to the TRAKKER Antares 248X terminals to scan and enter bar code data. The terminal decodes the bar code label and enters the data or command you scanned. The T248X has two bar code input ports: •

Badge scanner (6-pin) connector

•

External scanner (Stewart 10-pin) connector

Note: Although you can have two bar code input devices connected to the terminal at the same time, the terminal can only process data from one input device at a time. When you unpack the terminal and begin using it, only three bar code symbologies are enabled: Code 39, Code 128, and UPC/EAN. If you are using bar code labels that are encoded in another symbology, you need to enable that symbology on the terminal. For help, see “Scanning Bar Codes to Enable Symbologies” in Chapter 3. The next sections cover these topics: •

Using the Badge Scanner

•

Using a Wand, Laser Scanner, or CCD Scanner

•

Scanning Options

For help connecting an input device, see “Connecting Power and Input Devices” earlier in this chapter, or see your badge scanner accessory instruction sheet.

Using the Badge Scanner You can order the T248X with an infrared or visible light badge scanner. You can also order the badge scanner as an accessory and attach the scanner to your terminal. The badge scanner is always on and ready to read bar code data. To use the badge scanner 1. Press f to turn on the terminal.

2. Hold the bar-coded object such as an identification badge with the bar code facing toward the terminal. 3. Slide the bar-coded object through the badge scanner slot in either direction. Once the bar code is scanned successfully, the Good Read status light turns on for 2 seconds.

2-45

Page 88

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Using the Badge Scanner

XYZ *

*Ja JAC ck* K*

COR

P.

248XU.021

The scanning beam in the badge scanner must pass through the entire bar code. The beam path is 0.5 in (1.27 cm) from the bottom of the scanning slot. The bar code label must be • at least 0.2 in (0.51 cm) tall with a center line 0.5 in (1.27 cm) from the edge.

• parallel to the edge of the card or object that passes through the scanner.

Note: You can also attach an input device to the 6-pin connector instead of the badge scanner.

Using a Wand, Laser Scanner, or CCD Scanner You can attach a wand, laser scanner, or CCD scanner to the external scanner connector on the terminal. Since the external scanner port is a Stewart 10-pin connector, you must use an interface cable to connect an input device. You can use these input devices with the terminal:

2-46

•

Intermec 1354 and 1355 badge scanners

•

Intermec 1463A and 1463D CCD scanners

•

Intermec 1516A, 1517A, 1517B, 1518, and 1519A laser scanners

•

Intermec 1545 laser scanner

•

Intermec 1550A laser scanner

•

Intermec 126X, 127X, and 128X wands

Page 89

nugget

39 Installing the Terminal

2

Note: If you do not have a device installed on the badge scanner connector, you can use the Intermec 1464 CCD scanner, the Intermec 1550B laser scanner, and the Intermec 1551 laser scanner. To use the 1463A and 1463D CCD scanners together with a device installed on the badge scanner connector, you must configure the 1463A or 1463D Trigger mode to either Manual Trigger or Auto-Trigger.

Using a Wand, Laser Scanner, or CCD Scanner

248XU.020

Once you have the input device attached, you can use the scanning options that are described in the next section to customize bar code input. You may also need to configure the Scanner Selection command to identify the type of input device. The terminal can optimize the scanning performance by using the scanner you define in the Scanner Selection command. To use the input device 1. Press f to turn on the terminal.

2. Scan the bar code. Once the bar code is scanned successfully, the Good Read status light turns on for 2 seconds. For help on scanning with your input device, see the instruction sheet for the input device.

2-47

Page 90

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Scanning Options You can set several configuration command parameters to configure the external scanner (Stewart 10-pin) to meet your needs. There are several ways to set the scanner commands on the terminal. For help, see Chapter 3, “Configuring the Terminal.” The parameters available are: Decode Security Defines the security level to use when decoding bar codes. When you select a lower decode security level, the terminal can decode bar codes with poorer print quality. Scan Ahead Allows you to scan a number of bar code labels at one time. The labels are held in a stack until the terminal can process the data. Scanner Mode Defines how the scanner operates when you activate a laser scanner that is connected to the scanner port. In One-Shot mode, the laser turns on and stays on until you release the scanner trigger, or a label is decoded. In Automatic mode, you can continuously scan bar code labels without having to release the scanner trigger between labels. Scanner Redundancy Defines the number of scans (voting) the scanner takes of the same label. When set, voting requires the terminal to decode the same bar code label multiple times during a single scanner event, and compare the decoded information for a match before signaling a good read. Scanner Selection Identifies the type of scanner you have connected to the scanner port on the TRAKKER Antares terminal. The terminal can optimize the scanning performance by using the scanner you define in this command. Scanner Timeout Defines the maximum length of time the scanner stays on each time you activate a laser scanner that is connected to the scanner port. Scanner Trigger Allows you to set the triggering to level or edge triggering. With level triggering, you activate the scanner and the laser turns on and stays on until you release the trigger on a scanner that is connected to the scanner port. In edge triggering, you activate the scanner and the laser turns on and stays on until you activate the scanner a second time, or the scanner timeout turns it off.

2-48