Page 91

3 Configuring the Terminal

Page 92

This page is a scan with no text; see it in the PDF.

Page 93

nugget

39 Configuring the Terminal

3

This chapter explains how to configure the terminal, discusses the terminal’s configuration parameters, and tells you how to restore the default configuration. The table at the end of the chapter lists all the configuration parameters and their options.

How to Configure the Terminal You can configure the TRAKKER Antares 248X terminals by using either of the methods described in detail in this chapter: Using the TRAKKER Antares 2400 Menu System With menus and screens, the TRAKKER Antares 2400 Menu System lets you view the current configuration and modify configuration parameters. Configuring the terminal by scanning bar codes You can change the terminal’s current configuration by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This method is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual, or you can create your own bar code labels. Note: You can also configure the terminal from a remote device. You can configure the T2480/1 with the Ethernet option or T2485/6 from the Model 200 Controller or from an application on the host. You can configure any T248X by sending commands from an application through the serial port. For help, see Chapter 4, “Operating the Terminal in a Network.”

Learning About Configuration Parameters You can customize many operating characteristics of the TRAKKER Antares 248X terminals, such as the volume of its audio signals and the bar code symbologies it decodes. These characteristics are controlled by configuration parameters. The values you set for the configuration parameters determine how the terminal operates. By customizing the terminal’s configuration, you can set up the terminal to operate easily and efficiently within your data collection system. The configuration parameters can be organized into three groups, which are discussed in the next sections: bar code symbologies, communications, and general operation. When you configure the terminal, you are performing one or more of these tasks: •

Choosing the Symbologies the Terminal Decodes

•

Specifying How the Terminal Will Communicate

•

Controlling How the Terminal Will Operate

3-3

Page 94

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Choosing the Symbologies the Terminal Decodes This list contains all the bar code symbologies the terminal can decode: •

Codabar

•

Code 49

•

Code 11

•

Code 93

•

Code 128

•

Interleaved 2 of 5 (I 2 of 5)

•

Code 16K

•

MSI

•

Code 2 of 5

•

Plessey

•

Code 39

•

UPC/EAN

When the terminal ships, only these three symbologies are enabled: •

Code 39

•

Code 128

•

UPC/EAN

If you are using one of the other symbologies to encode your bar code labels, you need to configure the terminal and enable the symbology. To quickly enable symbologies, see “Scanning Bar Codes to Enable Symbologies” later in this chapter. To ensure that the terminal can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. When you enable each bar code symbology, you may need to set a check digit, the length of the bar code label, or other options.

Specifying How the Terminal Will Communicate The T2480 and T2481 use serial communications to send data to and from another serial device. With the Ethernet option, the T2480 and T2481 can communicate to a host or device on an Ethernet network. The T2485 and T2486 use radio frequency (RF) communications to communicate with other devices in Intermec’s 2.4 GHz RF network. You can also use the serial port(s) on the T2485 or T2486 to send and receive data. Before you can use the T248X in your wired or RF network, you must configure the serial port, Ethernet, or RF network parameters. On the T2485 and T2486, you must set the RF network parameters, radio parameters, and address information before the terminal can communicate with other devices in your 2.4 GHz RF network. For example, you must set the Terminal IP Address so the T2485 or T2486 can communicate with other network devices. To learn how to configure the terminal to fit into your wired, Ethernet, or 2.4 GHz RF network, see Chapter 4, “Operating the Terminal in a Network.”

3-4

Page 95

nugget

39 Configuring the Terminal

3

Controlling How the Terminal Will Operate The operating parameters let you adjust the way the terminal operates. By customizing the operating parameters, you can • set the terminal to automatically shut off after a specified length of time.

• set the terminal to resume applications or restart applications.

• modify data transactions by appending the time.

• modify bar code data by using a preamble and postamble.

• enable or disable specific reader commands.

• configure a RAM drive.

• change the volume of the audio signals (beeper and keypad clicker).

• control the display contrast, font size, row spacing, and video mode.

• enable or disable the keypad clicker and keypad caps lock.

• customize the way the scan module operates by selecting scan ahead data buffering, type of scanner device, decode security level, scanner timeout value, and trigger modes.

3-5

Page 96

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Configuring the Terminal With the Menu System The TRAKKER Antares 2400 Menu System is a menu-driven application that lets you configure the terminal, manage files, view system information, and run diagnostics. You can access the TRAKKER Antares 2400 Menu System while running any application. To access the TRAKKER Antares 2400 Menu System •

Press or scan this bar code:

Enter Test and Service Mode

*..-.* *..-.*

Note: You can also press 2400 Menu System.

3 , to access the TRAKKER Antares

The Main Menu appears, displaying four menu options. Configuration Menu Choose the Configuration Menu to configure bar code symbologies, network and communications parameters, serial port parameters, and the terminal’s operating characteristics. Diagnostics Menu Choose the Diagnostics Menu to run hardware, software, or system diagnostics to help analyze and fix problems on the terminal. You can also view information about the backup battery and the system.

248XU.001

System Menu Choose the System Menu to manage files, load the default configuration, set the time and date, store the terminal’s configuration in flash memory, and upgrade the firmware. About TRAKKER 2400 Choose this option to see the part number, firmware version, and RF protocol (UDP Plus or TCP/IP) loaded on the terminal. You may need this information if you are working a problem with an Intermec representative.

3-6

Page 97

nugget

3

39 Configuring the Terminal

The TRAKKER Antares 2400 Menu System at a Glance MAIN

MENU

CONFIGURATION Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400

MENU

Symbologies Menu Communications Menu Terminal Menu

SYMBOLOGIES

SYSTEM

MENU

*Code 39 Codabar Code 11 Code 49 Code 93 *Code 128 Code 16K 2of5 / I 2of5 MSI Plessey *UPC / EAN

MENU

File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄

CONFIGURATION

MENU

Symbologies Menu Communications Menu Terminal Menu DIAGNOSTICS

MENU

COMMUNICATIONS

Software Diagnosticss Hardware Diagnostics System Diagnostics

Serial Serial Serial

T2480/1 Without Ethernet

⁄

Port Port Port

MENU

[COM1] [COM2] [COM4]

⁄ SOFTWARE

DIAGNOSTICS

COMMUNICATIONS

Error Logger Application Events Task Status Clear Task Profiles

T2480/1 ⁄

With Ethernet HARDWARE

MENU

Primary Network Advanced Network Serial Port [COM1] Serial Port [COM2] Serial Port [COM4]

DIAGNOSTICS

Hardware Config Battery/PIC Status Display Test Keypad Test Main Board Menu Radio Test Scanner Test

COMMUNICATIONS

T2485/6

MENU

Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM2] Serial Port [COM4]

⁄ SYSTEM

DIAGNOSTICS

Subsystem Versions Access Point App Efficiency Serial Port Test Malloc Info Menu

CONFIGURATION

MENU

⁄

Symbologies Menu Communications Menu Terminal Menu

TERMINAL MENU Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner

248XU.178

3-7

Page 98

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Exploring the Configuration and System Menus When you access the TRAKKER Antares 2400 Menu System, the Main Menu appears. You use the Configuration Menu and the System Menu to configure the terminal. The Configuration Menu contains these commands: CONFIGURATION

MENU

Symbologies Menu Communications Menu Terminal Menu

⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.010

Symbologies Menu Choose the Symbologies Menu to configure and activate the bar code symbologies the terminal can decode. An asterisk (*) on the Symbologies Menu indicates that the symbology is active. For help, see “Choosing the Symbologies the Terminal Decodes” earlier in this chapter. Communications Menu Choose the Communications Menu to configure the primary network parameters, the advanced network parameters, the radio parameters, or the serial port parameters. The options you see on the Communications Menu depend on the type of terminal and the features installed in the terminal. For example, the Radio menu is not needed on a T2480 or T2481. For help, see Chapter 4, “Operating the Terminal in a Network.” Terminal Menu Choose the Terminal Menu to configure the way the terminal, keypad, scanner, or screen operate. For help, see “Controlling How the Terminal Will Operate” earlier in this chapter. The System Menu contains these commands: File Manager Lets you manage the files on each drive. You can run an application from drive C, delete a file from any drive, or rename a file on any drive. For help using the File Manager, see “Running the Application on the Terminal” in Chapter 5.

SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051

3-8

Page 99

nugget

39 Configuring the Terminal

3

Load Default Values Lets you load the default configuration values. For help, see “Restoring the Terminal’s Default Configuration” later in this chapter. Set Time and Date Lets you set the current time and date. For help, see “Setting the Time and Date” in Chapter 2. Store Configuration Stores the current configuration in flash memory, including any changes you have made in the menu system. When you exit the TRAKKER Antares 2400 Menu System, you will also be prompted to save your changes. For help, see “Exiting the TRAKKER Antares 2400 Menu System” later in this chapter. Upgrade Firmware Lets you upgrade the system firmware on the terminal. For help, see “Upgrading the Firmware” later in this chapter. You can use the keystrokes described next to move around in the TRAKKER Antares 2400 Menu System, or you can scan bar code labels. For a list of bar code labels, see the “Full ASCII Bar Code Chart” in Appendix B.

Selecting Menus and Commands

_ Y

Press or to choose a menu name from the Main Menu. Then press display the commands in the selected menu. In this example, you press to display the System Menu: MAIN

MENU

SYSTEM to

MENU

Configuration Menu Diagnostics Menu System Menu About TRAKKER 2400

File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware

_` Select item [Enter] Next screen [F1] Help [Esc] Exit

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.058

Press _ or Y to choose a command or option from a menu, and then press execute the command or option. Note: You can press b at any time to display a help screen. Press ] to exit a help screen.

3-9

Page 100

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Filling In Fields and Marking Check Boxes Screens list the options for each configuration parameter, diagnostic, or system option. Below each option name is either a toggle field or an entry field:

g , ` , or to view the options for that field. • In an entry field, you type a value into the field. To edit the data in an entry field, use the g , ` , , or keys. You can also use the Delete ( ) and Insert ( ) keys to edit an entry field. For example, the Code 49/Code 16K screen has toggle and entry fields. The Code 49 field is a toggle field. Press to toggle between Enabled and

•

In a toggle field, you press

Disabled. The Function Codes fields for F1, F2, and F3 are entry fields. You type a value into the field for each function code. CODE Code

49 49:

/

CODE

16K

Enabled

Code 49 Function Codes: F1: F2: \x0D\x0A F3: Code 16K: Standard OK

CANCEL 248XU.052

Some screens contain check boxes. Check boxes are used when more than one option can be selected at one time. To mark or clear check boxes •

Press . For example, to disable the Backspace reader command, choose the Backspace check box and press to clear the check box.

READER COMMAND MENU [Space] to enable or disable a command [X] Abort Program [X] Backlight [X] Backspace [X] Change Config [X] Clear [X] Default Config [X] Delete File [X] Enter Accum [X] Exit Accum [X] List Files

[X] [X] [X] [X] [X] [X] [X] [X] [X]

OK

Multi-Read Receive File Rename File Reset Run Program Scanner On Scanner Off Test & Service Transmit File

CANCEL more

_

248XU.053

3-10