The text of a manual · part 11 of 26
TRAKKER Antares 248X Stationary Terminal User's Manual, pages 101 to 110
Pages 101 to 110 of 255
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2480, Intermec 2481 and Intermec 2485
Page 101
nugget
39 Configuring the Terminal
3
To move to the next field •
Press
Y or a.
To move to the previous field •
Press
_.
Entering ASCII Control Characters You can include ASCII control characters in a postamble or preamble by using the TRAKKER Antares 2400 Menu System. You can configure the postamble or preamble to characters from the full or extended ASCII character sets. For example, the Field Exit code (Ü) for 5250 terminal emulation is an extended ASCII character that is often configured as the postamble. For a list of the full and extended ASCII characters, see Appendix B, “Full ASCII Charts,” or the TRAKKER Antares Terminal Emulation User’s Guide. Note: For more help on using the 5250 Field Exit code, see “Auto-Advancing Through Fields on 5250 TE Screens” in the TRAKKER Antares Terminal Emulation User’s Guide. To enter ASCII characters for a preamble or postamble 1. Decide which ASCII control character you want to set for the preamble or postamble. Look up the control character in the Full ASCII Table in Appendix B and find the two-digit hexadecimal number. For example, ETX in the Full ASCII Table is the hexadecimal value 03. To enter an extended ASCII character, look up the hexadecimal number for the character in the “TRAKKER Antares Terminal Font Set” in Appendix C. For example, 9A is the hexadecimal value for Ü, the 5250 Field Exit code. PREAMBLE / POSTAMBLE 2. Use the TRAKKER Antares 2400 Menu System to configure a preamble or postamble. From the Main Menu, choose Configuration Menu.
Preamble: abc Postamble: \x0D\x0A
3. From the Configuration Menu, choose Terminal Menu. 4. From the Terminal Menu, choose Preamble/Postamble.
OK
CANCEL 248XU.057
3-11
Page 102
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 5. Move the cursor to the field for the preamble or postamble. 6. Type the control character, extended ASCII character, or escape character sequence in the preamble or postamble field. Note: On the oversized function numeric keypad, you can scan bar code labels to enter characters in the preamble or postamble field. For help, see Appendix B, “Full ASCII Charts.” •
To type a control character or extended ASCII character in the preamble or postamble field, use this syntax: \xhh where hh is the one or two-digit hexadecimal number for the control character or extended ASCII character. For example, to enter ETX as a preamble, type: \x03
To enter Ü (5250 Field Exit code) as the postamble, type: \x9A
•
To type an escape character (backslash) in the preamble or postamble field, use the next table. The application ignores the first backslash (\) character and saves the next character(s). For example: Enter These Characters
Preamble/Postamble Saved
\\
\
\h h
\x x
\\k
\k
\ no data or choose OK to save your changes and exit the screen. 8. Choose another menu from the Terminal Menu or press ] to exit. The 7. Press
Configuration Menu appears.
For help exiting the menu system, see “Exiting the Configuration Menu” later in this chapter.
3-12
Page 103
nugget
39 Configuring the Terminal
3
Exiting Screens and Saving Changes When you exit a screen, you can save or discard your changes: Task
Description
Choose Cancel and press Or, press ] with the
To exit a screen and save the changes
Choose OK and press . Or, press with the cursor in any field except the Cancel button.
To exit a screen and discard the changes cursor in any field.
Exiting the Configuration Menu
]
1. Press to exit the Configuration Menu. If you have made any changes to the current configuration, this screen prompts you to save the new configuration in RAM. The current configuration (also called the runtime configuration) is the set of parameters currently enabled on the terminal.
Save new configuration (in
RAM)?
Yes
No
CANCEL
248XU.059
2. Choose Yes and press to save your changes in RAM and update the current configuration on the terminal. Choose No and press to exit without changing the configuration. The Main Menu appears. 3. Choose another menu from the Main Menu or press TRAKKER Antares 2400 Menu System.
] to exit the
For help exiting the menu system, see the next procedure for “Exiting the TRAKKER Antares 2400 Menu System.”
3-13
Page 104
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Exiting the TRAKKER Antares 2400 Menu System
]
1. From the Main Menu, press . If you have made any changes, the next screen prompts you to store the changes in flash memory. You can also save the runtime configuration in flash memory by choosing the Store Configuration command from the System Menu. For help, see “Saving Configuration Changes in Flash Memory” later in this chapter. Note: When you boot or reset the terminal, it uses the configuration you last saved in flash memory.
Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
248XU.054
2. Choose Yes and press to save your changes in flash memory. Choose No and press to exit without saving. The Exiting TRAKKER Antares 2400 Menu System screen appears.
Note: If you changed the configuration, you were prompted to save your changes in RAM as you exited the Configuration Menu. If you want the configuration changes to be stored in flash memory, you need to choose Yes in this screen.
Exiting TRAKKER Antares 2400 Menu System
OK
CANCEL 248XU.055
3-14
Page 105
nugget
39 Configuring the Terminal
3
3. Choose OK and press to exit the TRAKKER Antares 2400 Menu System. Choose Cancel and press to return to the Main Menu. After you exit the menu system, the terminal will resume the application you were running when you started the menu system.
Configuring the Terminal by Scanning Bar Codes You can configure the terminal by scanning bar code labels listed in this manual or by creating your own Code 39 or Code 93 bar code labels. Note: If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. For example, you can use the Beep Volume configuration command to adjust the volume of the terminal’s audio signals. You can scan this bar code label to set the beep volume to a quiet audio level: Set Beep Volume to Quiet
*$+BV1* *$+BV1*
You can create bar code labels that contain more than one configuration command. For example, you can create one bar code label to configure the terminal for: •
One-Shot Scanner mode (SB0)
•
Scanner Redundancy set to high (SR2)
•
Beep Volume set to very loud (BV4)
•
Disable Keypad Clicker (KC0)
One-Shot Scanner Mode, Set Scanner Redundancy to High, Set Beep Volume to Very Loud, Disable Keypad Clicker
*$+SB0SR2BV4KC0* *$+SB0SR2BV4KC0*
To configure these same four configuration commands, you can scan four separate bar code labels.
3-15
Page 106
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 When you create a bar code label to set several configuration commands, follow these rules: •
The bar code label must be printed using Code 39 or Code 93 symbology.
•
The bar code label must include the start and stop character. Most bar code printing utilities automatically include the start and stop character.
•
The bar code label must start with $+ (Change Configuration command).
•
Each configuration command must include the command syntax and the value for the command. For example, BV is the command syntax for Beep Volume and the value 4 sets the beep volume to very loud.
•
If you set one configuration command to a string of ASCII characters and another configuration command follows, you must enclose the value in quotes. If you do not include the quotation marks, the terminal will interpret everything after the first command as data and will not find the second configuration command. For example, to set the preamble to BV, use $+ADBV (no quotes are needed). To set the preamble to BV and turn off the beep volume, use $+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear the preamble and postamble from a single label, use $+AD""AE. Note: To scan a Code 39 bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode.
•
To include quotation marks when you set a value, the entire value must be enclosed in quotation marks. Type two sets of quotation marks ("") to include one quotation mark as the value for a command. For example, to set the preamble to ABC"D, use $+AD"ABC""D".
When you scan bar code labels, you change the terminal’s current runtime configuration. The changes are not saved in the terminal’s flash memory. To save the changes in flash memory, scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
You can also use the TRAKKER Antares 2400 Menu System. For help, see “Saving Configuration Changes in Flash Memory” later in this chapter.
3-16
Page 107
nugget
39 Configuring the Terminal
3
Scanning Bar Codes to Enable Symbologies The TRAKKER Antares 248X terminals can decode several different types of bar code symbologies. Each symbology, such as Code 39, uses a different scheme for encoding data as bar code. You must configure the terminal to decode the bar code symbology used in your bar code labels. Only enable the bar code symbologies that you need to scan. The terminal can decode the bar code symbologies shown in the next table. You can scan the bar code labels in the table to enable a symbology. Note: Only three symbologies, Code 39, Code 128, and UPC/EAN, are enabled when you unpack the terminal. Bar Code Symbology
Enabled?
To Enable the Symbology
Codabar
No
Enable Standard Codabar, ABCD Start/Stop Code
*$+CD21* *$+CD21* Code 11
No
Enable Code 11 With Two Check Digits
*$+CG2* *$+CG2* Code 16K
No
Enable Standard Code 16K
*$+CP1* *$+CP1* Code 2 of 5
No
Enable Code 2 of 5, 3 Bar Start/Stop, Label Length of 1
*$+CC001* *$+CC001* Interleaved 2 of 5 (I 2 of 5)
No
Enable I 2 of 5, Variable Length With a Check Digit
*$+CA99* *$+CA99*
Note: You can enable either Code 2 of 5 or Interleaved 2 of 5. If you enable I 2 of 5, Code 2 of 5 is automatically disabled and vice versa.
3-17
Page 108
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Bar Code Symbology Table (continued) Bar Code Symbology
Enabled?
To Enable the Symbology
Code 39
YES
Enable Code 39 Full ASCII With No Check Digit
*$+CB111* *$+CB111* Code 49
No
Enable Code 49
*$+CJ1* *$+CJ1* Code 93
No
Enable Code 93
*$+CF1* *$+CF1* Code 128
YES
Enable Standard Code 128
*$+CH1* *$+CH1* MSI
No
Enable MSI Without Check Digits
*$+CN10* *$+CN10* Plessey
No
Enable Plessey With Reverse Start Code
*$+CI10* *$+CI10* UPC/EAN
YES
Enable UPC-A/EAN-13, UPC-E, EAN-8
*$+CE1111111* *$+CE1111111*
3-18
Page 109
nugget
39 Configuring the Terminal
3
Saving Configuration Changes in Flash Memory The TRAKKER Antares terminals use two copies of the configuration: Runtime or RAM configuration This configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration This configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the four ways you can configure the terminal and how the configuration is updated: Runtime or RAM Configuration Updated?
Boot or Flash Configuration Updated?
Using the TRAKKER Antares 2400 Menu System
Yes (see Note)
Yes (see Note)
Scanning bar code labels
Yes
No
From a host application through the serial port
Yes
No
T248X from the network (Model 200 Controller or host)
Yes
No
Configure the Terminal
Note: You are prompted to save your changes in RAM and flash as you exit the Configuration Menu and the TRAKKER Antares 2400 Menu System. Your changes are saved if you choose Yes at each screen. If you configure the terminal by scanning bar code labels, through the serial port or from the network, you may want to save the changes in flash memory using one of these methods: •
Scan or send the Save Configuration in Flash Memory reader command.
•
Use the TRAKKER Antares 2400 Menu System.
To save configuration changes using the reader command •
Scan this bar code label: Save Configuration in Flash Memory
*.+1* *.+1*
Or, send the command .+1 as the last command from the controller or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”
3-19
Page 110
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To save configuration changes using the menu system 1. Press or scan this bar code.
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears. 2. Choose System Menu and press
The System Menu appears.
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051
3. Choose the Store Configuration command and press Configuration screen appears.
The Store
STORE CONFIGURATION Store Configuration in Flash Memory
OK
CANCEL 248XU.072
4. Choose OK to save the configuration in flash memory. To exit without saving the configuration, choose Cancel. The System Menu appears.
] to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ] to exit the 5. Press
TRAKKER Antares 2400 Menu System.
3-20