Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 26

TRAKKER Antares 248X Stationary Terminal User's Manual, pages 111 to 120

Pages 111 to 120 of 255

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2480, Intermec 2481 and Intermec 2485

Page 111

nugget

39 Configuring the Terminal

3

Restoring the Terminal’s Default Configuration When you configure the terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can use the TRAKKER Antares 2400 Menu System or scan the Default Configuration bar code label to return the terminal to its default configuration. Note: If you restore the default configuration, you need to set the primary network communications parameters on the T2485 and T2486 to reestablish communications with other devices in the 2.4 GHz RF network. You may also need to reset the serial port or Ethernet parameters to communicate with other devices in your wired network. To restore the default configuration using the reader command •

Scan this bar code label: Default Configuration

*.+0* *.+0*

To restore the default configuration using the menu system 1. Press or scan this bar code:

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

The System Menu appears. 3. Choose the Load Default Values command and press The Load Default 2. Choose System Menu and press Values screen appears.

3-21

Page 112

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Load Default Values Screen LOAD

DEFAULT

VALUES

Load default configuration values in RAM? (Overwrites current configuration)

OK

CANCEL 248XU.056

4. Choose OK and press to load the default configuration values. The default values will override the current runtime configuration on the terminal. To exit without loading the default values, choose Cancel and press The System Menu appears.

] to exit the System Menu. The Main Menu appears. 6. Choose another menu from the Main Menu or press ] to exit the 5. Press

TRAKKER Antares 2400 Menu System. For help exiting the menu system, see “Exiting the TRAKKER Antares 2400 Menu System” earlier in this chapter.

Configuring Drives and Memory on the Terminal The TRAKKER Antares 248X terminals come with a 750K flash drive (C) and 512K RAM reserved for applications. You can also order a T248X with an additional 2MB extended flash memory option. You can customize the terminal to your needs by configuring • up to 256K of the 512K RAM as a RAM drive.

• the additional 2MB flash memory to either store double-byte fonts or as a 2MB drive.

The next sections explain how to customize the terminal by configuring RAM and configuring flash memory.

3-22

Page 113

nugget

39 Configuring the Terminal

3

Configuring the RAM Drive On the T248X, you have 512K total RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. For example, if your application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. By default, the RAM drive is not configured and the memory is available for applications. You can configure the size of the RAM drive (E) and use drive E to temporarily store data and files (up to 32 files). Important: After you disable or configure the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed. To configure the RAM drive

1. Press or scan this bar code to access the TRAKKER Antares 2400 Menu System: Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

248XU.001

3-23

Page 114

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Y

2. Press to choose the Configuration Menu and then press Configuration Menu appears. CONFIGURATION

The

MENU

Symbologies Menu Communications Menu Terminal Menu

⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.010

Y

3. Press to choose the Terminal Menu and then press Menu appears.

The Terminal

TERMINAL MENU Append Time Beeper Display Keypad Power Management Preamble/Postamble RAM Drive Reader Command Menu Scanner _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.037

Y

4. Press to choose the RAM Drive command and then press Drive screen appears.

The RAM

5. In the Size field, type the RAM drive size. Enter a value from 16 to 256 to configure RAM as drive E. If you do not want the terminal to create a RAM drive, enter a value of zero (0).

to save the changes and exit the RAM Drive screen. 7. Press ] to exit the Terminal Menu. The Configuration Menu appears. 8. Press ] to exit the Configuration Menu. 9. Press to choose Yes and save the new configuration in RAM. 10. Press ] to exit the TRAKKER Antares 2400 Menu System. 11. Press to choose Yes and store your changes permanently in flash 6. Press memory. The RAM drive change must be saved in flash memory for the change to take effect.

3-24

Page 115

nugget

12. Press

39 Configuring the Terminal

3 to choose OK and exit the TRAKKER Antares 2400 Menu System.

13. Scan this bar code to reset the terminal: Reset Firmware

*-.* *-.*

You can also send the Reset Firmware command over the network. For help, see Chapter 6, “Reader Command Reference.” Or, if the Resume Execution command is configured to resume “not allowed,” turn the terminal off and then back on to reset the terminal. Use the TRAKKER Antares 2400 Menu System to configure the Resume Execution command. Choose Terminal Menu from the Configuration Menu and then choose Power Management.

Configuring Flash Memory If you have a T248X with the optional 2MB extended flash memory, you can use the flash memory either to store double-byte fonts or as a 2MB drive. By default, the 2MB flash memory is configured to store a double-byte font set (up to 2MB maximum). If you are not using double-byte fonts, you can configure the 2MB flash memory as a storage drive (D). If you configure the flash memory as drive D, use this drive to store large lookup tables and data files (up to 32 files). Note: You can only configure the 2MB flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory. To configure flash memory to store double-byte fonts 1. Scan this bar code: Configure Flash Memory for Double-Byte Fonts

*$+FF0* *$+FF0*

2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

3-25

Page 116

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 3. Scan this bar code to boot the terminal and use the 2MB flash memory to store double-byte fonts: Reset Firmware

*-.* *-.*

Note: When you boot or reset the terminal, all files on drive D are destroyed. Flash memory is now configured to store double-byte fonts. 4. Use the TRAKKER Antares Font Editor to download the double-byte font set to the terminal. See your local Intermec sales representative or visit the Intermec web site (www.intermec.com) for information about the TRAKKER Antares Font Editor. To configure flash memory as drive D 1. Scan this bar code: Configure Flash Memory as Drive D

*$+FF32* *$+FF32*

Note: A value of 32 configures drive D as a 2MB drive. 2. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory

*.+1* *.+1*

3. Scan this bar code to boot the terminal and use flash memory as drive D: Reset Firmware

*-.* *-.*

Note: When you boot or reset the terminal, any fonts in flash memory are erased. Flash memory is now configured as drive D.

3-26

Page 117

nugget

39 Configuring the Terminal

3

Upgrading the Firmware The terminal firmware includes these items: •

TRAKKER Antares 2400 Menu System

•

Terminal emulation, screen mapping, or sample application

•

TE Configuration Menu (3270, 5250, VT/ANSI terminals only)

•

Operating environment, firmware, and drivers

When a new release of the firmware is available, you can order a firmware upgrade kit. There is a kit for TCP/IP terminals and a separate kit for UDP Plus terminals. To order the TRAKKER Antares Firmware Upgrade Kit, contact your local Intermec service representative. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the T248X from a host computer or PC using serial communications. For help connecting the terminal, see Chapter 2, “Installing the Terminal.” Once the terminal is connected, you can upgrade the firmware. Note: You can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the Model 200 Controller with v3.0 software and higher. For help, see the Model 200 Controller System Manual. To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. The Firmware Installation utility includes detailed online help. You click the Help button anytime to get more information. 3. Choose the COM port and the Firmware Type (application). For example, the TRAKKER Antares 2480 sample application is one firmware type. 4. On the TRAKKER Antares terminal, press code label:

or scan this bar

Enter Test and Service Mode

*..-.* *..-.*

The Main Menu appears.

3-27

Page 118

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 5. Choose System Menu and press

The System Menu appears.

SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄

_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051

6. Choose Upgrade Firmware and press appears.

The Upgrade Firmware screen

UPGRADE FIRMWARE Upgrade terminal firmware? Make sure the terminal is connected to a host computer.

OK

CANCEL 248XU.074

7. Choose OK to continue. The next screen appears. Are you want to sure you continue?

Selecting YES will upgrade and replace all of the terminal's firmware. Selecting NO will exit without upgrading firmware.

YES

NO 242XU.152

3-28

Page 119

nugget

39 Configuring the Terminal

3

8. Choose Yes to continue and upgrade the firmware. The terminal reboots and then displays the Loader Waiting screen. To exit without upgrading the firmware, choose No. Note: If you reach the Loader Waiting screen and cannot upgrade or continue, press or to exit without upgrading the firmware. The Boot Menu appears. Press to boot the terminal and continue.

] f

9. On your PC, make sure you selected the COM port and Firmware Type, and then choose OK. The PC downloads the firmware and application. Once the download is complete, the terminal boots and runs the application. Repeat these instructions to upgrade the firmware on another terminal. For help with the TRAKKER Antares firmware installation utilities, see the README.TXT instructions that ship with the utility or use the online help.

3-29

Page 120

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Recording Your Terminal’s Configuration The tables in this section list all the configuration parameters, their options, and where to find them in the Configuration Menu of the TRAKKER Antares 2400 Menu System. The default setting for each parameter is shown in bold italics. You should have an accurate record of the terminal’s configuration settings in case the terminal’s volatile memory and the configuration setup is lost. You can record the configuration on the following pages by circling the option you chose for each parameter or writing the value.

Bar Code Symbologies Table Parameter (Syntax)

Options

Location in Configuration Menu

Codabar (CD)

Disabled ABC Standard Concatenated

Symbologies Menu, Codabar option

• Start/Stop digit

Discard Retain ABCD Retain DC1-DC4

Code 11 (CG)

Disabled One check digit Two check digits

Symbologies Menu, Code 11 option

Code 16K (CP)

Disabled Standard Function code 1

Symbologies Menu, Code 16K option

Code 2 of 5 (CC)

Disabled 3 bar start/stop, label length 2 bar start/stop, label length

Symbologies Menu, 2 of 5, I2 of 5 option

Code 39 (CB)

Disabled No check digit Check digit HIBC AIAG check digit

Symbologies Menu, Code 39 option

• Check digit

Discard Retain

• ASCII

Non-full ASCII Full ASCII Mixed-full ASCII

Symbologies Menu, Code 39 option

Code 49 (CJ)

Disabled Enabled

Symbologies Menu, Code 49 option

3-30