Page 121

nugget

39 Configuring the Terminal

3

Bar Code Symbologies Table (continued) Parameter (Syntax) Code 49 (continued) • Function Code 1 (CK)

Options

Location in Configuration Menu

None (disabled) Any two ASCII characters

• Function Code 2 (CL)

\x0D\x0A (CR LF) Any four ASCII characters

• Function Code 3 (CM)

None (disabled) Any two ASCII characters

Code 93 (CF)

Disabled Enabled

Symbologies Menu, Code 93 option

Code 128 (CH)

Disabled Standard UCC/EAN-128 ISBT

Symbologies Menu, Code 128 option

• ISBT Symbology

Disabled Enabled

• ISBT Concatenated

Disabled Enabled

Interleaved 2 of 5 (CA)

Disabled Fixed length Variable length, no check digit Case Code, check digit Variable length, check digit

Symbologies Menu, 2 of 5, I2 of 5 option

MSI (CN)

Disabled No check digit 1 modulus 10 check digits 2 modulus 10 check digits

Symbologies Menu, MSI option

• Check digits

Discard Retain

Symbologies Menu, MSI option

Plessey (CI)

Disabled Discard check digit Retain check digit

Symbologies Menu, Plessey option Symbologies Menu, UPC/EAN option

UPC/EAN (CE) • UPC-A/EAN-13 (Version A)

Disabled Enabled UPC-A only

• UPC-E (Version E)

Disabled Enabled

3-31

Page 122

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Bar Code Symbologies Table (continued) Parameter (Syntax) UPC/EAN (continued) • EAN-8

Options

Location in Configuration Menu

Disabled Enabled

• Supplementals

Yes No

• Check digit

Discard Retain

• Number system digit

Discard Retain

• UPC-A leading zero

Discard Retain

RF and Ethernet Network Communications Table Note: The network parameters are different for each type of network protocol, TCP/IP or UDP Plus, loaded on the terminal. Parameter (Syntax)

Options

Location in Configuration Menu

Acknowledgement Delay Lower Limit (NV)

300 milliseconds 200 - 2000 milliseconds

Communications Menu, Advanced Network option

Acknowledgement Delay Upper Limit (NU)

5000 milliseconds 2000 - 60000 milliseconds

Communications Menu, Advanced Network option

Controller Connect Check Receive Timer (NP)

60 seconds 1 - 3600 seconds

Communications Menu, Advanced Network option

Controller Connect Check Send Timer (NQ)

35 seconds 1 - 3600 seconds

Communications Menu, Advanced Network option

Controller IP Address (NC)

0.0.0.0 The IP address field is four numbers separated by periods.

Communications Menu, Primary Network option

Default Router (NX)

0.0.0.0 The Router field is four numbers separated by periods.

Communications Menu, Advanced Network option

Host IP Address (NC)

0.0.0.0 The IP address field is four numbers separated by periods.

Communications Menu, Primary Network option

3-32

Page 123

nugget

39 Configuring the Terminal

3

RF and Ethernet Network Communications Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Maximum Retries (NR)

7 0 - 99

Communications Menu, Advanced Network option

Network Activate (NA)

Disabled 2.4 GHz RF (enabled) Ethernet

Communications Menu, Primary Network option

Network Loopback (NL)

Disabled Enabled

Communications Menu, Advanced Network option

Network Port (NG)

00023 (for TCP/IP) 05555 (for UDP Plus) 1 - 65535

Communications Menu, Advanced Network option

RF Domain (RW)

0 0 - 15

Communications Menu, Radio option

RF Inactivity Timeout (RY)

5 seconds 0 - 255 seconds

Communications Menu, Radio option

RF Roaming Flag (RR)

Allowed Not allowed

Communications Menu, Radio option

RF Security ID (RS)

None (no characters) Any 20 ASCII characters

Communications Menu, Radio option

RF Transmit Mode (RT)

BFSK QFSK Auto

Communications Menu, Radio option

RF Wakeup On Broadcast (RB)

Disabled Enabled

Communications Menu, Radio option

Subnet Mask (NS)

255.255.255.0 The Subnet Mask field is four numbers separated by periods. Each number is from 0 to 255.

Communications Menu, Advanced Network option

TCP/IP Maximum Transmit Timeout (NH)

0 (No timeout) 30 - 120 seconds 32 seconds

Communications Menu, Advanced Network option

Terminal IP Address (ND)

0.0.0.0 The IP address field is four numbers separated by periods.

Communications Menu, Primary Network option

3-33

Page 124

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Serial Network Communications Table Parameter (Syntax)

Options

Location in Configuration Menu

Baud Rate (YA)

1200 2400 4800 9600 19200 38400

Communications Menu, Serial Port options

Configuration Commands Via Serial Port (YT)

Disabled Enabled with TMF Enabled without TMF

Communications Menu, Serial Port options

Data Bits (YI)

7 8

Communications Menu, Serial Port options

EOM (YZ)

\x03 (ETX) Any two ASCII characters

Communications Menu, Serial Port options

Flow Control (YL)

None CTS checking XON/XOFF response XON/XOFF control XON/XOFF response & control CTS/RTS on DTE/DTE

Communications Menu, Serial Port options

Handshake (YJ)

Disabled Enabled

Communications Menu, Serial Port options

LRC (YF)

Disabled Enabled

Communications Menu, Serial Port options

Multi-Drop Address (YN)

A Any ASCII character

Communications Menu, Serial Port [COM2] options

Parity (YB)

None Even Odd

Communications Menu, Serial Port options

Poll (YR)

Disabled Enabled

Communications Menu, Serial Port options

Protocol (YU)

Configurable Polling Mode D Master Polling Binary Multi-drop (COM2 only)

Communications Menu, Serial Port options

SOM (YY)

\x02 (STX) Any ASCII character

Communications Menu, Serial Port options

Stop Bits (YC)

1 2

Communications Menu, Serial Port options

3-34

Page 125

nugget

39 Configuring the Terminal

3

Serial Network Communications Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Timeout Delay (YE)

5 milliseconds 100 milliseconds 500 milliseconds 2 seconds 10 seconds 20 seconds 40 seconds 60 seconds

Communications Menu, Serial Port options

Parameter (Syntax)

Options

Location in Configuration Menu

Append Time (DE)

Disabled Enabled

Terminal Menu, Append Time option

Automatic Shutoff (EZ)

0 (disabled) 2 - 75 minutes

Terminal Menu, Power Management option

Beep Volume (BV)

Off Quiet Normal Loud Very loud

Terminal Menu, Beeper option

Decode Security (CS)

Low Moderate High

Terminal Menu, Scanner option

Display Contrast (DJ)

0-7 3

Terminal Menu, Display option

Display Font Type (DT)

8x8 (T2481 and T2486 only) 8x16 16x16

Terminal Menu, Display option

Display Row Spacing (DL)

0-8 0 (T2481 and T2486) 7 (T2480 and T2485)

Terminal Menu, Display option

Display Video Mode (DN)

Original Normal Inverse

Terminal Menu, Display option

Keypad Caps Lock (KA)

On Off

Terminal Menu, Keypad option

Keypad Clicker (KC)

Disabled Enabled

Terminal Menu, Keypad option

Terminal Operations Table

3-35

Page 126

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Terminal Operations Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Keypad Table (KT)

Hardware default English QWERTY IBM 5250 IBM 3270 ANSI/VT Function numeric French AZERTY Italian QWERTY Spanish QWERTY German QWERTZ Portuguese QWERTY

Terminal Menu, Keypad option

Postamble (AE)

None (no characters) Any 25 ASCII characters

Terminal Menu, Preamble/Postamble option

Preamble (AD)

None (no characters) Any 25 ASCII characters

Terminal Menu, Preamble/Postamble option

RAM Drive Size (FR)

0 (disabled) 16 - 256K

Terminal Menu, RAM Drive option

Reader Commands (DC)

Disable all reader commands Enable all reader commands Enable override Disable override

Terminal Menu, Reader Commands option

• Enable/Disable specific Reader Commands

Abort Program Backlight Backspace Change Configuration Clear Default Configuration Delete File Enter Accumulate mode Exit Accumulate mode List Files Multiple-Read Labels Receive File Rename File Reset Run Program Scanner Trigger Off Scanner Trigger On Test & Service mode Transmit File

Terminal Menu, Reader Commands option, Enable single commands option

Resume Execution (ER)

Not Allowed Allowed

Terminal Menu, Power Management option

3-36

Page 127

nugget

39 Configuring the Terminal

3

Terminal Operations Table (continued) Parameter (Syntax)

Options

Location in Configuration Menu

Scan Ahead (SD)

Disabled Enabled

Terminal Menu, Scanner option

Scanner Mode (SB)

One-Shot mode Automatic mode

Terminal Menu, Scanner option

Scanner Redundancy (SR)

None Normal High

Terminal Menu, Scanner option

Scanner Selection (SS)

All compatible scanners 146X CCD scanners 151X laser scanners 1545 laser scanner Symbol scanners 155X laser scanners

Terminal Menu, Scanner option

Scanner Timeout (SA)

Disabled (0) 1 - 60 seconds

Terminal Menu, Scanner option

Scanner Trigger (SC)

Level Edge

Terminal Menu, Scanner option

Time in Seconds (DA)

Disabled Enabled

Terminal Menu, Append Time option

3-37

Page 128

This page is a scan with no text; see it in the PDF.

Page 129

4 Operating the Terminal in a Network

Page 130

This page is a scan with no text; see it in the PDF.