The text of a manual · part 14 of 26

TRAKKER Antares 248X Stationary Terminal User's Manual, pages 131 to 140

Pages 131 to 140 of 255

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2480, Intermec 2481 and Intermec 2485

Page 131

nugget

39 Operating the Terminal in a Network

4

This chapter describes serial networks, the 2.4 GHz RF network, and the Ethernet network and explains how the TRAKKER Antares 248X terminal fits into your network. It also explains how to install and configure the terminal, use serial or network communications, configure the T248X over the network, and it provides technical details about network connectivity and protocols.

Using Serial Communications on the Terminal The TRAKKER Antares 248X terminals have one or more serial ports to transfer data to and from another device via serial communications. Before you can use the serial port, you need to connect and configure the terminal. The next sections cover these topics: •

How the T248X Fits Into Your Serial or CrossBar Network

•

Identifying the COM Ports

•

Choosing a Communications Protocol

•

Configuring the Serial Port Parameters

•

Configuring the Terminal Via the Serial Port

How the T248X Fits Into Your Serial or CrossBar Network The TRAKKER Antares 248X terminal is a versatile terminal that you can easily add to your network or distributed data collection system. You can use the T2480, T2481, T2485, or T2486 as an end device in your wired network. Every terminal has one serial port (COM1) to transmit data to and from a PC via RS-232 serial communications. Mainframe

File server

CRT Terminals Ethernet

RS-232 cable

PC

T2485/6 248XU.162

4-3

Page 132

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

TRAKKER Antares Terminals in an Intermec CrossBar Network Host

9154/9161

T248X

Printer

T248X

9560

248XU.039

9560

Printer

With the enhanced input/output board, the terminal has a additional serial port (COM2) that supports RS-232/422/485 communications. You can use COM2 to connect to a serial device (for example, a printer), a wired network, or an Intermec CrossBar network. In a CrossBar network, the T248X transfers data to the 9154 or 9161 controller using Multi-Drop protocol. You can also attach an adapter cable accessory (Part No. 067185) to the enhanced input/output board to use an additional serial port (COM4) for RS-232 serial communications.

4-4

Page 133

nugget

39 Operating the Terminal in a Network

4

Identifying the COM Ports Communications ports, also called COM ports, are locations from which data can be passed into and out of the terminal. The illustration identifies the COM ports on the terminal. The next table explains the COM port designations to use when developing client/server applications. NET (RF) port

T2480/1

T2485/6 Same COM ports as T2480/1

TRAKKE 2486 R Antares es c Q W ta I/O

E

A

?

Ca

R ps

S

COM1

, .

U

G

C F7

F2

/ Y

F

X

F1

NET (Ethernet) port

\ T

D

Z F6

I

H

V

F9

P

K

N

F3

+ O

J

B

F8 bk

M sp

L

&

: F4

F1

0

F5

COM2

Ct

7 rl

*

8

$ Fn

L Fn f

4

9

%

R

5 f En ter

1

6

@

2

<

#

Ins

3 0

De l

>

.

COM4 248XU.096

Port

COM Port Designation for Applications

COM1

Use for RS-232 serial port communications on the T2480, T2481, T2485, or T2486.

COM2

Use for RS-232/422/485 serial port communications on the T2480, T2481, T2485, or T2486 with an enhanced input/output board.

COM4

Use for RS-232 serial port communications on the T2480, T2481, T2485, or T2486 when an adapter cable is attached to the COM4 connector on an enhanced input/output board.

NET

Use for RF communications on the T2485 or T2486, or for Ethernet communications on the T2480 or T2481 with an Ethernet card. The TRAKKER Antares PSK functions use NET to designate the RF or Ethernet network port.

You can physically connect the T248X to another device (host computer, printer, controller, or other serial device) by using one of the serial COM ports. For help connecting to a serial port, see Chapter 2, “Installing the Terminal.”

4-5

Page 134

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Choosing a Communications Protocol Once the T248X is connected to a host computer or other serial device, you are ready to configure the serial port parameters on the two devices. The terminal uses a communications protocol and XMODEM or YMODEM to handle data communications through the serial ports. You can configure a different communications protocol for each COM port. The terminal’s built-in file operations use XMODEM or YMODEM for file transfer. Communications protocols determine exactly how data is transmitted between the terminal and the connected device. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the connected device must use the same protocol and parameter settings to communicate properly. For help on protocols, see the Data Communications Reference Manual. The terminal can communicate in these five protocols: •

Binary

•

Configurable protocol

•

Multi-Drop (COM2 only)

•

Master Polling

•

Polling Mode D

Each protocol is described next.

Binary Protocol Binary protocol has no protocol. Characters are sent and received without being altered. The Data Link Escape character (DLE) is not inserted before any character. DLE characters are not stripped out of the incoming data stream and no characters such as EOM or SOM are added. Here are the serial port parameters you can define: •

Baud rate

•

Data bits

•

Parity

•

Stop bits

•

Flow control

Configurable Protocol Configurable protocol is based on Intermec’s Polling Mode D protocol except that you have the option to change some of the serial port protocol parameters or remove specific events from the protocol, such as Poll or handshake. Here are the serial port parameters you can define: •

4-6

Baud rate

Page 135

nugget

39 Operating the Terminal in a Network

•

Data bits

•

Parity

•

Stop bits

•

Configuration commands via serial port

•

EOM (End of Message)

•

Flow control

•

Handshake (enabled or disabled)

•

LRC

•

Poll (Polling) (enabled or disabled)

•

SOM (Start of Message)

•

Timeout Delay

4

Configurable protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. Once EOM is enabled, you can set a value for these serial port parameters: •

Configuration commands via serial port

•

Handshake

•

LRC

•

SOM

Once Handshake is enabled, you can set a value for poll and the timeout delay. You can only enable flow control with XON/XOFF control when the terminal is communicating in Character mode. Flow control with CTS is allowed in either Character or Frame mode.

Multi-Drop Protocol Multi-drop uses protocol sequences similar to Polling Mode D with the extension of device addressing, which allows up to 32 devices on one 4-wire RS-485 line. Multi-Drop protocol is typically used in CrossBar networks. Due to timeout parameters, the baud rate must be 2400 or higher. Multi-Drop protocol is only available for COM2. When you configure COM2 for Multi-Drop protocol, the serial port is automatically configured to communicate via RS-422/485. If COM2 is not configured for Multi-Drop protocol, the port communicates via RS-232. Here are the serial port parameters you can define: •

Baud rate

•

Multi-drop device address

4-7

Page 136

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Master Polling Protocol Master Polling Mode D protocol requires the TRAKKER Antares terminal to ask the downline serial device for data it may have (polling) and to request to send data to the serial device (selecting). There is no automatic polling, so your application must poll periodically for data. Before each transmit operation, the terminal issues the SEL sequence for the device addressed and sends the data if an acknowledge is received. Before each receive operation, the terminal issues a poll sequence and waits for data or the RES character (no data is available to send ). Here are the serial port parameters you can define: •

Baud rate

•

Flow control

Polling Mode D Protocol Polling Mode D requires the host computer to ask the terminal for data it may have (polling) and to request to send data to the terminal (selecting). Polling Mode D uses an RS-232 interface. Here are the serial port parameters you can define: •

Baud rate

•

Flow control

Configuring the Serial Port Parameters The values you set for the terminal serial port must match the values set for the serial port on the connected device. There are three ways to configure the terminal’s serial port parameters: •

Use the TRAKKER Antares 2400 Menu System. For help on configuring the parameters, see “Configuring the Serial Port Parameters” in Chapter 2.

•

Scan the configuration command from a Code 39 or Code 93 bar code label.

•

Send a command from an application through the serial port on the host computer. For help, see the next section, “Configuring the Terminal Via the Serial Port.”

If you are configuring the serial port parameters in the TRAKKER Antares 2400 Menu System, you may not see all of the serial port parameters until you set a value for another key field. For example, EOM is a key field when you configure the Configurable protocol. Several fields are invalid (do not appear) until you enable EOM. If you are configuring the serial port parameters by scanning or sending configuration commands, the terminal will accept and set all serial port commands. However, the terminal only uses the parameters that are valid for the current protocol configuration. For example, if you are using Configurable

4-8

Page 137

nugget

39 Operating the Terminal in a Network

4 protocol on COM1, you can set a value for poll, but the terminal will not use it if handshake is not enabled. Once the terminal is connected and configured, you can transfer data between the terminal and the device that is connected to the serial port. For help transferring files, see Chapter 5, “Using Custom Applications and Screen Mapping.”

Configuring the Terminal Via the Serial Port You can use an application on the PC or host to configure the TRAKKER Antares 248X terminal by sending commands through the serial port. For example, you may want to change the Beep Volume command and the Keypad Caps Lock command. To send and receive configuration data, you need to write an application for the host that can communicate with the terminal through the serial port. You must connect the terminal to the host by using one of the serial ports. Once the terminal is communicating, you can configure it. If you are using the Configurable protocol, you must enable Frame mode and the Configuration Commands Via Serial Port command to configure the terminal through the serial port. You cannot configure the terminal through the serial port if you are using Configurable protocol with no EOM or Binary protocol on that port. Note: You can continue running an application on the TRAKKER Antares terminal while configuring the terminal from the host. If you send a configuration command that changes the serial port parameters, you may not be able to continue sending commands unless you also reconfigure your host. To set up the application •

Prepare and write a host application that can send transactions to and receive transactions from the terminal in this format: [SOM]

[TMF field] configuration command

EOM where: [SOM] is the start of message field.

[TMF field] is only used if you are using the Configurable protocol and the Configuration Commands Via Serial Port are enabled with TMF (Terminal Message Format). It is a 2-byte field containing one of these values: CG

Configuration Get request sent from the host application.

4-9

Page 138

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 [TMF field] (cont.)

Cg CS Cs

Configuration Get response sent from the terminal to the host. Configuration Set request sent from the host application. Configuration Set response sent from the terminal to the host.

Note: If the Configuration Commands Via Serial Port are enabled without TMF or you are using a protocol other than Configurable, do not include this field. configuration command is the reader or configuration command or commands you want to set on the terminal, or get the current value of from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command. For a list of commands, see Chapter 6, “Reader Command Reference.”

EOM is the end of message field.

Note: To send data to an application instead of sending configuration commands, use the letter A followed by a space in the TMF field. If the TMF field does not contain CG, Cg, CS, Cs, or A, the terminal ignores the transaction. Example with TMF In the host application, you want to set the value for two configuration commands on the terminal. Send this transaction from the host application: CS$+BV4KA1.+1

Note: SOM and EOM are not shown in this example. where: CS is a TMF Configuration Set request.

$+ is the Change Configuration reader command.

BV4 sets the Beep Volume configuration command to a value of 4, which is a very loud beep volume.

KA1 enables the Keypad Caps Lock configuration command.

.+1 is the reader command that saves configuration changes to the terminal’s flash memory.

The terminal returns this transaction to the host application. Cs$+BV4KA1.+1

4-10

Page 139

nugget

39 Operating the Terminal in a Network

4 where: Cs is a TMF Configuration Set response.

$+ is the Change Configuration reader command.

BV4 means the Beep Volume configuration command was changed to a value of 4, which is a very loud beep volume.

KA1 means the Keypad Caps Lock configuration command was enabled.

.+1 means the configuration changes were saved in flash memory.

Using RF or Ethernet Communications on the Terminal Before you can begin using the TRAKKER Antares 248X terminal to collect data, you need to install and configure each device in the 2.4 GHz RF or Ethernet network by performing these steps: 1. Plan and prepare your network. Make sure you have unique IP addresses for all devices in the network. Make sure you have all the equipment required to use the: • •

T2480 or T2481 with an Ethernet card in the Ethernet network. T2485 or T2486 in the RF network.

2. Configure the Model 200 Controller (T248X with UDP Plus). 3. Configure the access points. 4. Configure each T248X terminal. Each step is described in detail in the next sections. Caution Make sure all components with antennas are at least 1 foot (0.3 meters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d'au moins un pied (0.3 mètres) avant de faire la connexion avec l'alimentation électrique, faute de quoi vous risquez d'endommager votre installation.

How the T248X Fits Into Your RF or Ethernet Network The TRAKKER Antares 248X terminal is a versatile terminal that you can easily add to your network or distributed data collection system. You can use the T2480 or T2481 with an Ethernet card option as an end device in your Ethernet network. You can use the T2485 or T2486 as an end device in Intermec’s 2.4 GHz RF network. The illustrations in this section show some examples of the types of network configurations in which you can use the terminal.

4-11

Page 140

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

TRAKKER Antares 2485 and 2486 Terminals in a 2.4 GHz RF Network Host TCP/IP Direct Connect

UDP Plus

Ethernet

Access point

T2485/6

Access point

Model 200 Controller

T2485/6

T2485/6

T2485/6

248XU.231

In a UDP Plus network, the T2485/6 communicates with a host computer through the Model 200 Controller using UDP Plus for the RF protocol. In a TCP/IP direct connect network, the T2485/6 communicates with a host computer directly using TCP/IP for the RF protocol. The access point acts as a bridge to allow communications between the Ethernet or token ring network and the wireless T2485/6 terminals.

TRAKKER Antares 2480 and 2481 Terminals in an Ethernet Network Host TCP/IP

UDP Plus

Ethernet

Model 200 Controller T2480/1

T2480/1

T2480/1

T2480/1 248XU.100

4-12