Page 141

nugget

39 Operating the Terminal in a Network

4

In a UDP Plus network, the T2480/1 with an Ethernet card communicates with a host computer through the Model 200 Controller using UDP Plus for the network protocol. In a TCP/IP network, the T2480/1 with an Ethernet card communicates with a host computer directly using TCP/IP for the network protocol.

TRAKKER Antares 2485 and 2486 Terminals in Multiple Subnetworks (UDP Plus) Model 200 Controller 192.9.175.7 Router

Access point

T2485/6 terminals 192.9.200.5, 192.9.200.6

Ethernet

T2485/6s cannot roam between subnetworks

192.9.200.X subnetwork

Access point

192.9.175.X subnetwork

Access point

T2485/6 terminals 192.9.175.10 192.9.175.11

248XU.091

You can install the TRAKKER Antares 2485 or 2486 terminals, access points, and Model 200 Controller in your 2.4 GHz RF network as shown in the illustration. The T2485/6 terminals may only communicate with the access points that are in the same IP subnetwork. In this example, all the terminals and access points communicate with the controller at IP address 192.9.175.7 using UDP Plus for the RF protocol.

4-13

Page 142

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

TRAKKER Antares 2485 and 2486 Terminals in Multiple Subnetworks (TCP/IP) Host

192.9.175.7

Router

Access point

T2485/6 terminals 192.9.200.5, 192.9.200.6

Ethernet

T2485/6s cannot roam between subnetworks

192.9.200.X subnetwork

Access point

192.9.175.X subnetwork

Access point

T2485/6 terminals 192.9.175.10 192.9.175.11

248XU.169

You can install the TRAKKER Antares 2485 or 2486 terminals and access points in your 2.4 GHz RF network as shown in the illustration. The T2485/6 terminals may only communicate with the access points that are in the same IP subnetwork. In this example, all the terminals and access points communicate with the host at IP address 192.9.175.7 using TCP/IP for the RF protocol.

4-14

Page 143

nugget

39 Operating the Terminal in a Network

4

TRAKKER Antares 248X Terminals Communicating Across Subnetworks (UDP Plus) Model 200 Controller 192.9.200.5

T2480/1 192.9.175.8

Router

192.9.175.X subnetwork

192.9.200.X subnetwork

Ethernet

192.9.175.1

Access point T2485/6 terminals 192.9.175.9 192.9.175.10 192.9.175.11

248XU.092

You can install the T248X terminals and access points in one IP subnetwork and install the Model 200 Controller in another IP subnetwork as shown in the illustration. If you have a T2480 or T2481 with an Ethernet card, you can install the T2480/1 in one IP subnetwork and install the controller in another IP subnetwork as shown in the illustration. In this network, you must configure additional network parameters (default router and subnet mask) as described later in this chapter. Note: All access points that the TRAKKER Antares 2485 or 2486 terminal may communicate with and roam between must be on the same IP subnetwork. The terminal cannot roam between IP subnetworks.

4-15

Page 144

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Planning the Network Connection To use the T2480 or T2481 with an Ethernet card in the Ethernet network, you need these minimum requirements: • •

Model 200 Controller (only T2480 or T2481 with UDP Plus) Ethernet jack or connector in your network

To use the T2485 or T2486 in the 2.4 GHz RF network, you need these minimum requirements: • •

Model 200 Controller (only T2485 or T2486 with UDP Plus) Access point

When you first consider purchasing a wireless data collection system, an Intermec representative works with you to perform a site survey at your facility. The site survey analyzes the range of radio frequency devices in your facility and determines the placement of the access points. The site survey ensures that the coverage of each access point overlaps to provide uninterrupted wireless access at any location within the building. This manual assumes that a site survey is complete and the access points are installed in your facility. You need to work with your network administrator to plan and assign the IP address for each device in the 2.4 GHz RF or Ethernet network. You must assign and set the IP address for each access point (RF) and each T248X terminal. For a T248X with UDP Plus, you must also assign an IP address to the Model 200 Controller.

Configuring the Model 200 Controller The Model 200 Controller supports and manages communications with other devices in the 2.4 GHz RF network or Ethernet network. When you install and configure the controller, you identify the host computer(s) and TRAKKER Antares 248X terminals in your network. The terminals communicate through the controller with your host by using UDP Plus protocol. For help installing the controller, see the Model 200 Controller System Manual (Part No. 063439). Note: You can use a T248X running TCP/IP protocol and the Model 200 Controller in a pass-through network. You establish a direct TCP/IP socket connection from the T248X to the host through the controller. For more information, see the Model 200 Controller System Manual. To have the T248X communicate with the controller, you must configure these parameters on the controller:

4-16

•

Configure the UDP Plus network.

•

Assign an IP address to each T248X.

•

Enable all T248X terminals.

Page 145

nugget

39 Operating the Terminal in a Network

4

•

Define the host environment parameters, which includes configuring for terminal emulation, screen mapping, or client/server applications.

•

Define the host communications parameters, which includes the physical connection (network adapter cards) to the host.

To use the screen mapping application on the T248X, you must also configure the following: •

Create the script file using the Script Builder tool on the controller.

•

Generate the template to download to the T248X.

Configuring the Access Point The access point acts as a bridge to provide RF communications between the TRAKKER Antares 2485 or 2486 terminal and the Model 200 Controller or host. For help, see your access point user’s manual. Note: All access points that the TRAKKER Antares 2485 or 2486 terminal may communicate with and roam between must be in the same IP subnetwork. To have the T2485 or T2486 communicate with the access point, you must know the value of these parameters on the access point: •

RF domain

•

RF security identification (ID) (optional)

Configuring the T248X When you install the TRAKKER Antares 248X terminal in a network, you must configure a set of network parameters that control how the terminal communicates in the network. There are two ways to configure the network parameters: •

Use the TRAKKER Antares 2400 Menu System. For help on configuring the network parameters, see Chapter 2, “Installing the Terminal.”

•

Scan the configuration command from a Code 39 or Code 93 bar code label.

The set of network parameters you must configure depends on whether you install the terminal on the same IP subnetwork as the Model 200 Controller or host (TCP/IP), or on a different subnetwork. The next table lists the parameters you configure in each type of network.

4-17

Page 146

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Same IP Subnetwork?

Different IP Subnetwork?

Time and date

X

X

Network activate

X

X

Controller IP address (UDP Plus)

X

X

Host IP address (TCP/IP)

X

X

Terminal IP address

X

X

Network port

X

X

RF domain

X

X

Optional

Optional

Network Parameters

RF security ID Default router

X

Subnet mask

X

The network parameters are defined in the next section.

Defining the Network Parameters This section defines the network parameters you configure when installing the TRAKKER Antares 248X terminal in an RF or Ethernet network. Time and Date When you turn on the terminal for the first time, you must set the current time and date. You also need to set the time and date any time you lose all power to the terminal. For help, see “Setting the Time and Date” in Chapter 2. Network Activate On a T2480 or T2481 with an Ethernet card, the Network Activate command disables or enables Ethernet communications. On a T2485 or T2486, the Network Activate command disables or enables RF communications. If the Network Activate parameter is disabled, the network is disabled, no RF or Ethernet communications are provided. The radio is turned off on a T2485 or T2486. When the Network Activate parameter is enabled, the T248X will try to connect to the access point or Model 200 Controller. Controller IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Controller IP Address identifies the IP address assigned to the Model 200 Controller in a UDP Plus network. Host IP Address An IP address is a unique network level address you assign to each device in a TCP/IP direct connect network. The Host IP Address identifies the IP address assigned to the host in your 2.4 GHz RF or Ethernet network. Terminal IP Address An IP address is a unique network level address you assign to each device in a TCP/IP network. The Terminal IP Address identifies the IP address assigned to the T248X. The IP address you set on the terminal must match the address that is set for the terminal on the Model 200 Controller.

4-18

Page 147

nugget

39 Operating the Terminal in a Network

4

Network Port Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your 2.4 GHz RF network or your Ethernet network. In a UDP Plus network, the network port you set on the T248X must match the network port that is set on the Model 200 Controller. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the T248X. The default network port of 23 enables VT/ANSI Telnet communications. RF Domain T2485 and T2486 only. The domain defines a logical partition or subnetwork of the network. To establish communications, you must assign the same domain number to every RF device in a wireless network. The domain number you set on the terminal must match the domain that is set on each access point the terminal may communicate with. You can continue to collect data with the terminal as you roam between access points as long as all the devices have the same domain number. RF Security Identification (ID) T2485 and T2486 only. This optional parameter defines the password you can set for secured transmission and receipt of data between devices in the wireless network. To communicate, each access point and terminal must have matching security IDs. If the security ID is set on the access point, you must also set the security ID on each T2485 or T2486 that may communicate with the access point. Note: The Network Activate command must be configured to 2.4 GHz RF network before you can save any changes to the RF security ID parameter. Default Router Provides a software and hardware connection between two or more networks that permits traffic to be routed from one network to another on the basis of the intended destinations of that traffic. When the Model 200 Controller (UDP Plus) or host (TCP/IP) is on a different subnetwork than the T248X, you need to set the default router IP address. The terminal uses the router address to send packets across the network to the controller or host. The default router must have an IP address on the same subnetwork as the terminal. The default of 0.0.0.0 means there is no default router. Subnet Mask The subnet mask is an internal TCP/IP protocol stack variable that is used in IP protocol to identify the subnetwork for an IP address. The IP protocol performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the controller (UDP Plus) or host (TCP/IP) and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the controller or host, then you must set the subnet mask and default router. For example, if the terminal IP address is 192.9.150.184 and the subnet mask is 255.255.255.0, the terminal is on the subnetwork 192.9.150.0.

4-19

Page 148

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Using the Status Lights to Monitor Network Communications Once you have configured the devices in the 2.4 GHz RF or Ethernet network, you can begin using the application on the TRAKKER Antares 248X to collect and transmit data via network communications. If the T248X is communicating with your host computer, the terminal will connect and begin running the application that shipped on the terminal. You can begin using the terminal to collect data. As you use the T248X terminal to collect data, status lights help you monitor RF and network communications on the terminal. Use the Network Connect and Transmit status lights to monitor communications between the T248X and other devices in the 2.4 GHz RF or Ethernet network.

248XU.098

Using the Status Lights to Monitor Network Communications You See These Lights

Status of Communications

What You Need to Do

Network Connect status light is turned off.

No communications.

You may need to enable the Network Activate command. Make sure the terminal is configured correctly to communicate in your network. For help, see “Configuring the T248X” earlier in this chapter.

The T2480 or T2481 with an Ethernet card is not connected to the Ethernet network. The T2485 or T2486 is not connected to an access point.

4-20

In an RF network, make sure the access points are turned on and operating. You may also be using the terminal out of the RF range of an access point. Try moving closer to an access point to re-establish communications.

Page 149

nugget

39 Operating the Terminal in a Network

4

Using the Status Lights to Monitor Network Communications (continued) You See These Lights

The Network Connect status light blinks.

Status of Communications

What You Need to Do

Partial communications.

You may need to configure the terminal to communicate with other devices in the 2.4 GHz RF or Ethernet network. For help, see “Configuring the T248X” earlier in this chapter.

The T248X with UDP Plus is trying to establish communications with the Model 200 Controller, but it is not connected. Note: The Network Connect status light does not blink on a T248X with the TCP/IP protocol.

If the T2485 or T2486 is configured, you may be out of range of an access point, you may be about to go out of range of an access point, or the access point may have recently been turned off. You may also need to configure the controller (UDP Plus) or host. Make sure the terminal is configured correctly and enabled. Make sure the controller is turned on and data collection is started.

The Network Connect status light remains on.

The Network Transmit status light remains on and the Network Connect status light is turned on.

Normal communications. The T248X can communicate with the Model 200 Controller (UDP Plus or host (TCP/IP).

You can send and receive data between the terminal and the controller or host.

Normal communications.

You can send and receive data between the terminal and the Model 200 Controller or host.

The T248X is sending data or has received data for an application from the Model 200 Controller or host. The data is stored in the terminal’s network buffer until the application is ready to process the data.

4-21

Page 150

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Using the T2485 or T2486 Between Access Points The access point acts as a bridge to provide communications between the TRAKKER Antares 2485 and 2486 terminals and the Ethernet or token ring network. You may have multiple access points in your 2.4 GHz RF network to provide uninterrupted wireless communication at any location within your facility. To use the terminal between access points and continue sending and receiving data, you must follow these guidelines: •

The radio coverage of each access point must overlap to ensure that the roaming T2485 or T2486 will always have a connection available.

•

You configure each access point with the same RF domain number and security ID.

•

You configure the T2485 or T2486 terminals with the same RF domain and security ID as the access points to which they may communicate.

•

All access points that the T2485 or T2486 terminals may communicate with and roam between must be installed in the same IP subnetwork. The T2485 or T2486 cannot roam between IP subnetworks.

Once the network is configured, you can collect data anywhere within range of the access points in the wireless network. When you move out of range of one access point, the terminal automatically polls the other access points in the same RF domain to continue the network connection. If you are out of range of all access points in the network, the data is stored in the terminal’s radio buffer. The Network Transmit status light turns on. You can continue to collect data until the radio buffer is full. When the buffer is full, the application displays a communication timeout status. When you move back into range and network communications are re-established, the data in the radio buffer is transmitted to the access point and you can once again transmit data. In a TCP/IP direct connect network with a terminal running a terminal emulation application, the application may disconnect from the host if you remain out of communications range too long or if the host sends “Keep Alive” messages while the terminal is in Suspend mode. You may need to restart the application and log back into the host to re-establish a terminal emulation session. In a UDP Plus network, the session is maintained any time the terminal is out of range or in Suspend mode.

4-22