The text of a manual · part 8 of 26
TRAKKER Antares 248X Stationary Terminal User's Manual, pages 71 to 80
Pages 71 to 80 of 255
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2480, Intermec 2481 and Intermec 2485
Page 71
nugget
39 Installing the Terminal
Y
2. Press to choose the System Menu and then press appears.
2
The System Menu
SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.051
Y
3. Press to choose the Set Time and Date command and then press Time and Date screen appears.
The
TIME AND DATE Current time is 12:00:00 New time: 12:39:00 Current date is 1996/01/01 New date YYYY/MM/DD:
OK
CANCEL 248XU.009
4. Type the current time in the format HH MM SS (hours, minutes, seconds) with a space character ( ) between each field and then press . The program fills in the colon character in the time field.
Y
For example, to enter the time 04:05:03 P.M., type:
Y
Note: The time is not actually updated until you exit the Time and Date screen. When you set the time, set the time ahead so that the correct time is saved when you exit the screen in Step 6. 5. Type the current date in the format YYYY MM DD (year, month, day) with a space character ( ) between each field and then press . The program fills in the slash character in the date field.
Y
2-29
Page 72
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 For example, to enter the date August 9, 1998, type:
Y 6. Press to save the changes and exit the Time and Date screen. 7. Press ] to exit the System Menu. The Main Menu appears. 8. If you want to configure a serial port, continue with the next section, “Configuring the Serial Port Parameters.” If you want to configure a T2480 or T2481 with Ethernet, follow the instructions for “Configuring the Ethernet Parameters” later in this chapter. If you have a T2485 or T2486, follow the instructions for “Configuring RF Communications” later in this chapter.
Configuring the Serial Port Parameters You use the terminal’s serial ports to transfer data between the terminal and a serial device. Every T248X has one serial port (COM1) that supports RS-232 communications. You can use COM1 to connect to a serial device, such as a printer, modem, or PC. The terminal also has an option for two additional serial ports. COM2 supports RS-232/422/485 communications. You can use COM2 to connect to a serial device, a wired network, or an Intermec CrossBar network. COM4 supports RS-232 communications. You must first select the communications protocol for each COM port. Depending on the protocol, you need to set some or all of these serial port parameters to have the terminal communicate with a host computer or serial device in a wired network:
2-30
Serial Port Parameter
Default Value
Baud rate
19200
Commands via serial port
Enabled without TMF
Data bits
7
EOM (End of Message)
\x03 (hexadecimal ASCII value for ETX)
Flow control
None
Handshake
Disabled
LRC
Disabled
Parity
Even
Poll (Polling)
Disabled
Protocol
Configurable
SOM (Start of Message)
\x02 (hexadecimal ASCII value for STX)
Stop bits
1
Timeout delay
10 seconds
Page 73
nugget
39 Installing the Terminal
2
The values you set for the terminal’s serial port must match the values set for the host’s (or other device’s) serial port. In a CrossBar network, you also need to configure your 9154 or 9161 controller to add the new multi-drop T248X device. For help, see your controller user’s manual. You use the TRAKKER Antares 2400 Menu System to set the parameters on the terminal. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” To set the serial port parameters
_ Y
1. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.
Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.
CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.217
Y
2. Press to choose the Communications Menu and then press Communications Menu appears.
The
T2485/6 Communications Menu
T2480/1 Communications Menu
COMMUNICATIONS
COMMUNICATIONS
MENU
Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM2] Serial Port [COM4]
Serial Serial Serial
Port Port Port
MENU
[COM1] [COM2] [COM4]
⁄ ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.036
2-31
Page 74
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Note: If you have a T2480/1 with the Ethernet option, the Communications Menu is just like the T2485/6 menu except that there is no Radio command.
Y
3. Press to choose a Serial Port (COM1, COM2, or COM4) and then press . The Serial Port screen appears.
COM1 and COM2 Serial Port SERIAL
PORT
COM4 Serial Port SERIAL
[COM1]
PORT
[COM4]
Protocol: Configurable Baud Rate: 19200 Parity: Even Data Bits: 7 Stop Bits: 1
Scanner Port: Scanner Enabled Protocol: Configurable Baud Rate: 19200 Parity: Even Data Bits: 7 Stop Bits: 1
`
` more more 242XU.156
4. You must first select the protocol for each COM port. When you select a protocol, the serial port parameters screen changes to display the parameters that you can set for each protocol. For COM1 and COM4, you can select one of these protocols: • • • •
Configurable Polling Mode D Master Polling Binary
Important: For COM4, you must set the Scanner Port field to Scanner Enabled. Scanner enabled lets you use COM4 and an input device connected to the external scanner connector at the same time. For COM2, you can select one of these protocols: • • • • •
Configurable Multi-drop (CrossBar network) Polling Mode D Master Polling Binary
`
Press to toggle through the protocol options and select a value. Press to move to the next field. For more information about protocols, see Chapter 4, “Operating the Terminal in a Network.”
2-32
Y
Page 75
nugget
`
39 Installing the Terminal
2
5. In each field, press to toggle through the field options and select a value. Once the correct value is displayed, press to move to the next field. Or, enter a value in the field.
Y
You must set each of the terminal’s serial port parameters to match your host computer’s or serial device’s settings. Once they match, you can communicate through the terminal’s serial port.
6. Press to save the changes and exit the Serial Port screen. The Communications Menu appears. 7. Repeat Steps 3 through 6 to configure another serial port.
] 9. Press ] to exit the Configuration Menu. 10. Press to choose Yes and save the new configuration in RAM. Once the 8. Press to exit the Communications Menu. The Configuration Menu appears.
changes are saved, the terminal uses the new configuration.
Save new configuration (in
RAM)?
Yes
No
CANCEL
248XU.059
] to exit the TRAKKER Antares 2400 Menu System. 12. Press to choose Yes and store your changes permanently in flash 11. Press memory.
Store configuration changes in flash memory? (used when rebooting the terminal)
Yes
No
CANCEL
248XU.054
2-33
Page 76
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 13. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. Exiting
TRAKKER Antares 2400 Menu System
OK
CANCEL 248XU.055
14. If you want to configure a T2480 or T2481 with Ethernet, follow the instructions for “Configuring the Ethernet Parameters” in the next section. If you have a T2485 or T2486, follow the instructions for “Configuring RF Communications” later in this chapter.
Configuring the Ethernet Parameters The TRAKKER Antares 2480 and 2481 terminals have an option for an Ethernet (10BaseT) card. With this option, your terminal can communicate to a host or any device on an Ethernet network. You need to configure these network parameters: Network Parameter
Default Value
Network activate
Disabled
Controller IP address (UDP Plus)
0.0.0.0
Host IP address (TCP/IP)
0.0.0.0
Terminal IP address
0.0.0.0
Network port (UDP Plus)
5555
Network port (TCP/IP)
23
You use the TRAKKER Antares 2400 Menu System to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” Note: If the T2480 or T2481 is on a different IP subnetwork from the controller or host, you must also configure the default router and subnet mask.
2-34
Page 77
nugget
39 Installing the Terminal
2
To configure the T2480 or T2481 for an Ethernet network 1. Configure the Model 200 Controller (UDP Plus) or host (TCP/IP). For help with the controller, see the Model 200 Controller System Manual (Part No. 063439).
_ Y
2. Configure the terminal. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.
Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.
CONFIGURATION MENU Symbologies Menu Communications Menu Terminal Menu
⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 248XU.217
Y The 4. Press to choose the Primary Network command. The Primary Network
3. Press to choose the Communications Menu and then press Communications Menu appears. screen appears.
UDP Plus Primary Network
TCP/IP Primary Network
PRIMARY NETWORK
PRIMARY NETWORK
Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
CANCEL
OK
CANCEL 248XU.186
2-35
Page 78
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
`
5. Press to set the Network Activate command to Ethernet. Press move to the next field.
Y to
Enter the Controller IP address for a UDP Plus network. Enter the Host IP address for a TCP/IP network. Enter the Terminal IP address. IP address fields consist of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .
Y
For example, if your terminal IP address is 192.100.100.3, type:
Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
to save the changes and exit the Primary Network screen. 7. For TCP/IP networks, press _ to choose the Advanced Network command and then press The Advanced Network screen appears. 6. Press
UDP Plus Advanced Network ADVANCED NETWORK Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07
TCP/IP Advanced Network ADVANCED NETWORK Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 032 sec
OK
CANCEL
` more 248XU.192
Note: For UDP Plus networks, the Network Port default is 5555, which matches the default value set on the Model 200 Controller. 8. In the Network Port field, type a number from 1 to 65535 and then press . The default value is 23, which enables VT/ANSI Telnet communications. If you are not using Telnet communications, enter the port number used by your application.
Note: If the terminal is on a different IP subnetwork from the Model 200 Controller or host, you must also configure the default router and subnet mask. Choose the Advanced Network command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.”
2-36
Page 79
nugget
39 Installing the Terminal
2
] 10. Press ] to exit the Configuration Menu. 11. Press to choose Yes and save the new configuration in RAM. Once the changes are saved, the terminal uses the new configuration. 12. Press ] to exit the TRAKKER Antares 2400 Menu System. 13. Press to choose Yes and store your changes permanently in flash memory. 14. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. 9. Press to exit the Communications Menu. The Configuration Menu appears.
The T2480 or T2481 will now try to establish communications with the Model 200 Controller or the host.
For terminal emulation applications in a UDP Plus network, you need to configure the host name in the TE Configuration menu to establish communications. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. Once the terminal connects, the login or initial screen for your application appears and the Connect status light remains on. You can begin using the terminal to collect data. Follow the instructions in the section on “Starting the Application and Using the Terminal” later in this chapter.
Configuring RF Communications The TRAKKER Antares 2485 or 2486 terminal can communicate with a host computer in Intermec’s 2.4 GHz RF network either through the Model 200 Controller or directly through the access points. The terminal uses one of these RF network protocol options to communicate with other devices: •
UDP Plus
•
TCP/IP
Each T2485 or T2486 ships with only one of these RF network protocols. In a UDP Plus network, the terminal communicates through the Model 200 Controller to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network. In a TCP/IP network, the terminal communicates through the access point, which is connected to the host on an Ethernet or token ring network.
2-37
Page 80
TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39
Intermec’s 2.4 GHz RF Networks Host TCP/IP Direct Connect
UDP Plus
Ethernet
Access point
T2485/6
Model 200 Controller
T2485/6
T2485/6
Access point
T2485/6
248XU.231
You need to configure these network parameters to begin using RF communications: Network Parameter
Default Value
Network activate
Disabled
Controller IP address (UDP Plus)
0.0.0.0
Host IP address (TCP/IP)
0.0.0.0
Terminal IP address
0.0.0.0
RF domain
0
RF security identification (ID)
None (not set)
Network port (UDP Plus)
5555
Network port (TCP/IP)
23
You use the TRAKKER Antares 2400 Menu System to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” Note: If the T2485 or T2486 is on a different IP subnetwork from the controller or host, you must also configure the default router and subnet mask.
2-38