Page 41

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Drive C is a 750K flash drive on the T248X. You can store up to 32 files on drive C. Applications must be stored on drive C. Drive D is an optional 2MB extended flash memory storage that can be used as a storage drive or a storage space for double-byte fonts. You can store up to 32 files on drive D or store a 2MB double-byte font set. If you configure the flash memory as drive D, use this drive to store large lookup tables and data files. For help configuring the drive, see “Configuring Drives and Memory on the Terminal” in Chapter 3. Note: You can only configure the 2MB flash memory as a drive or to store fonts. You cannot use the space for both. If you configure drive D, you cannot store a font in flash memory. Drive E is a configurable RAM drive (up to 256K). By default, the RAM drive is not configured and the memory is available for programmable (Malloc) memory allocations. You can store up to 32 files on drive E. The contents of the RAM drive are erased when you boot or reset the terminal, or change the backup battery. For help configuring the drive, see “Configuring Drives and Memory on the Terminal” in Chapter 3. Drive G is an optional 2MB or 4MB extended storage drive that is available for a T2480/1 terminal with Ethernet connectivity or a T2485/6 terminal. You can store up to 32 files on drive G. Use this drive to store large lookup tables and data files. Note: On each drive, filenames are customer defined using eight characters with a three-character extension. On the TRAKKER Antares terminals, applications are customer defined. You have 512K total RAM for the application execution space. You can configure up to 256K of the total 512K application execution space as a RAM drive. If the RAM drive is configured, your application execution space is reduced by the amount of the RAM drive. Application execution space

+

Drive E

≤

512K RAM

Note: The remaining RAM is automatically used as the Malloc/free dynamic memory pool. For example, if the application size is 64K and drive E is configured as a 256K RAM drive, you are using 320K of the 512K application execution space. The application uses the remaining 192K of RAM as a Malloc/free dynamic memory pool. The application size is not necessarily the size of the *.BIN file. You can use the compiler map file output to determine the application size.

1-25

Page 42

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Where Do You Go From Here? Now that you understand the features and capabilities of your new TRAKKER Antares terminal, you can use this manual to learn how to perform these tasks:

1-26

Task or Feature

See This Chapter

To learn how to install the terminal and connect it to your network

Chapter 2, “Installing the Terminal”

To learn how to change the terminal’s configuration

Chapter 3, “Configuring the Terminal”

To learn how to use the terminal in your 2.4 GHz RF or wired data collection system and learn about network protocols

Chapter 4, “Operating the Terminal in a Network”

To learn how to download and run custom applications or screen mapping on your programmable terminal

Chapter 5, “Using Custom Applications and Screen Mapping”

Page 43

2 Installing the Terminal

Page 44

This page is a scan with no text; see it in the PDF.

Page 45

nugget

39 Installing the Terminal

2

This chapter explains how to install the TRAKKER Antares 248X terminal in your serial, Ethernet, or RF network. You will also learn how to turn on the terminal and configure the network parameters to start using the terminal.

Preparing to Install the Terminal Make sure you have the necessary equipment to install and connect the T248X to your network. The terminal ships with this equipment: •

T2480, T2481, T2485, or T2486 terminal

•

Antenna (ships only with the T2485 and T2486)

•

Terminal blocks (ships only with the enhanced input/output board option)

•

Power supply

•

North American power cord

Note: A badge scanner may already be installed on the terminal if you ordered this option. In addition, you may need this equipment (not shipped with the T248X) to install the terminal: •

Power cord for terminals used outside of North America

•

Mounting bracket (desk-mount or wall-mount)

•

Input device (badge scanner, wand, laser scanner, CCD scanner)

•

RS-232 or RS-232/422/485 serial communications cables

•

Multi-drop cable

•

Ethernet (10BaseT) cable

•

Wiring for sense inputs, output relays, and external speakers

Before you install the terminal, you should: 1. Choose a location to mount the terminal. 2. Attach the antenna to the T2485 or T2486. 3. Find out about using the desk-mount and wall-mount brackets. Each of these topics are covered in the next sections. You should also make sure you are familiar with the connectors and equipment inside the terminal’s rear enclosure. For help, see “Understanding the Back Panel” in Chapter 1.

2-3

Page 46

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Choosing a Location You can mount the T248X on a horizontal surface, such as a desktop or table-top, or on a vertical surface, such as a wall. The easiest way to mount the T248X is to use one of Intermec’s mounting brackets: •

TRAKKER Antares 248X Desk-Mount Bracket (Part No. 066709)

•

TRAKKER Antares 248X Wall-Mount Bracket (Part No. 066708)

For more information on the brackets, see “Using the Desk-Mount or Wall-Mount Bracket” later in this chapter. Choose a mounting location for the T248X that provides • easy access to the badge scanner or other input devices.

• easy access to the keypad.

• an unobstructed view of the screen.

• clearance for the cables.

• access to a powered AC electrical outlet.

• good communications for the antenna where the antenna is not too close to a metal wall.

To plan for and prepare a mounting location, use the actual size (1:1 scale) mounting templates provided in Appendix D, “Keypad Labels and Terminal Mounting Templates.”

Attaching the Antenna On the T2485 and T2486, the antenna is shipped separately. Remove the antenna from the shipping box and attach the antenna as shown. Choose a location for the terminal where the antenna can be effective. Do not place the terminal where the antenna is too close to a metal wall or it will limit the communications range. You can also use an Intermec-approved accessory antenna to improve RF communications. Note: See your Intermec sales representative for information about and a list of Intermec-approved accessory antennas for the T248X.

2-4

Page 47

nugget

39 Installing the Terminal

2

Caution Make sure all components with antennas are at least 1 foot (0.3 meters) apart when power is applied. Failure to comply could result in equipment damage. Conseil Assurez-vous que la distance entre tous les éléments avec antennes soit d’au moins un pied (0.3 mètres) avant de faire la connexion avec l’alimentation électrique, faute de quoi vous risquez d’endommager votre installation.

Using the Desk-Mount or Wall-Mount Bracket There are two accessories to help you mount the terminal: •

TRAKKER Antares 248X Desk-Mount Bracket (Part No. 066709)

•

TRAKKER Antares 248X Wall-Mount Bracket (Part No. 066708)

To plan for and prepare a mounting location, use the actual size (1:1 scale) mounting templates provided in Appendix D, “Keypad Labels and Terminal Mounting Templates.” To install the desk-mount bracket 1. Connect power and all other devices through the back panel of the terminal. 2. Install the desk-mount bracket and the terminal. For help, see the accessory instruction sheet.

248XU.033

Desk-mount bracket

2-5

Page 48

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To install the wall-mount bracket 1. Install the wall-mount bracket and the terminal. For help, see the accessory instruction sheet. 2. Connect power and all other devices through the back panel of the terminal. To mount the power supply •

The T248X and the power supply are dust and moisture protected to IEC 60529/IP53 only when installed properly in the Intermec deskmount or wall-mount bracket. The brackets use a power supply holder to effectively protect the power supply from dust and moisture. For help, see the accessory instruction sheets.

248XU.034

Wall-mount bracket

Intermec recommends that you use the desk or wall-mount bracket to mount the T248X and protect the power supply. You can use other mounting brackets or enclosures. However, without the Intermec desk or wall-mount bracket, the power supply is intended for indoor use only. Use of any other mounting brackets or enclosures will void the environmental protection ratings of the terminal. Warning Installation of the power supply must be performed strictly in accordance with the procedures contained in the TRAKKER Antares 248X desk and wall-mount bracket instruction sheets. Failure to protect the power supply in areas of high dust and moisture may result in injury or death due to electric shock. Avertissement L’installation de la source d’alimentation doit être exécutée en respectant de façon stricte les procédures décrites dans les feuilles d’instruction du TRAKKER Antares 248X de bureau et monté au mur. L’échec de la protection de la source d’alimentation dans des zones de grande poussière et d’humidité peut entraîner des blessures ou la mort en raison d’un choc électrique.

2-6

Page 49

nugget

39 Installing the Terminal

2

Installing the Terminal and Connecting External Devices The steps to install your T248X depend on the options you purchased and the type of network or devices to which you want to connect the terminal. To install and configure your T248X 1. If you have a wall-mount bracket, install it and install the terminal in the wall-mount bracket. See page 2-5. 2. Connect the power supply and input devices to the T248X. See page 2-8. 3. Connect the T248X to serial devices or networks. See page 2-10. 4. Connect the T248X to an existing Intermec CrossBar network. See page 2-11. 5. Connect the T2480 or T2481 directly to an Ethernet network. See page 2-14. 6. Connect sense inputs, output relays, an unattended scanner, or an amplified external speaker to the T248X terminal blocks. See page 2-15. 7. Route all the cables and secure the back panel. See page 2-25. 8. If you have a desk-mount bracket, install it and install the terminal in the desk-mount bracket. See page 2-5. 9. Turn on the terminal and configure it for your serial, multi-drop, Ethernet, or RF network. See page 2-26. These steps are described in detail in the next sections.

2-7

Page 50

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Connecting Power and Input Devices You connect power and input devices through the rear enclosure of the TRAKKER Antares 248X terminal. To connect the power supply and input devices 1. Use a Phillips screwdriver to remove the six screws on the back panel.

Screw (6 places)

248XU.203

Back panel

2. Remove the back panel and place it on a clean surface. 3. Connect the power supply and input devices to the back of the terminal.

2-8

•

Connect the power supply plug to the 12V power supply connector. Next, connect the power cord from the power supply to a powered electrical outlet.

•

Connect the badge scanner 6-pin connector to the badge scanner connector.

•

Connect the Stewart 10-pin connector from the input device to the external scanner connector.