Page 31

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Adjusting the Contrast From the Keypad \

?

esc

Q tab

E

W

S

A

R

T

F

D

.

,

/

U

Y

G

H

-

+ I

J

O

K

P

L Ctrl

Caps

I/O

:

"

Z

X

C

V

B

N

M Fn L

_f

242XU.049

There are eight contrast levels that define the contrast (light or dark) of the characters against the background terminal screen. If the contrast is at the highest level (7), the characters are bright against a bright background. If you press the key or the contrast key sequence, the contrast changes to the lowest contrast level (0) and the characters are dark against a dark background.

h

To change the volume of the audio signals •

Look for the symbol on your keypad. Press the key sequence to change the volume of the terminal’s audio signals. Each time you press the key sequence, it makes the beep and keyclick volume one level louder. Type of Keypad English, IBM 3270, IBM 5250, and VT/ANSI French, German, Italian, Portuguese, and Spanish Oversized Function Numeric

Press the Key(s)

$ 0 h

There are five volume levels including off. If the volume is at the loudest level and you press the key sequence, the beep and keyclick volume are turned off. If you press the key sequence again, the beep and keyclick volume changes to the quietest level.

1-15

Page 32

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Adjusting the Beep Volume From the Keypad \

?

esc

Q

E

W tab

R

S

A

T

U

Y

F

D

.

,

/

G

H

-

+ I

J

O

P

K

L

: Ctrl

Caps

I/O

Z

"

C

X

V

B

N

M Fn L

_f

242XU.047

Using the Function Key Labels Your terminal ships with strips of function key labels. You can use the labels to identify custom function keys. Write the name for each function key on a strip of five labels. Insert the strip into the slot above the function keys. You can create your own pre-printed function key labels. For the exact function key label measurements, see Appendix D, “Keypad Labels and Terminal Mounting Templates.” Note: There are two sizes of function key labels. Use the labels that are slightly larger if you have a T248X with an oversized function numeric keypad. Use the smaller labels for an alphanumeric keypad.

\

?

esc

Q tab

E

W

S

A

R

F

D

.

,

/

T

U

Y

G

H

J

F6

P

L bksp

: Ctrl

Z

"

F7

F1

O

K

Caps

I/O

-

+ I

X

F8

F2

C

V

F4

N

M Fn L

Fn R

_f

_f _ Enter

F10

F9

F3

B

F5

&

*

7

8

$

%

9

4

5

6

!

@

#

1

2

3

<

Ins

Del

0

>

.

248XU.247

1-16

Page 33

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

How to Use the Terminal’s Screen You can use the TRAKKER Antares terminal’s screen to view data, run applications, monitor the terminal’s status, and for many other functions. The terminal’s black and white screen is CGA compatible. You can use these features of the screen: •

Use the status lights to monitor the status of backup battery power, RF and network communications, special keys, and bar code scanning.

•

Choose a different font size, adjust the row spacing, or change the video mode.

•

In an application, use the terminal’s screen as a viewport to see a full-size terminal screen of 25 lines by 80 characters.

Each screen feature is explained in the next sections. Note: If you are using the terminal in a cold environment, the LCD may respond and display information more slowly than in a warm environment.

Using the Status Lights You can use the terminal’s status lights to monitor the status of backup battery power, RF and network communications, special keys, and bar code scanning. The status lights only flash or turn on to indicate the current status. The Power status light is amber and all other lights are green. When you have the terminal turned off (Suspend mode), the status lights are also off.

Power Network Connect Network Transmit Modifier Key Caps Lock Good Read User Defined 248XU.219

1-17

Page 34

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Using the Status Lights Power This status light remains off when you have power to the terminal, a charged backup battery, and the terminal is on. The light blinks when the backup battery has a low power charge or if you try to turn on the terminal with no external power supply connected to the terminal. The Power status light turns off once the backup battery charges. For help, see “Learning About the Power Supply and Backup Battery” later in this chapter. Network Connect This status light tells you if the T2480 or T2481 is connected to your Ethernet network or tells you if the T2485 and T2486 is connected via RF communications to your 2.4 GHz RF network. The Network Connect status light may be turned off, blinking, or turned on. T2480/1: Ethernet & TCP/IP Ethernet & UDP Plus T2485/6: TCP/IP UDP Plus

Status Light Off

Status Light Blinks

Status Light On

Not connected to the Ethernet network.

Not used.

Connected to the Ethernet network.

Not connected to the Ethernet network.

Not connected to the Model 200 Controller.

Connected to the controller.

Not connected to an access point.

Not used.

Connected to an access point.

Not connected to an access point.

Not connected to the Model 200 Controller.

Connected to an access point and the controller.

When the Network Connect status light is turned off, you are either not connected to the network or the terminal is not configured. Make sure the Network Activate command is enabled and that the terminal is configured correctly for your network. If your T2485/6 is configured correctly, you may be out of range of an access point. In a UDP Plus network, the Network Connect status light is not instantaneously updated but does tell you the communications status the last time data was sent or received from the terminal. For help with network communications, see Chapter 4, “Operating the Terminal in a Network.” Network Transmit This status light turns on when data is buffered in the RF or Ethernet network interface. The data is either waiting to be transmitted to the Model 200 Controller or host, or received data has not been accepted by the application on the T248X. When no data is being buffered in the interface, the Network Transmit status light is off.

1-18

Page 35

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Using the Status Lights (continued) Modifier Key This status light turns on when you press one of the four modifier keys: , , , or . The modifier key is stored in the keypad buffer until you press another key. When you press a second key, the key combination is entered into the terminal and the status light turns off.

to enable the Caps Caps Lock This status light turns on when you press Lock feature and type all alphabetic characters as uppercase letters. When you press to disable Caps Lock, the light turns off.

Note: On a German alphanumeric keypad, press

8.

Good Read This status light turns on when you successfully scan a bar code label with an input device (badge scanner, laser scanner) that is connected to the terminal. The status light turns off after 2 seconds. User Defined This status light is user defined. You can program this status light to turn on and off for any task or error within your application.

Customizing the Font Size and Screen Parameters On each T248X, you can customize the font size, row spacing, and video mode to meet your needs. You can configure these options: Font size Set the font size to 8x8 (8 pixels by 8 pixels), 8x16, or 16x16. The default for the T248X terminals is the 8x16 font size (single-width and doubleheight characters). Note: The 8x8 font size is not available on the T2480 and T2485. Row spacing Set the row spacing to a value from 0 to 8 on the T2481 and T2486 terminals. Row spacing lets you define the amount of additional space (scan lines) between the lines. The number of scan lines is two times the value you set for the row spacing. A scan line is a row of pixels. A value of 8 adds 16 blank scan lines to increase the space between lines. For the T2481 and T2486, the default is 0. Note: The Row Spacing command is not available on the T2480 and T2485. Video mode Set the Video mode to original, normal, or reverse. The default is original and displays black characters on a white background. Original is the Video mode set at the Intermec factory. Normal mode displays black characters on a white background. Reverse mode displays white characters on a black background.

1-19

Page 36

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 Depending on the T248X model you have, there are two default screen sizes: •

4 lines by 40 characters for the T2480 and T2485

•

12 lines by 40 characters for the T2481 and T2486

Use this next table to determine the font size that meets your needs. Model

Font Size

Row Spacing

Characters Displayed

T2480 and T2485

8x16 (default)

7 (default)

40 characters by 4 lines

16x16

7 (default)

20 characters by 4 lines

8x8

0 8

40 characters by 25 lines 40 characters by 9 lines

8x16 (default)

0 (default) 8

40 characters by 12 lines 40 characters by 6 lines

16x16

0 8

20 characters, 12 lines 20 characters by 6 lines

T2481 and T2486

Note: The row spacing cannot be changed on the T2480 and T2485.

Using the Screen As a Viewport The TRAKKER Antares 248X terminal screen shows 4 lines by 40 characters up to a maximum of 25 lines by 80 characters of data at one time (depending on the model and configuration). In terminal emulation (TE) or custom applications, the terminal’s screen may show only part of each 25 line by 80 character screen that appears on a full-size terminal. If your application supports viewporting, you can use the terminal screen as a viewport to move around and see the entire 25 x 80 screen. The viewport lets you view screens and enter data by showing the part of the screen you are using. When you are using one of the Intermec TE applications, the viewport automatically moves to the cursor when there is data entry from the host computer or the terminal. You can configure the viewport for your TE applications to • follow the cursor.

• center the viewport around the cursor.

For help on configuring the TE viewport options, see the TRAKKER Antares Terminal Emulation User’s Guide.

1-20

Page 37

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Understanding the Terminal’s Audio Signals The TRAKKER Antares 248X terminal has an internal speaker to sound audio signals and beep sequences as you use the terminal. For example, you hear a low beep tone each time you enter or scan a valid command. You can change the audio volume to meet the needs of your working environment. For example, use a quiet beep in a library or a loud beep in a manufacturing plant. There are three ways to change the audio volume:

$ h

0

•

Use the keypad (press , , or depending on your keypad). For help, see “Adjusting the Contrast and Beep Volume From the Keypad” earlier in this chapter.

•

Use the Beep Volume command.

•

Use the TRAKKER Antares 2400 Menu System. For help, see Chapter 3, “Configuring the Terminal.”

Note: If the Beep Volume is turned off, you will not hear any audio signals including the keyclick. If you have a T248X with an enhanced input/output board, you can attach an amplified external speaker to amplify the terminal’s audio signals. For help, see Chapter 2, “Installing the Terminal.” The next table explains the purpose of each beep sequence you may hear. Beep Sequence

Description

Low beep

You entered a valid command or the data you entered was stored.

High beep

You entered valid data, the terminal decoded a label, or the terminal decoded the last row of a two-dimensional symbology.

Three low beeps

You entered or scanned an invalid command or data.

Four low beeps

When you boot the terminal, you hear four low beeps once the power-on self test (POST) has executed successfully.

Low beep, high beep, low beep, high beep

You hear this beep sequence when POST failed and did not execute successfully.

Click

When you press a key, the terminal sounds a click. You can disable the keyclick. The terminal also clicks while you are scanning a two-dimensional symbology (Code 16K or Code 49) bar code label.

Low beep (every 15 seconds)

The main battery pack is low. You need to replace or recharge the battery pack. For help, see the next section, “Learning About the Power Supply and Backup Battery.”

1-21

Page 38

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Learning About the Power Supply and Backup Battery The TRAKKER Antares 248X terminal operates using an external power supply. It has a rechargeable NiCd (Nickel-Cadmium) backup battery that is designed to back up all memory and the real-time clock while AC power is not supplied. You must have a power supply connected to operate the terminal. An Intermec power supply and North American power cord ship with the terminal. If you are using the terminal outside North America, you need to purchase the appropriate power cord for your local power supply.

Backup Battery The backup battery is a rechargeable NiCd battery that is designed to back up all memory and the real-time clock while AC power is not supplied. The backup battery provides protection for power surges, sags, spikes, and dropouts. Here are the features of the backup battery: •

During a power loss, the terminal uses backup battery power to continue operating for 3 seconds. If power is still not restored, the terminal saves all data and turns off. However, if the backup battery charge is low, the terminal cannot protect the data against a power loss and will turn off immediately.

•

The backup battery is rechargeable. The power supply provides the power to charge the backup battery when required with the terminal turned on or off. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low.

•

The backup battery will last for a minimum of three years before its capacity is reduced. Battery life depends on the age of the backup battery, your usage, and RF duty cycle factors. If you are using the terminal in extreme environments (very hot or very cold), battery life will be reduced and you may need to replace the backup battery more often.

•

The backup battery will provide backup battery power for a minimum of 2 weeks with a fully-charged backup battery pack installed and no AC power. If you plan to store the terminal for a long period of time, save any data stored in RAM to another drive on the terminal. If the backup battery is still providing power when you reconnect the power supply and turn the terminal on, the terminal resumes exactly where it was when you turned it off, or restarts your application. Note: If the Resume Execution command is allowed, the terminal will resume the application when you turn on the terminal. Otherwise, the terminal boots and the application restarts.

1-22

Page 39

nugget

39 Introducing the TRAKKER Antares 248X Terminal

1

Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but may not be fully charged when you initially unpack your terminal. You need to fully charge the backup battery after you first install it. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low. If an external power supply is not connected or powered, the backup battery will not charge. If the Power status light blinks, the backup battery charge is low. You can operate the terminal while the backup battery is charging. There are two ways to find out if the backup battery charge is low: •

The Power status light is blinking on the left side of the screen.

•

Check the status of the backup battery using the Backup Battery/PIC Status diagnostic.

Note: The backup battery charger operates between 32°F and 104°F (0°C and 40°C). If you are continuously using the terminal in an environment that is outside this temperature range, the backup battery will not charge. You may need to protect the terminal and create an environment that is within the charging temperature range for a few hours every week to keep the backup battery charged. To charge the backup battery 1. Make sure the power supply is connected to the terminal and a powered electrical outlet. 2. Let the power supply charge the backup battery for 24 hours to fully charge the backup battery.

Recognizing a Low or Discharged Backup Battery If you see the Power status light blinking, the terminal is indicating that the backup battery power is low. Make sure the external power supply is connected to the terminal and a powered electrical outlet. The backup battery is fully charged within 24 hours. If the Power status light continues to blink after 24 hours and the power supply is attached, the backup battery may be bad. Use the Battery/PIC Status diagnostic in the TRAKKER Antares 2400 Menu System to check the status of the backup battery. The Battery/PIC Monitor diagnostic screen displays the current status (good or bad), the voltage, the temperature, and the charging status of the backup battery.

1-23

Page 40

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 If the backup battery status is bad or the backup battery will no longer hold a charge (Power status light is always blinking), you may need to replace the backup battery. You need to backup all your data stored in RAM. Any data stored in flash memory or on the SRAM drive will be saved. For help, contact your local Intermec Service Representative. Note: The NiCd backup battery is NOT user-serviceable. You must return the TRAKKER Antares 248X terminal to Intermec to replace the backup battery. Caution When you replace the backup battery, all data stored in RAM is lost. Conseil Lors du remplacement de la batterie de secours, toutes les données stockées dans la mémoire vive (RAM) sont perdues. Note: If you use the terminal in a very cold or very hot temperature environment, battery life will be reduced or the backup battery may not charge. For more information, see “Backup Battery” earlier in this chapter.

Defining the Terminal’s Memory and Drives The TRAKKER Antares 248X terminals come with the following memory and drives:

750K flash drive

Drive C Optional 2MB flash memory 256K configurable RAM drive

Drive D

Optional 2MB or 4MB extended storage drive

Drive E

Drive G 248XU.180

1-24