TRAKKER Antares 248X Stationary Terminal User's Manual, pages 51 to 60

Pages 51 to 60 of 255

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 2480, Intermec 2481 and Intermec 2485

Page 51

nugget

39 Installing the Terminal

2

Connecting the Power Supply and Input Devices External scanner connector

Badge scanner connector

12V power supply connector

12V power supply plug Cable restraint 248XU.233

Cable restraint bar To power Scissors supply seal

4. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the power supply cable under the cable restraint. Tighten the screw to secure the cable. 5. Route all the cables under the cable restraint bar and through the scissors seal. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

2-9

Page 52

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Connecting to Serial Devices and Networks You use the terminal’s serial ports to transfer data between the terminal and a serial device. Every T248X has one serial port (COM1) that supports RS-232 communications. You can use COM1 to connect to a serial device, such as a printer, scale, or PC. The terminal has an option for an enhanced input/output board that provides two additional serial ports. COM2 supports RS-232/422/485 communications. You can use COM2 to connect to a serial device, a wired network, or an Intermec CrossBar network. COM4 supports RS-232 communications. You need the adapter cable accessory (Part No. 067185) to use COM4. To connect the COM ports 1. Connect the 9-pin RS-232 connector from a serial device to the COM1 connector on the back of the terminal.

COM4

COM1

248XU.241

COM2

To device

2. Connect the 25-pin serial or multi-drop connector from a serial device or network to the COM2 connector on the back of the terminal. 3. Connect the 9-pin RS-232 connector from a serial device to the COM4 adapter cable on the back of the terminal. 4. Route the cables under the cable restraint bar and through the scissors seal. 5. Plug the other end of the serial or multi-drop cable into the serial device or network. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

2-10

Page 53

nugget

39 Installing the Terminal

2

Connecting to an Intermec CrossBar Network If you have a T248X with an enhanced input/output board, you have a second serial port (COM2) that supports RS-232/422/485 communications. With COM2, you can install the T248X in an existing CrossBar network. The T248X can communicate with a 9154 or 9161 controller using Multi-Drop protocol. One main difference between the T248X and the 9560 stationary terminal is the type of program or application you can run on the terminal. The T248X can run a C/C++ application while the 9560 terminal runs IRL programs. You need to prepare your IRL data collection program for the T248X by converting it to a Microsoft C/C++ application. There are two options for converting an IRL program: •

Use an IRL-to-C conversion program. For help, contact your local Intermec service representative.

•

Write a new C/C++ application. You can use either the TRAKKER Antares Programmer’s Software Kit (PSK) (Part No. 065332) with Microsoft Visual C/C++ version 1.5X (Part No. 590224) or EZBuilder (Part No. 066381). For help, see “Creating Applications for the Terminal” in Chapter 5.

The application needs to send and receive data through COM2. Once your application is converted, you can download the application to the T248X and begin using it in your CrossBar network. Follow the next instructions to install and configure the terminal for a CrossBar network. Host

9154/9161

T248X

Printer

T248X

9560

248XU.039

9560

Printer

2-11

Page 54

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39 To install the T248X in an existing CrossBar network 1. Connect the 25-pin multi-drop connector from your 9154 or 9161 controller to the COM2 connector on the back of the terminal.

COM4

COM1

248XU.241

COM2

To device

2. To download applications to the T248X, you need to connect the terminal to a PC using COM1 or COM4. Connect the 9-pin RS-232 connector from the PC to the COM1 connector or the COM4 adapter cable on the back of the terminal. 3. Route the cables under the cable restraint bar and through the scissors seal. 4. Plug the other end of the multi-drop cable into the 9154 or 9161 controller. 5. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter. Next, continue with Step 6. 6. Turn on the terminal and configure the serial ports. For help, see “Configuring the Serial Port Parameters” later in this chapter.

2-12

•

Configure COM1 or COM4 serial port parameters to match your PC serial port.

•

Configure the COM2 serial port parameters. You need to set Multi-Drop protocol, the baud rate, and the multi-drop address that you assigned for the T248X.

Page 55

nugget

39 Installing the Terminal

2

7. Use the FileCopy utility that ships with the PSK and EZBuilder to download your C/C++ application (converted from IRL) from a PC to the T248X. For help, see Chapter 5, “Using Custom Applications and Screen Mapping.” 8. Use the System Menu in the TRAKKER Antares 2400 Menu System to load and run an application. For help, see Chapter 5, “Using Custom Applications and Screen Mapping.” Once the T248X is installed, configured, and loaded with your C/C++ application, you can begin using the terminal in your CrossBar network. The T248X will run the C/C++ application and send data to the 9154 or 9161 controller. If you have existing terminals like the 9560 or 9512, these terminals will run the equivalent IRL program and send data to the controller. Note: You can use COM1 or COM4 to connect to another RS-232 serial device once you have downloaded the application.

2-13

Page 56

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Connecting Directly to an Ethernet Network The TRAKKER Antares 2480 and 2481 terminals have an option for an Ethernet (10BaseT) card. With this option, your terminal can communicate to a host or any device on an Ethernet network. To connect to an Ethernet network 1. Configure your host computer and network. Assign an IP address for the T2480 or T2481. 2. Connect the Ethernet jack to the Ethernet connector on the back of the terminal.

Ethernet connector

248XU.245

To Ethernet network

3. Use a Phillips screwdriver to loosen one of the screws on the cable restraint. Route the Ethernet cable under the cable restraint. Tighten the screw to secure the cable. 4. Route the cable under the cable restraint bar and through the scissors seal. 5. Plug the other end of the Ethernet cable into an Ethernet jack on your network. 6. To install other devices, leave the back panel off and continue with the next instructions in this chapter. If you are not installing any other devices, continue with the instructions for “Routing Cables and Securing the Back Panel” later in this chapter.

2-14

Page 57

nugget

39 Installing the Terminal

2

Connecting External Devices to the Terminal Blocks If you have a T248X with an enhanced input/output board, your terminal shipped with two terminal blocks. You use the terminal blocks to connect • sense inputs (four) to monitor events, such as the opening of a door.

• output relays (four) to actuate external devices, such as a door lock.

• external speaker to amplify the terminal’s audio signals.

You need to provide the wiring and electrical equipment to connect the terminal blocks to external devices. It is much easier to connect all your wiring to the terminal blocks before attaching them to the terminal block connectors on the back of the terminal. The J12 and J13 terminal block connectors are located on the input/output board on the back of the terminal. Each relay on the terminal blocks is rated for 28V (AC or DC) maximum and 1A maximum. The next illustration and table shows the assignments for each block.

J13

J12

1 2 3 4 5 6 7 8 9 101112 1 2 3 4 5 6 7 8 9 101112

J12 Position

Type

Description

1 2 3

Output relay 1 Output relay 1 Output relay 1

Normally open contact Common Normally closed contact

4 5 6

Output relay 2 Output relay 2 Output relay 2

Normally open contact Common Normally closed contact

7 8 9

Output relay 3 Output relay 3 Output relay 3

Normally open contact Common Normally closed contact

2-15

Page 58

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Terminal Block Definitions (continued) J12 Position

Type

Description

10 11 12

Output relay 4 Output relay 4 Output relay 4

Normally open contact Common Normally closed contact

J13 Position

Type

Description

1 2

Sense input 1 Sense input 1

Optically isolated input A Optically isolated input B

3 4

Sense input 2 Sense input 2

Optically isolated input A Optically isolated input B

5 6

Sense input 3 Sense input 3

Optically isolated input A Optically isolated input B

7 8

Sense input 4 Sense input 4

Optically isolated input A Optically isolated input B

9 10

Reserved Reserved

Reserved Reserved

11 12

External speaker External speaker

Speaker output Speaker ground

The next sections explain how to connect and use the terminal blocks.

Activating External Devices With the Output Relays The T248X has four output relays to actuate external devices, such as a door lock or a turnstile lock. You need to supply the wiring and electrical equipment. Each relay contact is rated for 28V (AC or DC) maximum and 1A maximum. You control the relays with an application that uses the IM_GET_RELAY and the IM_SET_RELAY functions in the TRAKKER Antares Programmer’s Software Kit. If you remove power to the T248X, the relays turn off. The relays remain off until the T248X receives a command from the application. For help, see the TRAKKER Antares Programmer’s Software Kit Reference Manual. The output relays are grouped in sets of three. There are three positions for each output relay on the J12 terminal block. You connect the external device to the appropriate positions depending on the type of default contact state you want to set for the device as explained next.

2-16

Page 59

nugget

39 Installing the Terminal

2

To connect an output relay 1. Use a straight-slot screwdriver to loosen the screws on a set of three output relay positions on the J12 terminal block. For example, if you are connecting a single external device, you would loosen the screws for positions 1 and 2 or positions 1 and 3 on the J12 terminal block.

248XU.043

Note: If the terminal blocks are connected to the I/O board, you may need to remove them to connect the wires. For help, see “Removing the Terminal Blocks From the Input/Output Board” later in this section. 2. Insert the wires for the external device into the appropriate positions. a. If the device requires a normally open contact, connect the wires to positions 1 and 2, 4 and 5, 7 and 8, or 10 and 11 on the J12 terminal block. b. If the device requires a normally closed contact, connect the wires to positions 2 and 3, 5 and 6, 8 and 9, or 11 and 12 on the J12 terminal block. 3. Use a straight-slot screwdriver to tighten the screws and connect the wires.

2-17

Page 60

TRAKKER Antares 248X Stationary Terminal User’s Manual nugget 39

Sample Output Relay Application

Relay output

J12 terminal block 1

2 3 4 5 6

T248X 7 8 9 10 11 12 External device

Electric door opener Secondary circuit 248XU.044

4. Position the terminal block above the J12 terminal block connector on the I/O board. Gently push the terminal block on to the connector until it snaps in place. Note: Do not attach the J13 terminal block if you still need to connect the sense inputs or an external speaker.

248XU.158

2-18