The text of a manual · part 5 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 41 to 50
Pages 41 to 50 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 41
nugget
39 Installing the Terminal
2
Turning On the Terminal for the First Time After the power supply is connected and you have installed the terminal, you are ready to turn on the terminal. To turn on the terminal
•
W
Press the On/Off ( ) button on the terminal. The terminal runs POST (power-on self-test), displays the version number, and then displays the date and time. Note: If the backup battery charge is low and the terminal fails POST, a POST results screen appears and the terminal shuts off. Contact your local service representative before using the terminal.
0
246
On/Off button
246XU.020
2-13
Page 42
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but may not be fully charged. You need to fully charge the backup battery after you install the terminal. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low. You can operate the terminal while the backup battery is charging. To charge the backup battery
1. Make sure the power supply is connected to the terminal and a powered electrical outlet. 2. Let the power supply charge the backup battery for 24 hours to fully charge the backup battery. Note: For more information about the backup battery, see “Learning About the Power Supply and Backup Battery” in Chapter 1.
Configuring the Terminal to Communicate in Your Network You need to configure the 246X terminal to communicate with serial or Ethernet devices in your network. The parameters you configure depend on the type of network or devices to which you want to connect the terminal. Here are the parameters you need to set: •
Time and Date
•
Serial port (COM1, COM2)
•
Ethernet (2461 only)
The next sections list the parameters you need to configure and explain how to use bar code labels to configure the terminal.
Setting the Time and Date You need to set the time and date on the terminal. You use bar code labels to set the time and date. To set the time and date
1. Scan this bar code: Enter Accumulate Mode / Set Time and Date
*+/$+DB* *+/$+DB*
2-14
Page 43
nugget
39 Installing the Terminal
2
2. Scan a numeric value for each digit from these bar codes. Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss
00-99 01-12 01-31 00-23 00-59 00-59
Year Month of the year Day of the month Hour Minutes Seconds
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. If you want to configure a serial port, continue with the next section, “Configuring the Serial Port Parameters.” If you want to configure a 2461, follow the instructions for “Configuring the Ethernet Parameters” later in this chapter.
2-15
Page 44
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Configuring the Serial Port Parameters You must first select the communications protocol for each COM port. Depending on the protocol, you need to set some or all of these serial port parameters to have the terminal communicate with a host computer or serial device in a wired network: Serial Port Parameter
Default Value
Baud rate
19200
Commands via serial port
Enabled without TMF
Data bits
7
EOM (End of Message)
\x03 (hexadecimal ASCII value for ETX)
Flow control
None
Handshake
Disabled
LRC
Disabled
Parity
Even
Poll (Polling)
Disabled
Protocol
Configurable
SOM (Start of Message)
\x02 (hexadecimal ASCII value for STX)
Stop bits
1
Timeout delay
10 seconds
The values you set for the terminal’s serial port must match the values set for the host’s (or other device’s) serial port. In a CrossBar network, you also need to configure your 9154 or 9161 controller to add the new multi-drop 2460 device. For help, see your controller user’s manual. You set the serial port parameters by scanning bar codes. For help, see Chapter 8, “Configuration Command Reference.”
2-16
Page 45
nugget
39 Installing the Terminal
2
Configuring the Ethernet Parameters The 2461 terminals contain an Ethernet card. With this option, your terminal can communicate to a host or any device on an Ethernet network. You need to configure these network parameters: Network Parameter
Default Value
Network activate
Disabled
Controller IP address (UDP Plus)
0.0.0.0
Host IP address (TCP/IP)
0.0.0.0
Terminal IP address
0.0.0.0
Network port (UDP Plus)
5555
Network port (TCP/IP)
23
You scan bar code labels to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” For more information on scanning the bar codes, see Chapter 8, “Configuration Command Reference.” Note: If the 2461 is on a different IP subnetwork from the DCS 300 or host, you must also configure the default router and subnet mask. To configure the T2461 for an Ethernet network
1. Configure the DCS 300 (UDP Plus) or host (TCP/IP). For help with the server, see the DCS 300 System Manual (Part No. 067296). 2. Configure the terminal. Scan the appropriate bar codes from Chapter 8, “Configuration Command Reference.” You will find a table listing the page numbers of all of the Ethernet network communications that you need to configure on page 8-4. The 2461 will now try to establish communications with the DCS 300 or the host. Once the terminal connects, the login or initial screen for your application appears and the Network Connect status light remains on. You can begin using the terminal to collect data.
2-17
Page 46
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Starting the Application and Using the Terminal Your 246X terminal ships with these applications already loaded: •
Sample application (APPTSK.BIN)
•
9560 emulation application (EM9560.BIN)
To start the application and use the terminal
•
W
Press to turn on the terminal. The login or initial screen for your application appears. Sample Application
1998/01/01
9560 Emulation Application
12:00:00
246XU.014
For help on downloading custom applications, see Chapter 5, “Programming the Terminal.” The 9560 application emulates a subset of the functionality available on the 95XX terminals. You can use the application to scan, enter, and display data. For help using the default application or the 9560 emulation application, see Appendix C, “Using the Default Applications.”
Turning the Terminal On and Off
W W
The button on the front of the terminal acts as a Suspend/Resume key. When you press to turn off the terminal, the terminal does not actually shut off, but goes into a Suspend mode. This mode is referred to as “off” in the rest of this manual. In Suspend mode, the terminal continues to power all memory and turns off the power to most of the hardware.
W
When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off, or the terminal boots and restarts your application. Resume is controlled through a parameter or command called Resume Execution. By default, the terminal resumes your application. For help, see “Resume Execution” in Chapter 8.
W
W
W
You can configure the terminal to disable the button. When the button is disabled, you cannot turn off the terminal. By default, the key is enabled so that you can turn the terminal on and off. For help, see “Suspend/Resume Control” in Chapter 8.
2-18
Page 47
3 Configuring the Terminal
Page 48
blank page
Page 49
nugget
39 Configuring the Terminal
3
This chapter explains how to configure the terminal, discusses the terminal’s configuration parameters, and tells you how to restore the default configuration.
How to Configure the Terminal You can configure the TRAKKER Antares 246X terminal by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This method is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual, or you can create your own bar code labels. You can also configure the terminal from a remote device. For example, you can configure the 2461 from another device on the Ethernet network. Or, you can use the DCS 300 or an application from the host to configure the 2461. You can configure any 246X terminal by sending commands from an application through the serial port. For help, see Chapter 4, “Operating the Terminal in a Network.”
Learning About Configuration Parameters You can customize many operating characteristics of the 246X terminals, such as the volume of its status beeps and the bar code symbologies it decodes. These characteristics are controlled by configuration parameters. The values you set for the configuration parameters determine how the terminal operates. By customizing the terminal’s configuration, you can set up the terminal to operate easily and efficiently within your data collection system. Note: To learn the purpose and syntax of each configuration parameter or command, see Chapter 8, “Configuration Command Reference.” The configuration parameters can be organized into three groups, which are discussed in the next sections: bar code symbologies, communications, and general operation. When you configure the terminal, you are performing one or more of these tasks: •
Choosing the Symbologies the Terminal Decodes
•
Specifying How the Terminal Will Communicate
•
Controlling How the Terminal Will Operate
3-3
Page 50
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Choosing the Symbologies the Terminal Decodes This list contains all the bar code symbologies the terminal can decode: •
Codabar
•
Code 49
•
Code 11
•
Code 93
•
Code 128
•
Interleaved 2 of 5 (I 2 of 5)
•
Code 16K
•
MSI
•
Code 2 of 5
•
Plessey
•
Code 39
•
UPC/EAN
When the terminal ships, only these three symbologies are enabled: •
Code 39
•
Code 128
•
UPC/EAN
If you are using one of the other symbologies to encode your bar code labels, you need to configure the terminal and enable the symbology. To quickly enable symbologies, see “Scanning Bar Codes to Enable Symbologies” later in this chapter. To ensure that the terminal can operate quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. When you enable each bar code symbology, you may need to set a check digit, the length of the bar code label, or other options. For help, see the bar code symbology in Chapter 8, “Configuration Command Reference.”
Specifying How the Terminal Will Communicate The 246X terminals use serial communications to send data to and from another serial device. With the Ethernet option, the 2461 can communicate to a host or device on an Ethernet network. To learn how to configure the terminal to fit into your wired or Ethernet network, see Chapter 4, “Operating the Terminal in a Network.”
3-4