Page 51

nugget

39 Configuring the Terminal

3

Controlling How the Terminal Will Operate The operating parameters let you adjust the way the terminal operates. By customizing the operating parameters, you can • set the terminal to automatically shut off after a specified length of time.

• set the terminal to resume applications or restart applications.

• modify bar code data by appending the time.

• modify bar code data by using a preamble and postamble.

• enable or disable specific reader commands.

• configure a RAM drive.

• change the volume of the audio signals (beeper and keypad clicker).

• enable or disable the keypad clicker and keypad caps lock.

• customize the way the scanner connected to the 246X operates by selecting scan ahead data buffering, type of scanner device, decode security level, scanner timeout value, and trigger modes.

Configuring the Terminal by Scanning Bar Codes You can configure the terminal by scanning bar code labels listed in this manual or by creating your own Code 39 or Code 93 bar code labels. For help, see Chapter 8, “Configuration Command Reference.” For example, you can use the Beep Volume configuration command to adjust the volume of the terminal’s audio signals. You can scan this bar code label to set the beep volume to a quiet audio level: Set Beep Volume to Quiet

*$+BV1* *$+BV1*

3-5

Page 52

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

You can create bar code labels that contain more than one configuration command. For example, you can create one bar code label to configure the terminal for: •

One-Shot Scanner mode (SB0)

•

Scanner Redundancy set to high (SR2)

•

Beep Volume set to very loud (BV4)

•

Disable Keypad Clicker (KC0)

One-Shot Scanner Mode, Set Scanner Redundancy to High, Set Beep Volume to Very Loud, Disable Keypad Clicker

*$+SB0SR2BV4KC0* *$+SB0SR2BV4KC0*

To configure these same four configuration commands, you can scan four separate bar code labels. When you create a bar code label to set several configuration commands, follow these rules: •

The bar code label must be printed using Code 39 or Code 93 symbology.

•

The bar code label must include the start and stop character. Most bar code printing utilities automatically include the start and stop character.

•

The bar code label must start with $+ (Change Configuration command).

•

Each configuration command must include the command syntax and the value for the command. For example, BV is the command syntax for Beep Volume and the value 4 sets the beep volume to very loud.

•

If you set one configuration command to a string of ASCII characters and another configuration command follows, you must enclose the value in quotes. If you do not include the quotation marks, the terminal will interpret everything after the first command as data and will not find the second configuration command. For example, to set the preamble to BV, use $+ADBV (no quotes are needed). To set the preamble to BV and turn off the beep volume, use $+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear the preamble and postamble from a single label, use $+AD""AE. Note: To scan a Code 39 bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” in Chapter 8.

•

3-6

To include quotation marks when you set a value, the entire value must be enclosed in quotation marks. Type two sets of quotation marks ("") to include one quotation mark as the value for a command. For example, to set the preamble to ABC"D, use $+AD"ABC""D".

Page 53

nugget

39 Configuring the Terminal

3

When you scan bar code labels, you change the terminal’s current runtime configuration. The changes are not saved in the terminal’s flash memory. To save the changes in flash memory, scan this bar code label: Save Configuration in Flash Memory

*.+1* *.+1*

Scanning Bar Codes to Enable Symbologies The TRAKKER Antares 246X terminals can decode several different types of bar code symbologies. Each symbology, such as Code 39, uses a different scheme for encoding data as bar code. You must configure the terminal to decode the bar code symbology used in your bar code labels. Only enable the bar code symbologies that you need to scan. For more information about each symbology and the configuration options, see Chapter 8, “Configuration Command Reference.” The terminal can decode the bar code symbologies shown in the next table. You can scan the bar code labels in the table to enable a symbology. Note: Only Code 39, Code 128, and UPC/EAN symbologies are enabled when you unpack the terminal.

Bar Code Symbology

Enabled?

To Enable the Symbology

Codabar

No

Enable Standard Codabar, ABCD Start/Stop Code

*$+CD21* *$+CD21* Code 11

No

Enable Code 11 With Two Check Digits

*$+CG2* *$+CG2* Code 16K

No

Enable Standard Code 16K

*$+CP1* *$+CP1* Code 2 of 5

No

Enable Code 2 of 5, 3 Bar Start/Stop, Label Length of 1

*$+CC001* *$+CC001*

3-7

Page 54

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Bar Code Symbology Table (continued)

Bar Code Symbology

Enabled?

To Enable the Symbology

Interleaved 2 of 5 (I 2 of 5)

No

Enable I 2 of 5, Variable Length With a Check Digit

*$+CA99* *$+CA99*

Code 39

YES

Enable Code 39 Full ASCII With No Check Digit

*$+CB111* *$+CB111* Code 49

No

Enable Code 49

*$+CJ1* *$+CJ1* Code 93

No

Enable Code 93

*$+CF1* *$+CF1* Code 128

YES

Enable Standard Code 128

*$+CH1* *$+CH1* MSI

No

Enable MSI Without Check Digits

*$+CN10* *$+CN10* Plessey

No

Enable Plessey With Reverse Start Code

*$+CI10* *$+CI10* UPC/EAN

YES

Enable UPC-A/EAN-13, UPC-E, EAN-8

*$+CE1111111* *$+CE1111111*

Note: You can enable either Code 2 of 5 or Interleaved 2 of 5. If you enable I 2 of 5, Code 2 of 5 is automatically disabled and vice versa.

3-8

Page 55

nugget

39 Configuring the Terminal

3

Saving Configuration Changes in Flash Memory The 246X terminals use two copies of the configuration:

Runtime or RAM configuration This configuration is the current or active set of parameters and options enabled on the terminal. The configuration is stored in RAM and will be lost if you boot or reset the terminal. Boot or flash configuration This configuration is the set of parameters and options last saved in flash memory. The configuration is stored in flash memory and will be saved and used if you boot or reset the terminal. Here are the three ways that you can configure the terminal and how the configuration is updated:

Configure the Terminal

Runtime or RAM Configuration Updated?

Boot or Flash Configuration Updated?

Scanning bar code labels

Yes

No

From a host application through the serial port

Yes

No

2461 terminal from the network (DCS 300 or host)

Yes

No

If you configure the terminal by scanning bar code labels, through the serial port or from the network, you may want to save the changes in flash memory by scanning or sending the Save Configuration in Flash Memory reader command.

To save configuration changes using the reader command •

Scan this bar code label: Save Configuration in Flash Memory

*.+1* *.+1*

Or, send the command .+1 as the last command from the DCS 300 or host application. For help, see Chapter 4, “Operating the Terminal in a Network.”

3-9

Page 56

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Restoring the Terminal’s Default Configuration When you configure the 246X terminal according to the instructions presented in this chapter, the parameters remain in effect until you reconfigure them. If you configure the terminal but do not save your changes in flash memory, the parameters will remain in effect until you boot or reset the terminal. The default configuration for the terminal is listed in Appendix A. You can scan the Default Configuration bar code label to return the terminal to its default configuration. Note: If you restore the default configuration, you may need to reset the serial port or Ethernet parameters to communicate with other devices in your network.

To restore the default configuration using the reader command •

Scan this bar code label: Default Configuration

*.+0* *.+0*

Upgrading the Firmware The terminal firmware includes these items: •

Sample application

•

Operating environment, firmware, and drivers

You can upgrade a terminal to use the latest firmware version without making any hardware changes. There are two upgrade kits:

Firmware Upgrade Kit

Part Number

Description

TRAKKER Antares TCP/IP

066814S

Order this kit for terminals that communicate in a TCP/IP direct connect network or a TCP/IP pass-through network.

TRAKKER Antares UDP Plus

067119S

Order this kit for terminals that communicate with a DCS 300 in a UDP Plus network.

For the 2461, order the kit that works with your protocol. For the 2460, order either kit. To order a firmware upgrade kit, contact your local Intermec service representative. Each kit comes with a utility and instructions to upgrade the firmware on the terminal.

3-10

Page 57

nugget

39 Configuring the Terminal

3

Once you upgrade to the new firmware, you can use all the features described in this manual. Each kit comes with the new firmware version, the applications, the firmware upgrade utilities (DOS and Windows), and instructions about upgrading the terminal firmware. You can upgrade the firmware on the 246X terminal from a host computer or PC using serial communications. For help connecting the terminal, see “Connecting to Serial Devices and Networks” in Chapter 2 and “Using Serial Communications on the Terminal” in Chapter 4. Once the terminal is connected, you can upgrade the firmware. Note: On the 2461, you can also upgrade the firmware on one or more terminals using the Firmware Upgrade Utility on the DCS 300. For help, see the DCS 300 System Manual.

To upgrade the firmware with the Windows utility 1. Connect the terminal to your PC. 2. From Program Manager, start the TRAKKER Antares Firmware Installation utility. The Firmware Installation utility screen appears. Click the Help button on the installation utility at anytime to get more information. 3. Choose the COM port, the application (firmware type), and the communications hardware type. 4. Choose OK. 5. Scan this bar code: Boot Terminal

*-.1* *-.1*

Once the upgrade is complete, the terminal boots and runs the default application.

3-11