Page 31

nugget

39 Installing the Terminal

2

This chapter explains how to install the 246X terminal in your serial or Ethernet network. You will also learn how to turn on the terminal and configure the network parameters to start using the terminal.

Preparing to Install the Terminal Make sure you have the necessary equipment to install and connect the 246X terminal to your network: •

Power supply

•

Power cord

•

Input device (badge scanner, wand, laser scanner, CCD scanner)

•

Optional keyboard

•

RS-232 or RS-232/422/485 serial communications cables

•

Multi-Drop cable (2460 only)

•

Ethernet (10BaseT) cable (2461 only)

Installing the Terminal and Connecting External Devices The steps to install your 246X terminal depend on the options that you purchased and the type of network or devices to which you want to connect the terminal. To install and configure your 246X terminal, you need to

• mount the terminal.

• connect the power supply.

• connect input devices.

• connect a keyboard (optional).

• connect the 246X terminal to a serial devices or network.

• connect the 2460 to an existing Intermec CrossBar network.

• connect the 2461 directly to an Ethernet network.

• charge the backup battery.

• turn on the terminal.

• configure the terminal for your serial, CrossBar, or Ethernet network.

These procedures are described in detail in the next sections.

2-3

Page 32

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Mounting the Terminal You can mount the terminal on any horizontal or vertical surface. The sloping front panel of the 246X terminal makes reading the status lights easy at any angle and you can rotate the screen to accommodate any viewing angle. The terminal is designed for use in an indoor environment. Make sure that the location that you select is relatively dust-free, stable, and dry. Note: Make sure that you mount the terminal so that you can easily connect the power supply to the back of the terminal. To mount the 246X terminal

W

1. Select a flat surface. Make sure that you have easy access to the connectors, On/Off ( ) button, status lights, and screen. 2. Use the mounting template in Appendix A to mark the placement of the mounting holes on the mounting surface. 3. Drill two mounting holes in your mounting surface. 4. Place the terminal over the mounting holes and install a screw (not provided) through each mounting hole in the 246X terminal. Mounting screw (2 places)

0

246

246XU.003

2-4

Page 33

nugget

39 Installing the Terminal

2

Connecting the Power Supply You connect power to the terminal using the main power supply. To connect the power supply

1. Connect the power supply to the power connector on the terminal. Connect the power cable from the power supply to a powered electrical outlet.

Power supply

Power connector Power cable

246XU.005

2. To make sure that you keep the power supply cable connected to the terminal, take a loop of the power supply cable and secure it to the strain relief using a tie-wrap.

Strain relief

246XU.006

To power supply

2-5

Page 34

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Connecting Input Devices The 246X terminal supports wands, badge scanners, laser scanners, and CCD scanners. You can use these input devices to collect data with the 246X terminal: •

126X, 127X, and 128X wands

•

1354 and 1355 badge scanners

•

1517, 1518, 1519, and 1545 laser scanners

•

1550A, 1551A, 1550C and 1551C laser scanners

•

1550B laser scanner with software version 1.9 or later

•

1551B laser scanner with software version 1.1 or later

•

1552 cordless laser scanner with 9745 base station

•

1463 CCD scanner

To connect input devices

•

Connect the 10-pin Stewart connector from the input device to the scanner connector on the 246X terminal.

0

246

246XU.022

When you turn on the terminal and scan a bar code, the Good Read status light turns on for 2 seconds if the bar code was scanned successfully. For help on scanning with your input device, see the documentation for the input device.

2-6

Page 35

nugget

39 Installing the Terminal

2

Connecting a Keyboard You can connect a keyboard to the 246X terminal. There are two keyboard accessories available for the terminal: •

Alphanumeric keyboard (Part No. 068662)

•

Numeric keyboard (Part No. 069113)

You can also attach a standard PC-AT keyboard to the terminal. However, you will find that not all of the keys on the keyboard work the same as if the keyboard were attached to your PC. To connect a keyboard

•

Insert the keyboard DIN connector into the keyboard connector on the 246X terminal.

Keyboard connector DIN connector

246XU.008

If you are using the alphanumeric keyboard accessory: •

Intermec recommends that you use the numeric keys that run across the top of the keyboard.

•

Pressing the Num Lock and Caps Lock keys perform the same function. If you press Caps Lock and then press Num Lock, you cancel the function of the Caps Lock key.

2-7

Page 36

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

•

Access the 10-key built-in keypad by pressing the Fn (Function) key followed by the numeric key.

•

The left and right Alt keys are mapped to Function Left and Function Right supported by other TRAKKER Antares products.

If you are using the numeric keyboard accessory: •

Press Num Lock to access the cursor and paging keys.

Connecting to Serial Devices and Networks You use the terminal’s serial ports to transfer data between the terminal and a serial device. Every 246X terminal has one serial port (COM1) that supports RS-232 communications. You can use COM1 to connect to a serial device, such as a printer, a scale, a 9189, or a PC. The 2460 comes with two serial ports: COM1 and COM2. COM2 supports RS-232/422/485 communications. You can use COM2 to connect to a serial device, a wired network, or an Intermec CrossBar network. To connect the 246X terminal to a serial device or network

1. Insert the 9-pin RS-232 connector into the COM1 port on the back of the terminal.

COM2 COM1 RS-232 connector 246XU.016

To serial device

2. Insert the 25-pin serial or multi-drop connector from a serial device or network to the COM2 port on the back of the terminal. For help connecting to a CrossBar network, see the next section, “Connecting to an Intermec CrossBar Network.” 3. Use a small straight-slot screwdriver to tighten the two screws in the each connector. 4. Attach the other end of the RS-232 cable to the serial device or network.

2-8

Page 37

nugget

39 Installing the Terminal

2

Connecting to an Intermec CrossBar Network If you have a 2460, you have a second serial port (COM2) that supports RS-232/422/485 communications. With COM2, you can install the 2460 in an existing CrossBar network. The 2460 can communicate with a 9154 or 9161 controller using Multi-Drop protocol. One main difference between the 2460 and the 9560 stationary terminal is the type of program or application you can run on the terminal. The 2460 can run a C/C++ application while the 9560 terminal runs IRL programs. You need to prepare your IRL data collection program for the 2460 by converting it to a Microsoft C/C++ application. There are two options for converting an IRL program: •

Use an IRL-to-C conversion program. For help, contact your local Intermec service representative.

•

Write a new C/C++ application. You can use either the TRAKKER Antares Programmer’s Software Kit (Part No. 065332) with Microsoft Visual C/C++ version 1.5X (Part No. 590224) or EZBuilder (Part No. 066381). For help, see “Creating Applications for the Terminal” in Chapter 5.

The application needs to send and receive data through COM2. Once your application is converted, you can download the application to the 2460 and begin using it in your CrossBar network. Follow the next instructions to install and configure the terminal for a CrossBar network. Host

9154/9161

T246X

T246X 9560

Printer

246XU.010

9560

Printer

2-9

Page 38

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

Equipment you need to install the 2460 in a CrossBar network

Make sure you have this equipment before you begin: •

One Multi-Drop (or Drop) cable (Part No. 047653) for each 2460 terminal

•

One TRAKKER Antares CrossBar adapter (Part No. 069447) for each 9154 or 9161 controller

To install the TRAKKER Antares CrossBar adapter

1. On the 9154 or 9161 controller, disconnect the Multi-Drop network cable. 2. Connect the Multi-Drop network cable to one end of the TRAKKER Antares CrossBar adapter. 3. Connect the other end of the TRAKKER Antares CrossBar adapter to the 9154 or 9161 controller. To 9154 or 9161 controller port TRAKKER Antares CrossBar adapter

To 2460 or 95XX terminal

Drop cable 246XU.031

Trunk cable

To 2460 or 95XX terminal

Drop cable

Trunk cable

Connect to next drop cable

To install the 2460 in an existing CrossBar network

1. Insert the 25-pin multi-drop connector of the Drop cable (Part No. 047653) into the COM2 port on the back of the terminal. 2. Use a small straight-slot screwdriver to tighten the two screws in the multi-drop connector.

2-10

Page 39

nugget

39 Installing the Terminal

2

3. Attach the 9-pin connectors on the other end of the Drop cable into your multi-drop network.

2460

COM2 RS-232/422/485 connector

Drop cable

Connect to next drop cable

Connect to next drop cable

246XU.017

4. Download an application to the 2460. The procedure you follow depends on the COM port you choose for the download. •

If you use COM1 and RS-232 communications, follow these steps: a. Connect the 9-pin RS-232 cable from the PC to the COM1 connector on the back of the terminal. b. Turn on the 2460. c. Configure the COM1 serial port parameters to match your PC serial port. For help, see “Configuring the Serial Port Parameters” later in this chapter. d. Use the FileCopy utility that ships with the PSK and EZBuilder to download your C/C++ application (converted from IRL) from a PC to the 2460. For help, see Chapter 5, “Programming the Terminal.”

•

If you use COM2 through the CrossBar network, follow these steps: a. Turn on the 2460. b. Configure the COM2 serial port parameters. You need to set Multi-Drop protocol, baud rate, and multi-drop address that you assigned for the 2460. For help, see “Configuring the Serial Port Parameters” later in this chapter. c. Use the “Receive and Convert 7-Bit ASCII Files to 8-Bit Binary Files” command or the “Transmit and Convert 8-Bit Binary Files to 7-Bit ASCII Files” command to download an application through the 9154 or 9161 controller to the 2460. For help, see Chapter 7, “Reader Command Reference.”

2-11

Page 40

TRAKKER Antares 246X Stationary Terminal User’s Manual nugget

39

5. Load and run an application. For help, see “Run Program” in Chapter 7. Once the 2460 is installed, configured, and loaded with your C/C++ application, you can begin using the terminal in your CrossBar network. The 2460 will run the C/C++ application and send data to the 9154 or 9161 controller. If you have existing terminals like the 9560 or 9512, these terminals will run the equivalent IRL program and send data to the controller. Note: You can use COM1 to connect to another RS-232 serial device once you have downloaded the application.

Connecting Directly to an Ethernet Network The 2461 terminals come with an Ethernet (10BaseT) card that allows your terminal to communicate with a host or any device on an Ethernet network. To connect to an Ethernet network

1. Configure your host computer and network. Assign an IP address for the 2461. 2. Connect the Ethernet jack to the Ethernet connector on the back of the terminal.

Ethernet connector 246XU.012

To Ethernet network

3. Plug the other end of the Ethernet cable into an Ethernet connector on your network.

2-12