Page 21
Introducing the 246X Stationary Terminal
This chapter introduces the TRAKKER
1
246X stationary terminals. You will
Antares learn about the terminal connectors and learn how to understand the terminal's status lights, status beeps, power, memory, and drives.
What Are the 246X Stationary Terminals? The TRAKKER Antares 246X stationary terminals (2460 and 2461) are desktop data collection terminals. You can use these programmable terminals to run client/server applications such as work-in-process, time and attendance, or document tracking. You use the 2460 and 2461 terminals to collect and upload data to a host computer via serial or Ethernet communications. You can configure the terminal by scanning bar codes or by downloading configuration commands from your host. Note: The 246X terminals communicate with either the DCS 300 or the Model 200 Controller. The DCS 300 is a data collection server that replaces the Model 200 Controller.
0
246
246XU.001
Models and Options for the 246X Terminals The 246X terminals include these models: The 2460 is a programmable data collection terminal that uses serial ports to transmit data to and receive data from a host or PC. The 2460 has two serial ports, COM1 and COM2. 2460
The 2461 is a programmable data collection terminal that has both a serial port and an Ethernet connector to transmit data and receive data. You can choose either UDP Plus (DCS 300 network) or TCP/IP network protocol. 2461
1-3
Page 22
TRAKKER Antares 246X Stationary Terminal User’s Manual
Standard Features The 246X terminal ships with these standard features: •
512K of RAM reserved for applications
•
2MB flash memory, of which 750K is available as a flash drive for storing user applications and files
•
Scanner connector to attach a wand, laser scanner, or CCD scanner
•
Serial port (COM1) for RS-232 communications between the terminal and host
Options •
Optional 4MB programmable flash memory (the extra 2MB can be configured as drive D)
Accessories for the Terminal You can use these accessories (sold and ordered separately) with the 246X terminals: The main power supply (Part No. 065236) provides 12V to the 246X terminal. The power supply ships with a North American power cable (Part No. 586105). You must purchase power cables for other countries separately. Main Power Supply
Power Cables
The main power supply supports these international power cables:
Country
Intermec Part Number
UK Europe Switzerland China Chile, Italy Denmark
586266 586267 586276 586281 586282 586283
Keyboard
There are two keyboard accessories available for the terminal:
•
Alphanumeric keyboard (Part No. 068662) is a compact QWERTY-style and supports a subset of keys that are available on a standard PC-AT keyboard.
•
Numeric keyboard (Part No. 069113) supports 10-key numeric entry.
You must use this adapter (Part No. 069447) when adding the 2460 terminal to CrossBar network. This adapter connects the 9154 or 9161 to the Multi-Drop cable (Part No. 047653), which connects to the terminal. For help, see “Connecting to an Intermec CrossBar Network” in Chapter 2. TRAKKER Antares CrossBar adapter
1-4
Page 23
Introducing the 246X Stationary Terminal
1
Understanding the Terminal Connectors
2460
5 4
1 3 2
2461
1
4 3
6
2 246XG.002
Each connector on the back panel of the 2460 and 2461 is defined next. 1
Scanner (Stewart 10-pin) connector
The scanner connector lets you connect an input device to the terminal. 2
Keyboard connector
3
12V power supply connector
4
COM1
5
COM2 (2460 only)
The keyboard connector lets you attach the keyboard accessory to the 246X terminal. The terminal operates using an external power supply. You must have a power supply connected to operate the terminal.
You can communicate with other RS-232 devices, such as scales, PCs, 9189 RF gateways, and printers, through the COM1 serial port. • •
6
You can use the COM2 serial port for:
RS-232, RS-422, or RS-485 serial communications Multi-Drop (CrossBar) network connectivity
Ethernet connector (2461 only) The 10BaseT Ethernet connector lets you connect the 2461 directly to an Ethernet network.
1-5
Page 24
TRAKKER Antares 246X Stationary Terminal User’s Manual
Using the Status Lights You can use the terminal’s status lights to monitor the status of backup battery power, network communications, special keys, and bar code scanning. The status lights only flash or turn on to indicate the current status. The Power status light is amber and all other lights are green. When you have the terminal turned off (Suspend mode), the status lights are also off.
2460
This status light turns on when you successfully scan a bar code label with an input device (badge scanner, laser scanner, and so on) that is connected to the terminal. The status light turns off after 2 seconds. You can also use the Status Lights Control reader command to turn this status light on and off. For help, see “Status Lights Control” in Chapter 7. Good Read
This status light is user defined. You can program this status light to turn on and off for any task or error within your application. You can also use the Status Lights Control reader command to turn this status light on and off. For help, see “Status Lights Control” in Chapter 7. User Defined
This status light tells you if the 2461 is connected to your Ethernet network. The Network Connect status light may be off, blinking, or on. Network Connect
Status Light Off
Status Light Blinks
Status Light On
Ethernet & TCP/IP
Not connected to the Ethernet network
Not used
Connected to the Ethernet network
Ethernet & UDP Plus
Not connected to the Ethernet network
Not connected to the DCS 300
Connected to the DCS 300
When the Network Connect status light is turned off, you are either not connected to the network or the terminal is not configured. Make sure the Network Activate command is enabled and that the terminal is configured correctly for your network. In a UDP Plus network, the Network Connect status light is not instantaneously updated but does tell you the communications status the last time data was sent or received from the terminal. For help with network communications, see Chapter 4, “Operating the Terminal in a Network.”
1-6
Page 25
Introducing the 246X Stationary Terminal
1
This status light indicates that one of the modifier keys on the keyboard is active. The modifier key is stored in the keyboard buffer until you press another key. When you press a second key, the key combination is entered into the terminal and the status light turns off. Examples of modifier keys include Ctrl, Alt, and Shift. You can also use the Status Lights Control reader command to turn this status light on and off. For help, see “Status Lights Control” in Chapter 7. Modifier
V
This status light remains off when you have power to the terminal, a charged backup battery, and the terminal is on. The light blinks when the backup battery has a low power charge or if you try to turn on the terminal with no external power supply connected to the terminal. The Power status light turns off once the backup battery charges. For help, see "Learning About the Power Supply and Backup Battery" later in this chapter. Power
Understanding the Terminal’s Status Beeps The 246X terminal has an internal speaker to emit beep sequences as you use the terminal. You can change the audio volume to meet the needs of your working environment by scanning bar code labels. To raise or lower the beep volume, scan one of these bar codes repeatedly
Lower Beep Volume
Raise Beep Volume
*$+BV8*
*$+BV9*
*$+BV8*
*$+BV9*
Note: If the Beep Volume is turned off, you will not hear any status beeps or keyclicks. For more information on changing the beep volume, see the Beep Volume command in Chapter 8, “Configuration Command Reference.” Use this table to understand the meaning of each beep sequence: Beep Sequence
Description
Low beep
You entered a valid command or the data you entered was stored.
High beep
You entered valid data, the terminal decoded a label, or the terminal decoded the last row of a two-dimensional (Code 16K or code 49) label.
Three low beeps
You entered or scanned an invalid command or data.
Four low beeps
When you boot the terminal, you hear four low beeps after the power-on self test (POST) has executed successfully.
Low beep, high beep, low beep, high beep
You hear this beep sequence when POST failed.
Click
You pressed a key on the keyboard or scanned a two-dimensional bar code label. You can disable the keyclick. For help, see “Keypad Clicker” in Chapter 8.
1-7
Page 26
TRAKKER Antares 246X Stationary Terminal User’s Manual
Learning About the Power Supply and Backup Battery The 246X terminal operates using an external power supply. It has a rechargeable NiCd (Nickel-Cadmium) backup battery that is designed to back up all memory and the realtime clock during a power loss. You must connect a power supply to the terminal for it to operate. You must purchase the power supply separately.
Understanding the Backup Battery The backup battery is a rechargeable NiCd battery that is designed to back up all memory and the real-time clock during a power loss. The backup battery provides protection for sags and dropouts. Here are the features of the backup battery: •
During a power loss, the terminal uses backup battery power to continue operating for 10 seconds. If power is still not restored, the terminal saves all data and turns off. However, if the backup battery charge is low, the terminal cannot protect the data against a power loss and will turn off immediately.
•
The backup battery is rechargeable. The terminal continuously monitors the backup battery voltage level and charges the backup battery whenever the voltage level gets low. The power supply provides the power to charge the backup battery whether the terminal is turned on or off.
•
The backup battery will last for a minimum of three years before its capacity is reduced. Battery life depends on the age of the backup battery and your usage. Using the terminal in extreme environments (very hot or very cold), reduces battery life and will require you to replace the backup battery more often.
•
The backup battery provides backup battery power for a minimum of 2 weeks if the battery is fully charged and no AC power is supplied. If you plan to store the terminal for a long period of time, save any data stored in RAM to another drive on the terminal. If the backup battery has remaining power when you reconnect it to the power supply and turn it on, the terminal resumes exactly where it was when you turned it off, or it restarts your application. Note: If the Resume Execution command is set to resume allowed, the terminal will resume the application when you turn on the terminal. Otherwise, the terminal boots and the application restarts.
1-8
Page 27
Introducing the 246X Stationary Terminal
1
Recognizing a Low or Discharged Backup Battery You can operate the terminal while the backup battery is charging. If the Power status light continues to blink after charging and the power supply is attached, the backup battery may be bad. If the backup battery will no longer hold a charge (Power status light is always blinking), you need to replace it. You need to back up all of your data stored in RAM. Any data stored in flash memory will be saved. For help, contact your local Intermec Service Representative. Note: The NiCd backup battery is NOT user-serviceable. You must return the 246X terminal to Intermec to replace the backup battery. Caution When you replace the backup battery, all data stored in RAM is lost. Conseil Lors du remplacement de la batterie de secours, toutes les données stockées dans la mémoire vive (RAM) sont perdues.
Defining the Terminal’s Memory and Drives The 246X stationary terminals come with the following memory and drives. You can store up to 32 files on each drive.
750K flash drive
Drive C Optional 2MB flash memory 256K configurable RAM drive
Drive D
Drive E 246XU.007
Drive C is a 750K flash drive on the 246X. Applications must be stored on drive C.
is an optional 2MB extended flash memory drive. If you have the optional 4MB flash memory, you can configure the extra 2MB of the flash memory as a 2MB drive (D). You may want to use this drive to store large lookup tables and data files. For help configuring the drive, see “Flash Memory Configuration” in Chapter 8. Drive D
1-9
Page 28
TRAKKER Antares 246X Stationary Terminal User’s Manual is a configurable RAM drive (up to 256K). By default, the RAM drive is not configured and the memory is available for programmable (Malloc) memory allocations. The contents of the RAM drive are erased when you boot or reset the terminal, or change the backup battery. For help configuring the drive, see “RAM Drive Size” in Chapter 8. Drive E
Note: On each drive, filenames are customer defined using eight characters with a three-character extension.
Where Do You Go From Here? Now that you understand the features and capabilities of your new 246X terminal, you can use this manual to learn how to perform these tasks:
1-10
Task
See This Chapter
Learn how to install the terminal and connect it to your network
Chapter 2, “Installing the Terminal”
Learn how to change the terminal’s configuration
Chapter 3, “Configuring the Terminal”
Learn how to use the terminal in your data collection system and learn about network protocols
Chapter 4, “Operating the Terminal in a Network”
Learn how to download and run custom applications on your programmable terminal
Chapter 5, “Programming the Terminal”
Page 29
2 Installing the Terminal
Page 30
blank page