Page 221
Nugg
Co d e
Configuration Command Reference 39
8
Scanner Selection Purpose:
Identifies the type of scanner you have connected to the 246X terminal. The terminal can optimize the scanning performance by using the scanner you define in this command. When you select a specific scanner, other scanners may not function properly. Your terminal may not work if you connect an incompatible scanner.
Syntax:
SSdata Acceptable values for data are: 0 1 3 4 5 6 7
All compatible scanners (including wands) 146X CCD scanners 151X laser scanners 1545 laser scanner Compatible Symbol scanners (with reverse polarity enabled) 155X laser scanners Long range laser scanner
Default:
All compatible scanners
Scan:
One of these bar codes: All Compatible Scanners
146X CCD Scanners
*$+SS0*
*$+SS1*
*$+SS0*
*$+SS1*
151X Laser Scanners
1545 Laser Scanner
*$+SS3*
*$+SS4*
*$+SS3*
*$+SS4*
Compatible Symbol Scanners
155X Laser Scanners
*$+SS5*
*$+SS6*
*$+SS5*
*$+SS6*
Long Range Laser Scanners
*$+SS7* *$+SS7*
8-73
Page 222
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Scanner Timeout Purpose:
Defines the maximum length of time the scanner stays on after you activate a laser scanner that is connected to the terminal.
Syntax:
SAdata Acceptable values for data are: 0 1-60
Default: Scan:
Disabled Shutoff time in seconds
Disabled (no timeout) To set the default scanner timeout, scan this bar code: Disable Scanner Timeout
*$+SA0* *$+SA0*
Or:
To set the scanner timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Scanner Timeout
*+/$+SA* *+/$+SA*
2. Scan a numeric value for data from these bar codes:
8-74
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
Page 223
Nugg
Co d e
Configuration Command Reference 39
8
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Scanner Trigger Purpose:
Syntax:
Scanner trigger allows you to set level triggering or edge triggering. •
With level triggering, you activate the scanner and the laser turns on and stays on until you release the trigger on the laser scanner.
•
In edge triggering, you activate the scanner and the laser turns on and stays on. When you activate the scanner a second time, the laser turns off. Simply releasing the trigger does not turn the laser off. If the laser is left on, the scanner timeout turns the laser off.
SCdata Acceptable values for data are: 0 1
Default: Scan:
Level triggering Edge triggering
Level triggering One of these bar codes: Enable Level Triggering
*$+SC0* *$+SC0* Enable Edge Triggering
*$+SC1* *$+SC1*
8-75
Page 224
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Serial Port Protocol Purpose:
Allows you to set the protocol that the serial port uses to communicate with a host or PC. Communications protocols determine exactly how data is transmitted between the terminal and the host or PC. Each protocol has parameters you can set, such as baud rate and parity. Both the terminal and the host or PC must use the same protocol and parameters settings to communicate properly. For help on protocols, see the Data Communications Reference Manual (Part No. 044737). The terminal can communicate in these five protocols: •
Binary
•
Configurable protocol
•
Master Polling
•
Polling Mode D
•
Multi-Drop
Note: You can only use Multi-Drop protocol on COM2 of the 2460. Each protocol is described in Chapter 4, “Operating the Terminal in a Network.” Syntax:
YUn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 0 2 3 8 12 Default: Scan:
Configurable Polling mode D Multi-drop Master polling mode D Binary
Configurable To set the default serial port protocol, scan one of these bar codes: Configurable Protocol for COM1
*$+YU1.0* *$+YU1.0*
8-76
Page 225
Nugg
Co d e
Configuration Command Reference 39
8
Configurable Protocol for COM2
*$+YU2.0* *$+YU2.0*
Or:
To set the serial port protocol: 1. Scan this bar code: Enter Accumulate Mode / Set Serial Port Protocol
*+/$+YU* *+/$+YU*
2. Scan one of these bar codes to set the COM port: COM1
COM2
*1.*
*2.*
*1.*
*2.*
3. Scan the protocol setting: Configurable
Polling Mode D
*0*
*2*
*0*
*2*
Multi-Drop
Master Polling
*3*
*8*
*3*
*8*
Binary
*12* *12*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-77
Page 226
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Start of Message (SOM) Purpose:
SOM is the first character in a message sent to or received from the host computer through the terminal’s serial port. SOM cannot equal the same value that is set for EOM. You cannot set SOM to any of these values: • • • • •
AFF (ACK) DLE NEG (NAK) Poll RES (EOT)
• • • •
REQ (ENQ) SEL XOFF XON
Note: Before you can enable SOM, you must configure the EOM command. Syntax:
YYn.data where n is: 1 2
COM1 port COM2 port
An acceptable value for data is any ASCII character. Default: Scan:
\x02 (hexadecimal value for STX) To disable SOM, scan one of these bar codes: Disable SOM for COM1
*$+YY1.* *$+YY1.* Disable SOM for COM2
*$+YY2.* *$+YY2.*
Or:
To set SOM to an ASCII character: Note: To scan the following bar codes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. 1. Scan this bar code: Enter Accumulate Mode / Set SOM
*+/$+YY* *+/$+YY*
8-78
Page 227
Nugg
Co d e
Configuration Command Reference 39
8
2. Scan one of these bar codes to set the COM port: COM1
COM2
*1.*
*2.*
*1.*
*2.*
3. Scan a bar code for data from the “Full ASCII Bar Code Chart” in Appendix B. 4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YY1.data
Or:
PEdata where data is any ASCII character. For COM2, you must use the YY configuration command.
Stop Bits Purpose:
Sets the number of stop bits on the serial port.
Syntax:
YCn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 1 2 Default: Scan:
1 stop bit 2 stop bits
1 To set the number of stop bits to 1, scan one of these bar codes: 1 Stop Bit for COM1
*$+YC1.1* *$+YC1.1*
8-79
Page 228
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Stop Bits (continued) 1 Stop Bit for COM2
*$+YC2.1* *$+YC2.1*
Or:
To set the number of stop bits to 2, scan one of these bar codes: 2 Stop Bits for COM1
*$+YC1.2* *$+YC1.2* 2 Stop Bits for COM2
*$+YC2.2* *$+YC2.2*
Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YC1.data
Or:
ICdata where data is a value of 1 or 2. For COM2, you must use the YC configuration command.
Subnet Mask Purpose:
Defines the subnet mask, an internal TCP/IP protocol stack variable that is used to separate the subnetwork address from the local IP address. The TCP/IP protocol stack performs a bit-wise AND on the IP address and the subnet mask. Each address segment represents one byte, where 255 converts to FF hex. This computation is used to find out if the DCS 300 (UDP Plus) or host (TCP/IP) and terminal are on different subnetworks. If the terminal is on a different IP subnetwork than the DCS 300 or host, you must set the subnet mask. The default subnet mask 255.255.255.0 means the 2461 terminal uses a standard IP network mask. For example, if the IP address is 192.009.150.184 and the subnet mask is 255.255.255.0, the subnetwork address is 192.009.150.0.
Syntax:
NSn.n.n.n where each n address segment is a number from 0 to 255. The subnet mask field consists of four separate numbers, each separated by a period.
Default:
8-80
255.255.255.0
Page 229
Nugg
Scan:
Co d e
Configuration Command Reference 39
8
To set the default subnet mask address, scan this bar code: Default Subnet Mask
*$+NS255.255.255.0* *$+NS255.255.255.0*
Or:
To set the subnet mask: 1. Scan this bar code: Enter Accumulate Mode / Set Subnet Mask
*+/$+NS* *+/$+NS*
2. Scan a numeric value from 0 to 255 to set an n field of the subnet mask address from these bar codes.
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: . (Period)
*.* *.*
4. Repeat Steps 2 and 3 to set the next three numbers in the subnet mask address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment.
8-81
Page 230
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Subnet Mask (continued)
5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Suspend/Resume Control Purpose:
Syntax:
W
W
W
Controls the operation of the button (suspend/resume). You can enable or disable the button. When the button is disabled, you cannot turn off the terminal. By default, the button is enabled so that you can turn the terminal on and off.
W
EFdata Acceptable values for data are: 0 1
Default: Scan:
Enabled Disabled
Enabled One of these bar codes: Enable
W
Button
*$+EF0* *$+EF0* Disable
W
Button
*$+EF1* *$+EF1*
8-82