Page 231

Nugg

Co d e

Configuration Command Reference 39

8

TCP Maximum Retries Purpose:

Defines the maximum number of times TCP will attempt to transmit data before giving up and terminating the TCP connection.

Syntax:

NJdata Acceptable values for data are any number from 5 to 50.

Default: Scan:

12 To set the default TCP maximum retries, scan this bar code: Default TCP Maximum Retries

*$+NJ12* *$+NJ12*

Or:

To set the TCP maximum retries: 1. Scan this bar code: Enter Accumulate Mode / Set TCP Maximum Retries

*+/$+NJ* *+/$+NJ*

2. Scan a numeric value for data from these bar codes:

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

8-83

Page 232

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

TCP Maximum Retries (continued)

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

TCP/IP Maximum Transmit Timeout Purpose:

Defines the maximum timeout that TCP will allow between retries of a transmission in a TCP/IP direct connect network before it gives up. For example, 20 means that the timeout between retries is never longer than 20 seconds. Intermec has determined that the optimum setting is 20 seconds.

Syntax:

NHdata Acceptable values for data are: 0 1-128

Default: Scan:

No timeout Transmit timeout in seconds

20 seconds To set the default TCP/IP maximum transmit timeout, scan this bar code: Default TCP/IP Maximum Transmit Timeout

*$+NH20* *$+NH20*

Or:

To set the TCP/IP maximum transmit timeout: 1. Scan this bar code: Enter Accumulate Mode / Set TCP/IP Maximum Transmit Timeout

*+/$+NH* *+/$+NH*

2. Scan a numeric value for data from these bar codes:

8-84

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

Page 233

Nugg

Co d e

Configuration Command Reference 39

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

8

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Terminal IP Address Purpose:

Defines the IP address assigned to the 2461 terminal in your Ethernet network. An IP address is a unique network level address you assign to each device in a TCP/IP network. The IP address you set on the 2461 must match the address that is set on the server or host computer.

Syntax:

NDn.n.n.n where each n address segment is a number from 0 to 255. The terminal IP address field consists of four separate numbers, each separated by a period. Note: The Ethernet network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.

Default: Scan:

0.0.0.0 To set the default terminal IP address, scan this bar code: Default Terminal IP Address

*$+ND0.0.0.0* *$+ND0.0.0.0*

8-85

Page 234

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Terminal IP Address (continued)

Or:

To set the terminal IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Terminal IP Address

*+/$+ND* *+/$+ND*

2. Scan a numeric value from 0 to 255 to set an n field of the terminal IP address from these bar codes.

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: . (Period)

*.* *.*

4. Repeat Steps 2 and 3 to set the next three numbers in the terminal IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

8-86

Page 235

Nugg

Co d e

Configuration Command Reference 39

8

Time and Date Purpose:

Sets the time and date on the terminal.

Syntax:

DBdata Acceptable values for data are 12 digits corresponding to: yy mm dd hh mm ss

00-99 01-12 01-31 00-23 00-59 00-59

Year Month of the year Day of the month Hour Minutes Seconds

Values for yy ranging from 00 to 95 are interpreted as 2000 through 2095. Values for yy ranging from 96 to 99 are interpreted as 1996 through 1999. Default: Scan:

960101000000 To set the time and date: 1. Scan this bar code: Enter Accumulate Mode / Set Time and Date

*+/$+DB* *+/$+DB*

2. Scan a numeric value for each digit from these bar codes:

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

8-87

Page 236

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Time and Date (continued)

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Time in Seconds Purpose:

If you enable the Append Time command, you can enable the Time in Seconds command to append the seconds to each bar code label that is scanned into the terminal. To append the time in hours and minutes, disable the Time in Seconds command.

Syntax:

DAdata Acceptable values for data are: 0 1

Default: Scan:

Disabled Enabled

Disabled One of these bar codes: Disable Time in Seconds

*$+DA0* *$+DA0* Enable Time in Seconds

*$+DA1* *$+DA1*

8-88

Page 237

Nugg

Co d e

Configuration Command Reference 39

8

Timeout Delay Purpose:

If handshaking is enabled, the terminal expects a response to each message that is sent to the host through the serial port. The timeout delay is the amount of time the terminal waits to receive a response. When the timeout expires, the terminal tries sending the message again. If no response is received, a timeout error occurs. Note: Before you enable Timeout Delay, you must configure EOM and Handshake.

Syntax:

YEn.data where n is: 1 2

COM1 port COM2 port

Acceptable values for data are: 0 1 2 3 4 5 6 7 Default: Scan:

5 ms 100 ms 500 ms 2 sec 10 sec 20 sec 40 sec 60 sec

10 seconds To set the default timeout delay, scan one of these bar codes: Timeout Delay 10 sec for COM1

*$+YE1.4* *$+YE1.4* Timeout Delay 10 sec for COM2

*$+YE2.4* *$+YE2.4*

Or:

To set the timeout delay: 1. Scan this bar code: Enter Accumulate Mode / Set Timeout Delay

*+/$+YE* *+/$+YE*

8-89

Page 238

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Timeout Delay (continued)

2. Scan one of these bar codes to set the COM port: COM1

COM2

*1.*

*2.*

*1.*

*2.*

3. Scan one of these bar codes for the timeout delay: Timeout Delay 5 ms

Timeout Delay 100 ms

*0*

*1*

*0*

*1*

Timeout Delay 500 ms

Timeout Delay 2 sec

*2*

*3*

*2*

*3*

Timeout Delay 10 sec

Timeout Delay 20 sec

*4*

*5*

*4*

*5*

Timeout Delay 40 sec

Timeout Delay 60 sec

*6*

*7*

*6*

*7*

4. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Notes:

For COM1 only, you can use either command syntax listed next: Syntax:

YE1.data

Or:

IEdata where data is a value from 0 to 7. For COM2, you must use the YE configuration command.

8-90

Page 239

Nugg

Co d e

Configuration Command Reference 39

8

UPC/EAN Purpose:

Enables or disables the decoding of Universal Product Code (UPC)/European Article Numbering (EAN) symbology. UPC/EAN are fixed length, numeric, continuous symbologies that use four element widths. A terminal that is configured to decode EAN bar codes can decode UPC, but the reverse is not true. UPC code is a subset of EAN code. To define the UPC/EAN symbology, you set up to seven digits. The fifth, sixth, and seventh digits are optional. To set the sixth digit, you must set the fifth digit. To set the seventh digit, you must set all seven digits.

Syntax:

CEdata where data must be 4 to 7 digits selected from this list:

Default:

First digit:

0 1 2

UPC-A/EAN-13 disabled UPC-A/EAN-13 enabled UPC-A only enabled

Second digit:

0 1

UPC-E disabled UPC-E enabled

Third digit:

0 1

EAN-8 disabled EAN-8 enabled

Fourth digit:

0 1 2

Supplementals are not allowed Supplementals are allowed Supplementals are required

Fifth digit:

0 1

Discard check digit Transmit check digit

Sixth digit:

0 1

Discard number system digit Transmit number system digit

Seventh digit:

0 1

Discard the leading zero for UPC-A Retain the leading zero for UPC-A

1111111 First digit: Second digit: Third digit: Fourth digit: Fifth digit: Sixth digit: Seventh digit:

UPC-A/EAN-13 enabled UPC-E enabled EAN-8 enabled Supplementals allowed Transmit check digit Transmit number system digit Retain leading zero for UPC-A

8-91

Page 240

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

UPC/EAN (continued)

Scan:

To disable UPC/EAN, scan this bar code: Disable UPC/EAN

*$+CE0000000* *$+CE0000000*

Or:

To enable UPC/EAN: 1. Scan this bar code: Enter Accumulate Mode / Enable UPC/EAN

*+/$+CE* *+/$+CE*

2. Scan one of these bar codes to set the first digit: Disable UPC-A/EAN-13

Enable UPC-A/EAN-13

*0*

*1*

*0*

*1*

Enable UPC-A Only

*2* *2*

3. Scan one of these bar codes to set the second digit: Disable UPC-E

Enable UPC-E

*0*

*1*

*0*

*1*

4. Scan one of these bar codes to set the third digit:

8-92

Disable EAN-8

Enable EAN-8

*0*

*1*

*0*

*1*