The text of a manual · part 22 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 211 to 220
Pages 211 to 220 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 211
Nugg
Scan:
Co d e
Configuration Command Reference 39
8
To disable poll, scan one of these bar codes: Disable Poll for COM1
*$+YR1.* *$+YR1.* Disable Poll for COM2
*$+YR2.* *$+YR2.*
Or:
To enable poll, scan one of these bar codes: Note: To scan the following bar codes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter. Enable Poll (Set to FS) for COM1
*/D/KYR1.%B* *$+YR1.%B* Enable Poll (Set to FS) for COM2
*/D/KYR2.%B* *$+YR2.%B*
Note: FS is encoded as %B in a Code 39 bar code label. Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YR1.data
Or:
HBdata where data is disabled or enabled (set to FS). For COM2, you must use the YR configuration command.
8-63
Page 212
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Postamble Purpose:
Sets the postamble that is appended to any data you scan with the terminal. Common postambles include cursor controls such as tabs or carriage return line feeds.
Syntax:
AEdata Acceptable values for data are up to 25 ASCII characters. If you enter the AE command without data, the postamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.
Default: Scan:
No characters (disabled) To disable the postamble, scan this bar code: Disable Postamble
*$+AE* *$+AE*
Or:
To set the postamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Postamble
*+/$+AE* *+/$+AE*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-64
Page 213
Nugg
Example:
Co d e
Configuration Command Reference 39
8
You want to set a postamble that includes quotation marks. Enter the postamble by scanning this full ASCII bar code label: Set Postamble to “B”
*/D/KAE/B/B/BB/B/B/B* *$+AE"""B"""*
You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.
Preamble Purpose:
Sets the preamble that precedes any data you scan with the terminal. Common preambles include a data location number or an operator number.
Syntax:
ADdata Acceptable values for data are up to 25 ASCII characters. When you enter the AD command without data, the preamble is disabled. If you are entering quotation marks as data or grouping configuration commands, you need to enclose the data within quotation marks (see the example). Note: To scan a bar code label that includes quotes, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” earlier in this chapter.
Default: Scan:
No characters (disabled) To disable the preamble, scan this bar code: Disable Preamble
*$+AD* *$+AD*
Or:
To set the preamble to an ASCII character string: 1. Scan this bar code: Enter Accumulate Mode / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble can be from 1 to 25 characters.
8-65
Page 214
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Preamble (continued)
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Example:
You want to set a preamble that includes quotation marks. Enter the preamble by scanning this full ASCII bar code label: Set Preamble to “B”
*/D/KAD/B/B/BB/B/B/B* *$+AD"""B"""*
You must enclose the data within quotation marks and precede each quotation mark with another quotation mark so that the quotation marks are not treated as the end of the data.
RAM Drive Size Purpose:
Configures the size and use of the RAM drive (E). You can disable the RAM drive and use the additional 256K for programmable (Malloc) memory allocations or configure the RAM drive to temporarily store data and files. Important: After you set the RAM drive, you must save the configuration in flash memory and boot the terminal for the change to take effect. Note: When you boot or reset the terminal, all files on the RAM drive are destroyed.
Syntax:
FRdata Acceptable values for data are: 0 16-256
Default: Scan:
Disabled, no RAM drive RAM drive size in kilobytes (K)
0 To disable the RAM drive, scan this bar code: Disable RAM Drive
*$+FR0* *$+FR0*
8-66
Page 215
Nugg
Or:
Co d e
Configuration Command Reference 39
8
To set the RAM drive size: 1. Scan this bar code: Enter Accumulate Mode / Set RAM Drive Size
*+/$+FR* *+/$+FR*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Scan this bar code to save the configuration change in flash memory: Save Configuration in Flash Memory
*.+1* *.+1*
5. Scan this bar code to boot the terminal and use the RAM drive: Reset Firmware
*-.* *-.*
8-67
Page 216
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Resume Execution Purpose:
Syntax:
W
ERdata Acceptable values for data are: 0 1
Default: Scan:
Not allowed Allowed
Allowed One of these bar codes: Resume Execution Not Allowed
*$+ER0* *$+ER0* Resume Execution Allowed
*$+ER1* *$+ER1*
8-68
W
Defines the way in which the terminal resumes when you press to turn on the terminal. If you set this parameter to resume not allowed and you press to turn on the terminal, the terminal will boot and restart the application that was running when you turned off the terminal. If you set this parameter to resume allowed and press to turn on the terminal, the terminal resumes using the application exactly where it was when you turned off the terminal.
W
Page 217
Nugg
Co d e
Configuration Command Reference 39
8
RS-232 or RS-422/485 COM2 Interface Purpose:
Defines the interface for the communications port. If you have a 2460 terminal, you can use COM2 for either RS-232 or RS-422/485 communications.
Syntax:
YK2.data Acceptable values for data are: 0 1
Default: Scan:
RS-232 RS-422/485
RS-232 To set the interface for COM2, scan one of these bar codes: Enable RS-232 Interface
*$+YK2.0* *$+YK2.0* Enable RS-422/485 Interface
*$+YK2.1* *$+YK2.1*
8-69
Page 218
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Scan Ahead Purpose:
Enables or disables scan ahead. If you enable this parameter, you can scan a number of labels that are held in a stack until the terminal can process the data. If you disable this parameter, the terminal processes each label you scan before you can scan the next label.
Syntax:
SDdata Acceptable values for data are: 0 1
Default: Scan:
Disabled (scan one label at a time) Enabled (scan many labels at a time)
Disabled One of these bar codes: Disable Scan Ahead
*$+SD0* *$+SD0* Enable Scan Ahead
*$+SD1* *$+SD1*
8-70
Page 219
Nugg
Co d e
Configuration Command Reference 39
8
Scanner Mode Purpose:
Syntax:
Defines how the scanner operates when you activate a laser scanner that is connected to the terminal. There are two types of modes: •
In One-Shot mode, you must activate the laser scanner each time you want to scan a bar code. Once you scan a bar code, the scanner turns off.
•
In Automatic (Auto-trigger) mode, you activate the laser scanner once to scan a series of bar codes. When you release the trigger, the scanner turns off. To scan the same bar code more than once, you must release the trigger, or scan a different bar code before attempting a second scan.
SBdata Acceptable values for data are: 0 1
Default: Scan:
One-Shot mode Automatic mode
One-Shot mode One of these bar codes: Enable One-Shot Mode
*$+SB0* *$+SB0* Enable Automatic Mode
*$+SB1* *$+SB1*
8-71
Page 220
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Scanner Redundancy Purpose:
Defines the number of scans (voting) the scanner takes of the same label that must decode correctly for a good read of the label. Voting requires the terminal to decode the same bar code multiple times during a single scanner event, and to compare the decoded information a specific number of times before signaling a good read. There are three options: Allows the terminal to accept the first good read, which speeds up terminal performance. This setting is recommended when scanning good quality bar codes.
None
The terminal decodes the bar code a minimum number of times in each scanner event. The number of comparisons that are made depends on each bar code symbology. Normal
The terminal scans and decodes the bar code a maximum number of times in each scanner event. The specific number of comparisons depends on each bar code symbology. The high setting is recommended when scanning poor quality labels that may cause substitution errors. High
For example, when you scan Code 39 labels and the scanner redundancy is set to normal, two successive matching decodes in a single scanner event are required. When scanner redundancy is set to high, three successive matching decodes in a single scanner event are required. Syntax:
SRdata Acceptable values for data are: 0 1 2
Default: Scan:
None Normal High
Normal One of these bar codes: Scanner Redundancy None
Scanner Redundancy Normal
*$+SR0*
*$+SR1*
*$+SR0*
*$+SR1*
Scanner Redundancy High
*$+SR2* *$+SR2*
8-72