The text of a manual · part 21 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 201 to 210
Pages 201 to 210 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 201
Nugg
Co d e
Configuration Command Reference 39
8
Keypad Clicker Purpose:
Enables or disables the keypad clicks. The terminal sounds a click each time you press a key or decode a row of a two-dimensional symbology. Note: If the Beep Volume is turned off, you will not hear any audio signals including the keyclick.
Syntax:
KCdata Acceptable values for data are: 0 1
Default: Scan:
Disable keypad clicker Enable keypad clicker
Enabled One of these bar codes: Disable Keypad Clicker
Enable Keypad Clicker
*$+KC0*
*$+KC1*
*$+KC0*
*$+KC1*
8-53
Page 202
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
LRC (Longitudinal Redundancy Check) Purpose:
The Longitudinal Redundancy Check (LRC) character is an error-checking character that you can append to transmitted and received blocks of data. Note: Before you can enable LRC, you must configure the EOM command.
Syntax:
YFn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 0 1 Default: Scan:
LRC disabled LRC enabled
Disabled To disable LRC, scan one of these bar codes: Disable LRC for COM1
*$+YF1.0* *$+YF1.0* Disable LRC for COM2
*$+YF2.0* *$+YF2.0*
Or:
To enable LRC, scan one of these bar codes: Enable LRC for COM1
*$+YF1.1* *$+YF1.1* Enable LRC for COM2
*$+YF2.1* *$+YF2.1*
Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YF1.data
Or:
IFdata
Where data is a value of 0 or 1. For COM2, you must use the YF configuration command.
8-54
Page 203
Nugg
Co d e
Configuration Command Reference 39
8
MSI Purpose:
Enables or disables decoding of MSI symbology. MSI code is similar to Plessey code. MSI code includes a start pattern, data characters, one or two check digits, and a stop pattern.
Syntax:
CNdata Acceptable values for data are:
Default: Scan:
First digit:
0 1 2 3
Disabled No check digits 1 modulus 10 check digit 2 modulus 10 check digit
Second digit:
0 1
Discard check digit Transmit check digit
Disabled One of these bar codes: Disable MSI
*$+CN00* *$+CN00* MSI Without Check Digits
*$+CN10* *$+CN10* MSI With 1 Modulus 10 Check Digit, Discard Check Digit
*$+CN20* *$+CN20* MSI With 1 Modulus 10 Check Digit, Transmit Check Digit
*$+CN21* *$+CN21* MSI With 2 Modulus 10 Check Digits, Discard Check Digits
*$+CN30* *$+CN30* MSI With 2 Modulus 10 Check Digits, Transmit Check Digits
*$+CN31* *$+CN31*
8-55
Page 204
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Multi-Drop Address Purpose:
Syntax:
Defines the address of the communications port when you are using Multi-Drop protocol on COM2. Each multi-drop address has unique POL and SEL characters that are automatically set when you configure the address. The POL and SEL combination for each address is listed next. Address
POL
SEL
Address
POL
SEL
A
FS
GS
Q
<
=
B
RS
US
R
>
?
C
SP
!
S
@
A
D
“
#
T
B
C
E
$
%
U
D
E
F
&
‘
V
F
G
G
(
)
W
H
I
H
*
+
X
J
K
I
‘
-
Y
L
M
J
.
/
Z
N
O
K
0
1
0
P
Q
L
2
3
1
R
S
M
4
5
2
T
U
N
6
7
3
V
W
O
8
9
4
X
Y
P
:
;
5
Z
[
YN2.data where data can be an alphanumeric value from A through Z or 0 to 5.
Default: Scan:
A To set the default multi-drop address: Default Multi-Drop Address (A) for COM2
*$+YN2.A* *$+YN2.A*
8-56
Page 205
Nugg
Or:
Co d e
Configuration Command Reference 39
8
To set the multi-drop address: 1. Scan this bar code: Enter Accumulate Mode / Set Multi-Drop Address
*+/$+YN2.* *+/$+YN2.*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The address is a single alphanumeric character from A through Z or 0 to 5. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Network Activate Purpose:
Enables or disables network communications between the 2461 terminal and other devices in the Ethernet network. When you enable this parameter, the terminal attempts to establish communications with the DCS 300 server or host computer. When you disable this parameter, the network is disabled. Note: You must enable the Network Activate parameter to use the 2461 for data collection in your Ethernet network.
Syntax:
NAdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Ethernet network (enabled)
Disabled One of these bar codes: Disable Network Activate
*$+NA0* *$+NA0* Enable Ethernet Network
*$+NA1* *$+NA1*
8-57
Page 206
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Network Port Purpose:
Defines the network port that the TCP/IP or UDP Plus network protocol uses for communications in your Ethernet network. In a TCP/IP network, set the network port to the appropriate port for the application you are using on the 2461 terminal In a UDP Plus network, the network port you set on the 2461 must match the network port that is set on the DCS 300 server.
Syntax:
NGdata Acceptable values for data are any number from 1 to 65535.
Default:
Scan:
00023 05555
2461 with TCP/IP network protocol 2461 with UDP Plus network protocol
To set the default network port for a 2461 with TCP/IP, scan this bar code: Default TCP/IP Network Port
*$+NG23* *$+NG23*
To set the default network port for a 2461 with UDP Plus, scan this bar code: Default UDP Plus Network Port
*$+NG5555* *$+NG5555*
Or:
To set the network port: 1. Scan this bar code: Enter Accumulate Mode / Set Network Port
*+/$+NG* *+/$+NG*
8-58
Page 207
Nugg
Co d e
Configuration Command Reference 39
8
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-59
Page 208
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Parity Purpose:
Sets the parity for the serial port. The terminal uses parity for error checking in data transmissions.
Syntax:
YBn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 0 1 2 Default: Scan:
No parity Even parity Odd parity
Even To set the default parity, scan one of these bar codes: Even Parity for COM1
*$+YB1.1* *$+YB1.1* Even Parity for COM2
*$+YB2.1* *$+YB2.1*
Or:
To set the parity: 1. Scan this bar code: Enter Accumulate Mode / Set Parity
*+/$+YB* *+/$+YB*
2. Scan one of these bar codes to set the COM port:
8-60
COM1
COM2
*1.*
*2.*
*1.*
*2.*
Page 209
Nugg
Co d e
Configuration Command Reference 39
8
3. Scan the parity setting: No Parity
Even Parity
*0*
*1*
*0*
*1*
Odd Parity
*2* *2*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to set the parity for another serial port. Notes:
For COM1 only, you can use either command syntax listed next: Syntax: YB1.data Or:
IBdata where data is a value from 0 to 2 for the parity. For COM2, you must use the YB configuration command.
Plessey Purpose:
Enables or disables decoding of Plessey symbology. Plessey code is pulse-width modulated like most other bar codes. It includes a start character, data characters, an eight-bit cyclic check digit, a termination bar, and usually a reverse start character. The code is continuous and not self-checking. You need to configure two parameters for Plessey code: Start Code and Check Digit.
Syntax:
CIdata Acceptable values for data are: 00 10 30 31
Default:
Disabled Plessey with reverse start code Transmit check digit Discard check digit
Disabled
8-61
Page 210
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Plessey (continued)
Scan:
To disable Plessey: Disable Plessey
*$+CI00* *$+CI00*
Or:
To set Plessey, complete these steps: 1. Scan this bar code: Plessey With Reverse Start Code
*$+CI10* *$+CI10*
2. Scan one of these bar codes to transmit or retain the check digit: Transmit Check Digit
Discard Check Digit
*$+CI30*
*$+CI31*
*$+CI30*
*$+CI31*
Poll (Polling) Purpose:
Solicits or requests data from a polled device. Note: Before you can enable Poll, you must configure the EOM and Handshake commands.
Syntax:
YRn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: Disabled Enabled Default:
8-62
Disabled
No polling Set to FS (File Separator, hexadecimal value \x1c)