Page 161

Nugg

Co d e

8

Configuration Command Reference 39

The next table lists the ASCII characters that change for the seven European languages. Only these 11 characters change in any character set. All other characters in the ASCII chart remain as defined in the “Full ASCII Table” in Appendix B. Country

Hexadecimal Value

23

40

5B

5C

5D

5E

60

7B

7C

7D

7E

United States

#

@

[

\

]

^

'

{

¦

}

~

England

£

@

[

\

]

^

'

{

¦

}

~

Germany

#

§

Ä

Ö

Ü

^

'

ä

ö

ü

ß

Denmark

#

@

Æ

Ø

Å

^

'

æ

ø

å

~

France

#

à

°

ç

§

^

'

é

ù

è

¨

Sweden

#

É

Ä

Ö

Å

Ü

é

ä

ö

å

ü

Italy

#

@

°

ç

é

^

ù

à

ò

è

ì

Spain t

@

¡

Ñ

¿

^

'

¨

ñ

}

~

8-13

Page 162

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Codabar Purpose:

Enables or disables decoding of Codabar symbology. Codabar is a self-checking, discrete symbology. The American Blood Commission (ABC) Codabar requires that you retain and transmit the start/stop code digits when processing a Codabar symbol. As a result, configuration CD10 is an illegal configuration.

Syntax:

CDdata Acceptable values for data must be two digits, corresponding to:

Default: Scan:

Digit

Value

Description

First

0 1 2 3

Disabled ABC Standard Concatenated

Second

0 1 2

Discard Start/Stop Transmit ABCD Start/Stop Transmit DC1-DC4 Start/Stop

Disabled One of these bar codes: Disabled, Discard Start/Stop

*$+CD00*

*$+CD11*

*$+CD00*

*$+CD11*

ABC, Transmit DC1-DC4 Start/Stop

Standard, Discard Start/Stop

*$+CD12*

*$+CD20*

*$+CD12*

*$+CD20*

Standard, Transmit ABCD Start/Stop

Standard, Transmit DC1-DC4 Start/Stop

*$+CD21*

*$+CD22*

*$+CD21*

*$+CD22*

Concatenated, Discard Start/Stop

Concatenated, Transmit ABCD Start/Stop

*$+CD30*

*$+CD31*

*$+CD30*

*$+CD31*

Concatenated, Transmit DC1-DC4 Start/Stop

*$+CD32* *$+CD32*

8-14

ABC, Transmit ABCD Start/Stop

Page 163

Nugg

Co d e

Configuration Command Reference 39

8

Code 11 Purpose:

Enables or disables decoding of Code 11 symbology. Code 11 is a very high density, discrete numeric bar code. It is most extensively used in labeling telecommunications components and equipment.

Syntax:

CGdata Acceptable values for data are: 0 1 2

Default: Scan:

Disabled Code 11 enabled with one check digit Code 11 enabled with two check digits

Disabled One of these bar codes: Disable Code 11

*$+CG0* *$+CG0* Code 11 Enabled With One Check Digit

*$+CG1* *$+CG1* Code 11 Enabled With Two Check Digits

*$+CG2* *$+CG2*

8-15

Page 164

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Code 16K Purpose:

Enables or disables decoding of Code 16K symbology. Code 16K is a two-dimensional (stacked rows), high density bar code. It is based on Code 128 and is used widely to label unit-dose packaging for the healthcare industry.

Syntax:

CPdata Acceptable values for data are: 0 1 2

Disabled Standard Code 16K enabled Code 16K enabled with Function Code 1

When you enable Code 16K with Function Code 1, the terminal decodes the bar code label and checks for a Function Code 1 in the first data character position. If a Function Code 1 is the first character, the terminal substitutes this Code 16K symbology identifier string for the Function Code 1 character: ]K1

Default: Scan:

Disabled One of these bar codes: Disable Code 16K

*$+CP0* *$+CP0* Standard Code 16K Enabled

*$+CP1* *$+CP1* Code 16K Enabled With Function Code 1

*$+CP2* *$+CP2*

8-16

Page 165

Nugg

Co d e

Configuration Command Reference 39

8

Code 2 of 5 Purpose:

Enables or disables decoding of Code 2 of 5 symbology. Code 2 of 5 uses the bars to encode information and the spaces to separate the individual bars. This code is discrete and self-checking. You can only enable Code 2 of 5 if the Interleaved 2 of 5 (I 2 of 5) code is disabled. If you enable I 2 of 5, Code 2 of 5 is automatically disabled.

Syntax:

CCdata where data consists of three digits as follows:

Default: Scan:

First digit:

0 1

Code 2 of 5, 3 Bar Start/Stop Code 2 of 5, 2 Bar Start/Stop

Second and third digits:

00 01-32

Disable Code 2 of 5 Label Length

Disabled To disable Code 2 of 5, scan this bar code: Disable Code 2 of 5

*$+CC000* *$+CC000*

Or:

To enable Code 2 of 5: 1. Scan one of these bar codes: Code 2 of 5, 3 Bar Start/Stop

*+/$+CC0* *+/$+CC0* Code 2 of 5, 2 Bar Start/Stop

*+/$+CC1* *+/$+CC1*

8-17

Page 166

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

2. Scan a two-digit numeric value to set the label length (01-32) from these bar codes.

*0*

*1*

*0*

*1*

*2*

*3*

*2*

*3*

*4*

*5*

*4*

*5*

*6*

*7*

*6*

*7*

*8*

*9*

*8*

*9*

3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

Code 39 Purpose:

Enables or disables decoding of Code 39 symbology. Code 39 is discrete, variable length, and self-checking. The character set is uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/), percent (%), space ( ), plus (+), and minus (-). There are three types of ASCII the terminal decodes: •

Code 39 non-full ASCII

•

Code 39 full ASCII

•

Code 39 mixed-full ASCII

Non-full ASCII uses a one-character encoding scheme. For example, you encode the data “SAMPLE” as follows: Code 39 non-full ASCII

*SAMPLE* *SAMPLE*

This label decodes as SAMPLE.

8-18

Page 167

Nugg

Co d e

Configuration Command Reference 39

8

Full ASCII uses a two-character encoding scheme to extend the character set to 128 characters. You use the dollar sign ($), slash (/), percent (%), or plus (+) followed by an uppercase letter to represent one of the characters in the extended set. You must encode lowercase letters as a plus sign (+) followed by their uppercase equivalents. For a list of ASCII characters and their Code 39 representations, see the “Full ASCII Table” in Appendix B. Code 39 full ASCII

Use Code 39 full ASCII to enter ASCII control characters or lowercase characters as data. You should also enable Code 39 full ASCII to use ASCII command characters. For example, you encode the data “sample” in Code 39 full ASCII as follows:

*+S+A+M+P+L+E* *+S+A+M+P+L+E*

In Code 39 non-full ASCII, this label decodes as +S+A+M+P+L+E. In Code 39 full ASCII, this label decodes as sample. Use mixed-full ASCII when printers encode the same label two different ways. For example, if you have a bar code with the data $%a, some printers encode the data as follows: Code 39 mixed-full ASCII

*/D/E+A* */D/E+A*

In the Full ASCII Table in Appendix B, /D represents $ and /E represents %. If you configure the terminal for Code 39 full ASCII, the terminal decodes the data as $%a because there are three valid full ASCII character pairs to represent the data. Other printers encode the data $%a as:

*$%+A* *$%+A*

The $ and % are valid Code 39 characters in the non-full ASCII character set. However, the terminal will not decode this label if it is configured for full ASCII, because the data is not represented by valid full ASCII character pairs. To decode the label correctly, you need to configure the terminal for mixed-full ASCII. When you configure the terminal for Code 39 mixed-full ASCII, the terminal will decode both of the labels above as $%a. Mixed-full ASCII interprets any valid full ASCII character pairs that appear in the label, but does not require that all data be encoded with a valid full ASCII character pair. If you are uncertain how your labels are encoded, configure the terminal for mixed-full ASCII, which decodes all valid Code 39 labels. If you configure the terminal for Code 39 full ASCII, you should check for Code 39 mixed-full ASCII. Mixed-full ASCII does not apply when you configure the terminal for non-full ASCII.

8-19

Page 168

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Code 39 (continued)

Note: The interpretive text shown under bar code labels does not always accurately reflect the data that is encoded in the label. The interpretive text represents how the label should be decoded. Use this table to help configure your terminal.

Syntax:

Code 39 Option

Bar Code Label

Decodes

Non-full ASCII

$%+A /D/E+A

$%+A /D/E+A

Full ASCII

$%+A /D/E+A

No decode $%a

Mixed-full ASCII

$%+A /D/E+A

$%a $%a

CBdata Acceptable values for data must be three digits, corresponding to: First digit:

0 1 2 3 4

Disabled Enabled with no check digit Enabled with check digit HIBC (Health Industry Bar Code) With AIAG check digit

Second digit:

0 1

Discard check digit Transmit check digit

Third digit:

0 1 2

Code 39 non-full ASCII Code 39 full ASCII Code 39 mixed-full ASCII

Note: Selecting HIBC Code 39 automatically sets the configuration to non-full ASCII with the check digit transmitted. Default: Scan:

Enable Code 39 Full ASCII with no check digit (111) To disable Code 39: Disable Code 39

*$+CB0* *$+CB0*

8-20

Page 169

Nugg

Or:

Co d e

Configuration Command Reference 39

8

To enable Code 39: 1. Scan this bar code: Enter Accumulate Mode / Enable Code 39

*+/$+CB* *+/$+CB*

2. Scan one of these bar codes to set the first digit: Without a Check Digit

With a Check Digit

*1*

*2*

*1*

*2*

HIBC Code 39

With AIAG Check Digit

*3*

*4*

*3*

*4*

3. Scan one of these bar codes to set the second digit: Discard Check Digit

Transmit Check Digit

*0*

*1*

*0*

*1*

4. Scan one of these bar codes to set the third digit: Code 39 Non-Full ASCII

Code 39 Full ASCII

*0*

*1*

*0*

*1*

Code 39 Mixed-Full ASCII

*2* *2*

5. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

8-21

Page 170

TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg

Co d e

39

Code 49 Purpose:

Enables or disables decoding of Code 49 symbology. Code 49 is a multirow symbology for high data density. The last character in each row is used for row checking and the last two characters of the symbol are used for overall checking. Function codes designate where to place the predefined data string in a Code 49 label. Whenever a terminal encounters a function code, it replaces the function code with the defined string before transmitting the data to the DCS 300. A single Code 49 symbol may contain several different variable length data fields. Function Code 1 (F1) identifies a data system. Function Code 2 (F2) indicates the end of a data field.

Syntax:

CJdata CKdata CLdata CMdata

Code 49 Function Code 1 Function Code 2 Function Code 3

Acceptable values for data are:

Default: Scan:

Code 49:

0 1

Function Code 1:

Any two ASCII characters.

Function Code 2:

Any four ASCII characters

Function Code 3:

Any two ASCII characters

Disabled One of these bar codes: Disable Code 49

Scan:

Enable Code 49

*$+CJ0*

*$+CJ1*

*$+CJ0*

*$+CJ1*

To disable any of the function codes, scan one of these bar codes: Disable Function Code 1

Disable Function Code 2

*$+CK*

*$+CL*

*$+CK*

*$+CL*

Disable Function Code 3

*$+CM* *$+CM*

8-22

Disabled Enabled