Page 171
Nugg
Or:
Co d e
Configuration Command Reference 39
8
To set one of the function codes to a character string: 1. Scan one of these bar codes: Enter Accumulate Mode / Set Function Code 1
*+/$+CK* *+/$+CK* Enter Accumulate Mode / Set Function Code 2
*+/$+CL* *+/$+CL* Enter Accumulate Mode / Set Function Code 3
*+/$+CM* *+/$+CM*
2. Scan any character from the “Full ASCII Bar Code Chart” in Appendix B. You can define two characters each for Function Codes 1 and 3, and four characters for Function Code 2. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Code 93 Purpose:
Enables or disables decoding of Code 93 symbology. Code 93 is a variable length, continuous symbology that uses four element widths.
Syntax:
CFdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Enabled
Disabled One of these bar codes: Disable Code 93
Enable Code 93
*$+CF0*
*$+CF1*
*$+CF0*
*$+CF1*
8-23
Page 172
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Code 128 Purpose:
Enables or disables decoding of Code 128 symbology. Code 128 is a very high density alphanumeric symbology that supports the extended ASCII character set. It is a variable length, continuous code that uses multiple element widths.
Syntax:
CHdata Acceptable values for data are: 0 1 2 8
Disabled Standard Code 128 UCC/EAN Code 128 ISBT Code 128
Note: For help configuring ISBT Code 128, see “ISBT Code 128” later in this chapter. Default: Scan:
Notes:
Standard One of these bar codes: Disable Code 128
Enable Standard Code 128
*$+CH0*
*$+CH1*
*$+CH0*
*$+CH1*
Enable UCC/EAN Code 128
Enable ISBT Code 128
*$+CH2*
*$+CH8*
*$+CH2*
*$+CH8*
If you configure Standard Code 128, the terminal will not decode Function Code 1 characters in the first position of a bar code label. Any subsequent Function Code 1 characters are translated to the ASCII GS character as a separator for variable length fields. If you configure UCC/EAN Code 128, the terminal will decode a bar code label as Standard Code 128 unless one of the first two characters are a start character and a Function Code 1. In this case, the bar code label is processed as described next: 1. The Function Code 1 character is not transmitted. 2. The three symbology ID characters, ]C1, are transmitted. 3. The remaining Code 128 characters are decoded as Standard Code 128.
8-24
Page 173
Nugg
Co d e
Configuration Command Reference 39
8
Command Processing Purpose:
Command processing allows you to disable or enable reader commands. Use the Command Processing configuration command described here to configure the reader commands. You may want to disable reader commands to prevent a user from accidentally entering a command, or to use data that would otherwise be treated as a command. Any Code 39 or Code 93 bar code label that contains the 2- to 4-character commands for Command Processing is treated as a reader command unless the command is disabled. For a description of each reader command that you can enable or disable with Command Processing, see Chapter 7, “Reader Command Reference.”
Syntax:
DCdata Acceptable values for data are: 0 1 2 3 command0 command1
Disable all reader commands Enable all reader commands Disable override Enable override Disable reader command Enable reader command
The override option is a temporary setting that allows you to enable all the reader commands for as long as you need them. When you want to return to the previous configuration, you disable the override. Note: The Enable Override option is the only bar code label you can scan to enable reader commands if you have disabled all reader commands (DC0). Default: Scan:
All reader commands enabled To enable all the reader commands or override the current settings, scan one of these bar codes: Disable All Reader Commands
Enable All Reader Commands
*$+DC0*
*$+DC1*
*$+DC0*
*$+DC1*
Disable Override
Enable Override
*$+DC2*
*$+DC3*
*$+DC2*
*$+DC3*
8-25
Page 174
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Command Processing (continued)
Or:
To disable or enable specific reader commands, perform these steps: 1. Scan this bar code: Enter Accumulate Mode / Command Processing
*+/$+DC* *+/$+DC*
2. Scan the bar code to disable or enable one reader command. Note: If there are two bar codes for a reader command, you must scan them in order, left to right. Accumulate mode commands are separated into two bar codes so that the command can be accumulated rather than executed as a command. Abort Program
*/$* */$*
8-26
Backspace
(continued)
*-*
*+*
*-*
*+*
Boot Terminal
Change Configuration
*-.1*
*$+*
*-.*
*$+*
Clear
(continued)
*-*
*-*
*-*
*-*
Default/Save Configuration
Delete File
*.+*
*..--*
*.+*
*..--*
Enter Accumulate Mode
(continued)
*+*
*/*
*+*
*/*
Exit Accumulate Mode
(continued)
*-*
*/*
*-*
*/*
Page 175
Nugg
Co d e
Configuration Command Reference 39
Receive File
Rename File
*.%*
*...-*
*.%*
*...-*
Reset
Run Program
*-.*
*//*
*-.*
*//*
Scanner Trigger Off
Scanner Trigger On
*/%*
*/.*
*/%*
*/.*
Set Time and Date
Status Lights Control
*/+*
*$%*
*/+*
*$%*
8
Transmit File
*%%* *%%*
3. Scan one of these bar codes: Disable the Command
Enable the Command
*0*
*1*
*0*
*1*
4. Repeat Steps 2 and 3 to disable or enable another reader command. Note: You can accumulate up to 250 characters in the buffer. If the data accumulated exceeds 250 characters, you will hear an error beep and the terminal will reject the last bar code read. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-27
Page 176
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Command Processing (continued)
Or:
To disable or enable the ability to scan multiple-read labels, scan one of these bar codes: Disable Multiple-Read Labels
Enable Multiple-Read Labels
*$+DC 0*
*$+DC 1*
*$+DC 0*
*$+DC 1*
Configuration Commands Via Serial Port Purpose:
Allows you to control the data the terminal receives through the serial port. You can set this command to execute reader and configuration commands received through the serial port, or treat all data as data without checking for special command syntax. There are three options: All data received through the serial port is treated as data. The terminal will not execute reader or configuration commands sent or encoded in the data.
Disabled
If the data is sent with the TMF (Terminal Message Format) header, the terminal will check for and execute the TMF command received through the serial port. With TMF, you can execute reader and configuration commands, or send and receive data about the current terminal configuration. Enabled with TMF
The terminal will check for and execute all reader and configuration commands (i.e., Receive File reader command or Beep Volume change configuration command). Enabled without TMF
Note: Before you can enable Configuration Commands Via Serial Port with or without TMF, you must configure the EOM command. Syntax:
YTn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 0 1 2 Default:
8-28
Disabled Enabled with TMF Enabled without TMF
Enabled without TMF
Page 177
Nugg
Scan:
Co d e
Configuration Command Reference 39
8
To set the default configuration, scan one of these bar codes: Default Configuration for COM1
*$+YT1.2* *$+YT1.2* Default Configuration for COM2
*$+YT2.2* *$+YT2.2*
Or:
To set the configuration commands: 1. Scan this bar code: Enter Accumulate Mode / Set Configuration Commands Via Serial Port
*+/$+YT* *+/$+YT*
2. Scan one of these bar codes to set the COM port: COM1
COM2
*1.*
*2.*
*1.*
*2.*
3. Scan the configuration command: Disabled
Enabled With TMF
*0*
*1*
*0*
*1*
Enabled Without TMF
*2* *2*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
5. Repeat Steps 1 through 4 to set the configuration commands via serial port for another serial port.
8-29
Page 178
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Configuration Commands Via Serial Port (continued)
Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YT1.data
Or:
ITdata where data is a value from 0 to 2. For COM2, you must use the YT configuration command.
Controller IP Address Purpose:
Defines the IP address assigned to the DCS 300 server in your Ethernet network. An IP address is a network level address you assign to each device in a TCP/IP network. The controller IP address you set on the 2461 terminal must match the address that is set on the DCS 300. If you plan to enable DHCP (Dynamic Host Configuration Protocol), you can set the controller IP address to any valid IP address. The T2461 will locate and reset the IP address after you enable DHCP. For help, see “Dynamic Host Configuration Protocol (DHCP)” later in this chapter.
Syntax:
NCn.n.n.n where each n address segment is a number from 0 to 255. The controller IP address field consists of four separate numbers, each separated by a period. Note: The Ethernet network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
Default: Scan:
0.0.0.0 To set the default controller IP address, scan this bar code: Default Controller IP Address
*$+NC0.0.0.0* *$+NC0.0.0.0*
Or:
To set the controller IP address: 1. Scan this bar code: Enter Accumulate Mode / Set Controller IP Address
*+/$+NC* *+/$+NC*
8-30
Page 179
Nugg
Co d e
Configuration Command Reference 39
8
2. Scan a numeric value from 0 to 255 to set an n field of the controller IP address from these bar codes.
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: . (Period)
*.* *.*
4. Repeat Steps 2 and 3 to set the next three numbers in the controller IP address field. After you scan the last address segment, go to Step 5. Do not scan the period after the last address segment. 5. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-31
Page 180
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Data Bits Purpose:
Sets the number of data bits the terminal uses when communicating with another device (i.e., host computer) through the serial port.
Syntax:
YIn.data where n is: 1 2
COM1 port COM2 port
Acceptable values for data are: 7 8 Default: Scan:
7 data bits 8 data bits
7 To set the default data bits, scan one of these bar codes: Default Data Bits for COM1
*$+YI1.7* *$+YI1.7* Default Data Bits for COM2
*$+YI2.7* *$+YI2.7*
Or:
To set the data bits: 1. Scan this bar code: Enter Accumulate Mode / Set Data Bits
*+/$+YI* *+/$+YI*
2. Scan one of these bar codes to set the COM port:
8-32
COM1
COM2
*1.*
*2.*
*1.*
*2.*