The text of a manual · part 16 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 151 to 160
Pages 151 to 160 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 151
Nugg
Co d e
Configuration Command Reference 39
8
This chapter is an alphabetical list of all the configuration commands supported on the terminal.
Using Configuration Commands A configuration command changes the way the terminal operates. For example, you can change the Beep Volume and make the terminal beep very loud in a noisy environment. You can execute configuration commands by • scanning a command from a Code 39 or Code 93 bar code label. These labels are provided in this chapter. For more help, see Chapter 3, “Configuring the Terminal.”
• sending a command from a device on the serial or Ethernet network. For help, see “Using Serial Communications on the Terminal” and “Using Ethernet Communications on the Terminal” in Chapter 4.
You can find the following information about each configuration command in this chapter: •
Command description and purpose
•
Command syntax and options
•
Default setting
•
Bar code labels you can scan to set or change each command
The configuration commands are listed alphabetically by command name. For a list of bar code symbology, operations, serial network communications, or Ethernet network communications commands, use the next table, “Configuration Commands Listed by Category.” If you want to look up a command by its syntax, see the “Configuration Commands by Syntax” list in Appendix A. Some of the bar code labels in this chapter include quotes or other characters from the full ASCII character set. To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
8-3
Page 152
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Configuration Commands Listed by Category This chapter lists the configuration commands in alphabetical order. Use this next list to find the configuration commands you may need to set for bar code symbologies, operations, serial network communications, or Ethernet network communications. Bar Code Symbologies
Ethernet Network Communications
Codabar, 8-14
Controller IP Address, 8-30
Code 11, 8-15
Default Router, 8-34
Code 16K, 8-16
Dynamic Host Configuration Protocol (DHCP), 8-36
Code 2 of 5, 8-17
Host IP Address, 8-43
Code 39, 8-18
Network Activate, 8-57
Code 49, 8-22
Network Port, 8-58
Code 93, 8-23
Subnet Mask, 8-80
Code 128, 8-24
TCP Maximum Retries, 8-83
Interleaved 2 of 5, 8-45
TCP/IP Maximum Transmit Timeout, 8-84
ISBT Code 128, 8-47
Terminal IP Address, 8-85
MSI, 8-55 Plessey, 8-61 UPC/EAN, 8-91
8-4
Page 153
Nugg
Co d e
Configuration Command Reference 39
8
Configuration Commands Listed by Category (continued) Operations
Serial Network Communications
Append Time, 8-7
Baud Rate, 8-9
Automatic Shutoff, 8-7
Configuration Commands Via Serial Port, 8-28
Beep Volume, 8-11
Data Bits, 8-32
Character Set, 8-12
End of Message (EOM), 8-37
Command Processing, 8-25
Flow Control, 8-40
Decode Security, 8-33
Handshake, 8-42
Flash Memory Configuration, 8-39
LRC (Longitudinal Redundancy Check), 8-54
Keypad Caps Lock, 8-52
Multi-Drop Address, 8-56
Keypad Clicker, 8-53
Parity, 8-60
Postamble, 8-64
Poll (Polling), 8-62
Preamble, 8-65
RS-232 or RS-422/485 COM2 Interface, 8-69
RAM Drive Size, 8-66
Serial Port Protocol, 8-76
Resume Execution, 8-68
Start of Message (SOM), 8-78
Scan Ahead, 8-70
Stop Bits, 8-79
Scanner Mode, 8-71
Timeout Delay, 8-89
Scanner Redundancy, 8-72 Scanner Selection, 8-73 Scanner Timeout, 8-74 Scanner Trigger, 8-75 Suspend/Resume Control, 8-82 Time and Date, 8-87 Time in Seconds, 8-88
8-5
Page 154
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Entering Variable Data in a Configuration Command You can enter variable data for many of the configuration commands. For example, you can set a preamble that is up to 25 ASCII characters long. You need to follow these general instructions to enter variable data. To enter variable data in a configuration command
1. Scan a bar code label with this syntax: +/$+command where: +/ is the syntax for the Enter Accumulate Mode command.
$+ is the syntax for the Change Configuration command.
command is the syntax for the command you want to change.
For example, the command syntax for a preamble is ADdata. To change or set a preamble, scan this bar code: Enter Accumulate Mode / Change Configuration / Set Preamble
*+/$+AD* *+/$+AD*
2. Scan a bar code label from the “Full ASCII Bar Code Chart” in Appendix B. To set the preamble to the character T, scan this label: T
*T* *T*
Note: To use the bar code labels in Appendix B, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” later in this chapter. 3. Scan the Exit Accumulate Mode bar code label to update the terminal’s configuration: Exit Accumulate Mode
*-/* *-/*
8-6
Page 155
Nugg
Co d e
Configuration Command Reference 39
8
Append Time Purpose:
Appends the time to bar code labels when they are scanned into the terminal. You can also use the Time in Seconds command to append the time in hours and minutes only, or hours, minutes, and seconds. The time is appended to the data in the form HH:MM:SS. For help, see “Time in Seconds” later in this chapter.
Syntax:
DEdata Acceptable values for data are: 0 1
Default: Scan:
Disabled Enabled
Disabled One of these bar codes: Disable Append Time
*$+DE0* *$+DE0* Enable Append Time
*$+DE1* *$+DE1*
Automatic Shutoff Purpose:
Defines the maximum length of time the terminal remains on when there is no activity. When you do not use the terminal for the length of time set with this command, the terminal automatically turns off as if you had pressed to turn it off.
W
W
When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off or the terminal boots and restarts your application. Resume is controlled through the Resume Execution command. For help, see “Resume Execution” later in this chapter. Syntax:
EZdata Acceptable values for data are: 0 02-75
Disabled (always on) Shutoff time in minutes
8-7
Page 156
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d
Automatic Shutoff (continued)
Default: Scan:
0 (disabled) To disable automatic shutoff, scan this bar code: Disable Automatic Shutoff
*$+EZ0* *$+EZ0*
Or:
To set a timeout: 1. Scan this bar code: Enter Accumulate Mode / Set Automatic Shutoff
*+/$+EZ* *+/$+EZ*
2. Scan a numeric value for data from these bar codes:
*0*
*1*
*0*
*1*
*2*
*3*
*2*
*3*
*4*
*5*
*4*
*5*
*6*
*7*
*6*
*7*
*8*
*9*
*8*
*9*
3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
8-8 e
39
Page 157
Nugg
Co d e
Configuration Command Reference 39
8
Baud Rate Purpose:
Sets the baud rate for the serial port(s) on the terminal. The baud rate must match the baud rate of the device (i.e., the host computer) that the terminal is communicating with through the serial port.
Syntax:
YAn.data where n is: 1 2
COM1 serial port COM2 serial port
Acceptable values for data are: 3 4 5 6 7 8 Default: Scan:
1200 baud 2400 baud 4800 baud 9600 baud 19200 baud 38400 baud
19200 To set the default baud rate, scan one of these bar codes: Default Baud Rate for COM1
*$+YA1.7* *$+YA1.7* Default Baud Rate for COM2
*$+YA2.7* *$+YA2.7*
Or:
To set the baud rate: 1. Scan this bar code: Enter Accumulate Mode/Set Baud Rate
*+/$+YA* *+/$+YA*
8-9
Page 158
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Baud Rate (continued)
2. Scan one of these bar codes to set the COM port: COM1
COM2
*1.*
*2.*
*1.*
*2.*
3. Scan the baud rate: 1200 Baud
2400 Baud
*3*
*4*
*3*
*4*
4800 Baud
9600 Baud
*5*
*6*
*5*
*6*
19200 Baud
38400 Baud
*7*
*8*
*7*
*8*
4. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
Notes:
For COM1 only, you can use either command syntax listed next: Syntax:
YA1.data
Or:
IAdata where data is a value from 3 to 8 for the baud rate. For COM2, you must use the YA configuration command.
8-10
Page 159
Nugg
Co d e
Configuration Command Reference 39
8
Beep Volume Purpose:
Adjusts the volume of the terminal’s audio signals. For a list of all the beep sounds and audio signals, see “Understanding the Terminal’s Status Beeps” in Chapter 1. Set the beep and keyclick volume according to operator preference and work environment. Note: If the Beep Volume is turned off, you will not hear any audio signals including the keyclick.
Syntax:
BVdata Acceptable values for data are: 0 1 2 3 4 8 9
Default: Scan:
Off Quiet Normal Loud Very loud Lower volume Raise volume
Very loud One of these bar codes: Beep Volume Off
Beep Volume Quiet
*$+BV0*
*$+BV1*
*$+BV0*
*$+BV1*
Beep Volume Normal
Beep Volume Loud
*$+BV2*
*$+BV3*
*$+BV2*
*$+BV3*
Beep Volume Very Loud
*$+BV4* *$+BV4*
Or:
Scan one of these bar codes repeatedly to achieve the desired volume: Raise Beep Volume
Lower Beep Volume
*$+BV9*
*$+BV8*
*$+BV9*
*$+BV8*
8-11
Page 160
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugg
Co d e
39
Character Set Purpose:
Determines the language used to display characters.
Syntax:
DXdata Acceptable values for data are: 0 1 2 3 4 5 6 7
Default: Scan:
8-12
U.S. ASCII French German United Kingdom Danish Swedish Italian Spanish
U.S. ASCII One of these bar code labels: U.S. ASCII Character Set
French Character Set
*$+DX0*
*$+DX1*
*$+DX0*
*$+DX1*
German Character Set
United Kingdom Character Set
*$+DX2*
*$+DX3*
*$+DX2*
*$+DX3*
Danish Character Set
Swedish Character Set
*$+DX4*
*$+DX5*
*$+DX4*
*$+DX5*
Italian Character Set
Spanish Character Set
*$+DX6*
*$+DX7*
*$+DX6*
*$+DX7*