The text of a manual · part 12 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 111 to 120
Pages 111 to 120 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 111
Nugget
Co d e
Troubleshooting 39
6
Problems While Operating the Terminal (continued)
Problem
Solution
The terminal appears to be locked up and you cannot enter data.
Try these possible solutions: • (2461 only) Wait at least 10 seconds and try again. If the 2461 is still connecting to the DCS 300 or host, the 2461 ignores any input from the keyboard or input device. Make sure the Network Connect status light remains on before continuing. • Scan any bar code label to see if the terminal responds.
W
• Press to turn off the terminal. If it turns off, press terminal. You can continue working.
W to turn on the
• If the terminal will not turn off, reboot the terminal. Scan this bar code:
Boot Terminal
*-.1* *-.1* The system boots, clears RAM memory, and starts your application. • If the terminal will not boot or reset, contact your local Intermec service representative for help. The terminal is booting and you see a message that POST failed.
Report the error message to your supervisor. Press or scan Esc to exit the error message. Scan this bar code:
Boot Terminal
*-.1* *-.1* Your application appears on the screen. If the terminal still will not boot, contact your local Intermec service representative for help. The Power status light blinks.
The backup battery charge is low. Make sure that the power supply is connected to the terminal and a powered electrical outlet. Let the power supply charge the backup battery. The backup battery will be fully charged in approximately 24 hours. If the backup battery will not charge, you may need to replace it. For help, contact your local Intermec service representative.
6-5
Page 112
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Problems While Configuring the Ethernet Network You can configure the Ethernet network on the terminal by scanning configuration commands. If you receive an error beep sequence (three low beeps) while configuring the terminal, check these possible problems and solutions.
Problem
Solution
The terminal IP address or the controller/host IP address is set to 0.x.x.x or 127.x.x.x. These are invalid addresses.
Set a valid IP address for the terminal and DCS 300 or host.
The terminal IP address and the default router address are both set to the same address.
You need to change the terminal IP address and/or the default router address. Set a valid IP address for the terminal and the default router.
The terminal IP address and the controller/host IP address are both set to the same address.
Set a valid IP address for the terminal and DCS 300 or host.
The terminal and DCS 300 or host (TCP/IP network) are on different networks, and the terminal is not on the same network as the default router.
When the terminal is on a different IP subnetwork from the DCS 300 or host, you must set the Default Router and Subnet Mask commands. Set a valid IP address for terminal, DCS 300 or host, and default router.
On the 2461, you scan a configuration command to set one of these parameters and hear three low beeps:
If the Network Activate command is enabled (Ethernet network enabled) and you are configuring the 2461, these addresses must define a valid network configuration. For example, an invalid network configuration would be a controller (or host) IP address set to 0.0.0.0 with the network enabled.
• Controller IP Address or Host IP Address (TCP/IP) • Terminal IP Address • Default Router • Network Activate
To set these four parameters, follow these steps:
For help, see “Using Ethernet Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the DCS 300 or host.
For help, see “Using Ethernet Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each network device.
For help, see “Using Ethernet Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP address assigned to the terminal and the DCS 300 or host.
For help, see “Using Ethernet Communications on the Terminal” in Chapter 4. If you cannot fix the addressing problem, check with your network administrator to get the IP addresses for each network device.
1. Disable the Network Activate (NA) configuration command. 2. Set the terminal IP address and the controller IP address (or the host IP address for a TCP/IP network). 3. Set the default router address (if necessary). 4. Enable the Network Activate command. You can change an IP address with the network enabled as long as it still defines a valid network configuration.
6-6
Page 113
Nugget
Co d e
Troubleshooting 39
6
Problems While Configuring the Serial Network You can configure the serial network on the terminal by scanning configuration commands. If you receive an error beep sequence while configuring the terminal, check these possible problems and solutions. For help, see “Using Serial Communications on the Terminal” in Chapter 4.
Problem
Solution
The terminal is configured for Configurable protocol. You are scanning or entering a configuration command to set a serial port parameter and hear three low beeps. For example, you are trying to configure EOM, SOM, or Handshake.
The order in which you set serial port commands is important. Configurable Protocol uses EOM to determine the serial communications mode. When EOM is disabled, the terminal communicates in Character mode. When EOM is enabled, the terminal communicates in Frame mode. Follow these rules to configure the serial port for Configurable protocol.
You are configuring SOM and hear three low beeps.
You have configured SOM to an invalid value. SOM cannot equal the same value as EOM. You cannot set SOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM.
To use Frame mode, you need to set EOM first. Next configure Configuration Commands Via Serial Port, Handshake, LRC, SO, and then Poll. To use Character mode, you need to disable these same parameters in reverse order.
For help, see “Start of Message (SOM)” in Chapter 8. You are configuring EOM and hear three low beeps.
You have configured EOM to an invalid value. You cannot set EOM to any of these values: AFF (ACK), DLE, NEG (NAK), Poll, RES (EOT), REQ (ENQ), SEL, XOFF, or XON. You need to change the value of EOM or SOM. For help, see “End of Message (EOM)” in Chapter 8.
6-7
Page 114
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Problems While Scanning Configuration Commands You configure the terminal by scanning configuration commands. If you receive an error beep sequence while configuring the terminal, check these possible problems and solutions.
Problem
Solution
You receive the error beep sequence while scanning a configuration command.
Check the command you are trying to scan. Make sure the command is set correctly for the options and network communications you are using with the terminal. For help, see Chapter 8, “Configuration Command Reference.”
You scan a configuration command, such as Keypad Caps Lock, and nothing happens.
There are two possible solutions: • You may have one or more reader commands disabled, such as Change Configuration, so that you cannot change the configuration. Enable all of the reader commands and try again. • The terminal may be waiting for another command to complete the configuration change. If you started by scanning the Enter Accumulate command, you must finish the command by scanning the Exit Accumulate command. For help, see Chapter 8, “Configuration Command Reference.” Scan the Enable Override to temporarily enable all of the reader commands. When you are finished, remember to disable the override so that your data is not interpreted as a command.
Enable Override
*$+DC3* *$+DC3*
6-8
Page 115
Nugget
Co d e
Troubleshooting 39
6
2461 Will Not Communicate With Ethernet Network Devices If you cannot get the 2461 terminal to communicate with other devices in the Ethernet network, check these possible problems.
Problem
Solution
The Network Connect status light is not lit. The 2461 is not communicating with the Ethernet network.
You may need to enable the Network Activate command. Make sure the terminal is configured correctly to communicate in your network. For help, see “Configuring the 2461 Terminal” in Chapter 4.
The Network Connect status light blinks on the terminal screen.
In a UDP Plus network, the terminal is trying to establish communications with the DCS 300. You may need to configure the terminal to communicate with other devices in the Ethernet network. For help, see “Configuring the 2461 Terminal” in Chapter 4. You may also need to configure the server (UDP Plus) or host. Make sure the terminal is configured correctly and enabled. Make sure the server is turned on and data collection is started.
The Network Connect status light remains on, but the host computer is not receiving any data from the 2461.
There may be a problem with the connection between the DCS 300 and the host computer. Check with your network administrator or use the DCS 300 System Manual to troubleshoot any potential problems on the server. In a TCP/IP network, there may be a problem with the connection between the 2461 and the host computer. Check with your network administrator.
Problems Transmitting Data Through the Serial Port If you are having problems sending or receiving data through the serial port on the 246X terminal, check these possible problems: •
Make sure the terminal is connected to the host computer or serial device.
•
Make sure you are using a null-modem RS-232 cable to connect the serial device to COM1.
•
Make sure you are using the appropriate cable to connect the serial device to COM2.
•
Make sure the terminal’s serial port parameters are configured to match the serial port configuration on the host computer or serial device
For help connecting and configuring the serial port, see Chapter 2, “Installing the Terminal.”
6-9
Page 116
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Problems Transmitting Data Through the DCS 300 If you have a problem while running the application on the 2461 terminal in a UDP Plus network, check these possible communications problems.
Problem
Solution
Transaction Buffer Full.
The buffer holding transactions to be sent to the controller is full. Stop collecting data with this terminal. Make sure the terminal is communicating with the DCS 300 and let the terminal send all the transactions in the buffer before you continue collecting data.
Sending Buffer Transactions.
This is an information message to tell you that buffered transactions are now being sent to the DCS 300. You can begin collecting data again once the message clears.
Transaction Aborted.
The transaction just sent to the DCS 300 was not received. Try sending the transaction again.
Transmit Error XX, press Enter.
There is an error transmitting data to the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
W
Receive Error XX, press Enter.
There is an error receiving data from the DCS 300. XX represents the status code error. Note the error code listed in the message and contact your local Intermec service representative for help. Press to continue.
W
Shutting down.
The DCS 300 is shutting down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
Controller Shutdown.
The DCS 300 has shut down. You may continue collecting data and buffer the transactions in the terminal until the DCS 300 starts again, or stop collecting data with the terminal.
6-10
Page 117
Nugget
Co d e
Troubleshooting 39
6
Bar Code Labels Will Not Scan If you cannot scan bar code labels, check these possible problems.
Problem
Solution
The terminal is turned off.
Make sure the terminal is turned on. Press
An input device is not attached to the terminal.
Make sure an input device, such as a 1550 laser scanner, is attached correctly to the terminal. You must install an input device before scanning bar code labels.
The input device does not read the bar code labels quickly, or the scanning beam seems to be faint or obscured.
The input device, such as a 1550 laser scanner, window may be dirty. Clean the scanning window of the scan module with a solution of ammonia and water. Wipe dry. Do not allow abrasive material to touch the window.
You have an input device attached to the terminal and it cannot read any bar code labels.
You may not be using an input device that is supported by the 246X terminal. Make sure you are using one of the supported input devices:
W to turn on the terminal.
•
126X, 127X, and 128X wands
•
1354 and 1355 badge scanners
•
1517, 1518, 1519, and 1545 laser scanners
•
1550A, 1551A, 1550C, and 1551C laser scanners
•
1550B laser scanner with software version 1.9 or later
•
1551B laser scanner with software version 1.1 or later
•
1552 decoding laser scanner with 9745 base station
•
1463 CCD scanner
6-11
Page 118
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Bar Code Labels Will Not Scan (continued)
Problem
Solution
The input device will not read the bar code label.
Try one of these solutions: • Make sure you aim the scanner beam so it crosses the entire bar code label in one pass. • The angle you are scanning the bar code label may not be working well, or you may be scanning the label “straight on.” Try scanning the bar code label again, but vary the scanning angle. • The bar code label print quality may be poor or unreadable. To check the quality of the bar code label, try scanning a bar code label that you know scans. Compare the two bar code labels to see if the bar code quality is too low. You may need to replace the label that you cannot scan. • Make sure the bar code symbology you are scanning is enabled. If your bar code symbology is disabled, enable it and then try scanning the bar code label again. For help, see “Scanning Bar Codes to Enable Symbologies” in Chapter 3.
The input device does not appear to work well or read bar code labels very quickly.
6-12
Try setting the Scanner Selection command to the specific input device you have attached. Check the bar code symbologies you have enabled on the terminal. Enable only the symbologies that you are using.
Page 119
Nugget
Co d e
Troubleshooting 39
6
Booting and Resetting the Terminal You seldom need to boot or reset the 246X terminal. When you boot the terminal, it runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory. Once the terminal is finished booting, your application appears on the screen. You only need to reset the terminal when the terminal or an application are locked up and will not respond to any key sequences. The terminal also boots and resets after a firmware upgrade or if you remove both batteries. The next instructions explain how you boot and reset the terminal.
Booting the Terminal You can boot the terminal using these two methods:
W key to boot the terminal when you turn on the terminal.
•
Configure the
•
Use the Boot Terminal bar code.
Booting the Terminal on Resume
W W
When you press to turn off the terminal, it turns off and goes into Suspend mode. When you press to turn on the terminal, it resumes or boots depending on the terminal configuration. There are two ways to configure the configuration command:
W button using the Resume Execution
Resume Execution Not Allowed Configures the terminal to boot and restart your
W application each time you press to turn on the terminal. Use this option if you want to restart your application every time you turn on the terminal.
Resume Execution Allowed Configures the terminal to resume exactly where it was when you turned off the terminal. Use this option to resume working each time you turn on the terminal. You can configure the Resume Execution command by scanning these bar code labels. For help, see “Resume Execution” in Chapter 8.
Resume Execution Not Allowed
Resume Execution Allowed
*$+ER0*
*$+ER1*
*$+ER0*
*$+ER1*
6-13
Page 120
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Using the Boot Terminal Bar Code The terminal will boot after you scan this bar code:
Boot Terminal
*-.1* *-.1*
Resetting the Terminal If the terminal or application is locked up and the terminal will not respond to any key sequences, you can reset the terminal. Before you reset the terminal, try the following in order:
W to turn off the terminal.
•
Press
•
Scan the Reset Firmware label to restart the firmware and application.
Reset Firmware
*-.* *-.*
If the terminal or application still will not respond, boot the terminal.
6-14