The text of a manual · part 13 of 29
TRAKKER Antares 246X Stationary Terminal User's Manual, pages 121 to 130
Pages 121 to 130 of 290
The original document is the PDF (2.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2460 and Intermec 2461
Page 121
7 Reader Command Reference
Page 122
blank page
Page 123
nugget
39 Reader Command Reference
7
This chapter describes the reader commands that you can use while operating the terminal. Reader commands, such as Change Configuration, allow you to perform a task on the terminal.
Using Reader Commands A reader command causes the terminal to perform a task. Some reader commands temporarily override the configuration settings and some actually change the configuration settings. For example, you can reset the terminal to the default configuration or change the configuration. You can execute reader commands by • scanning a command from a Code 39 or Code 93 bar code label.
• sending a command from a device on the serial or Ethernet network.
There are three general types of reader commands: •
Accumulate mode commands
•
Operating commands
•
File management commands
The reader commands are listed in alphabetical order within these three categories. You will find the purpose, command syntax, and bar code labels for each reader command in this chapter. Note: The Code 39 bar code labels in this chapter show an asterisk (*) at the beginning and end of the human-readable interpretation to represent the start and stop codes. If you are creating your own Code 39 bar code labels, your bar code printing utility may automatically supply the asterisks as the start/stop code.
Using Accumulate Mode You can use Accumulate mode to collect data from a series of bar code labels and enter them as a single label. When you put the terminal in Accumulate mode, the terminal will collect all scanned bar code labels in the terminal’s buffer until you scan either the Enter or Exit Accumulate mode command. As you accumulate the data from bar code labels, the data is visible on the bottom line of the screen. You can edit the accumulated data with the Backspace, Clear, and Enter commands.
7-3
Page 124
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Backspace This command deletes the last character from the current data record you are accumulating.
Clear This command deletes the entire data record you are accumulating. Enter This command will enter data as a record and leaves the terminal in Accumulate mode. Note: If you are not in Accumulate mode, the Backspace, Clear, and Enter commands have no effect and you will hear a low beep. When you exit Accumulate mode, the accumulated data is “entered” as a data record. Up to 250 characters can be held in the buffer. If the data record count exceeds 250 characters, the data is truncated. If you reset the terminal (software or hardware reset), you exit Accumulate mode, the entire buffer is cleared, and all data accumulated is lost.
To use Accumulate mode The syntax to use the Enter Accumulate command is: +/data where: +/ is the syntax for the Enter Accumulate mode command.
data is the optional data you want to enter. Data can be a reader command that is executed when you exit Accumulate mode.
1. Scan this bar code label to Enter Accumulate mode: Enter Accumulate Mode
*+/* *+/*
2. Scan the bar code label(s) for the data you want to enter. You can scan labels from the “Full ASCII Bar Code Chart” in Appendix B. For example, scan this label to change the terminal’s configuration and set the preamble to the characters ABC. Change Configuration / Set Preamble to ABC
*$+ADABC* *$+ADABC*
7-4
Page 125
nugget
39 Reader Command Reference
7
Or, to edit the accumulated data, scan one of these bar code labels: Backspace
Clear
Enter
*-+*
*--*
**
*-+*
*- -*
**
Note: You can create one bar code label by combining Steps 1 and 2 above. Most of the examples in this manual use one bar code label. 3. Scan this bar code label to exit Accumulate mode and enter the data record. Exit Accumulate Mode
*-/* *-/*
Enter Accumulate Mode Purpose: From Network: Scan:
Enters Accumulate mode. You can accumulate data from a series of bar code labels and enter them as a single label. Not supported Enter Accumulate Mode
*+/* *+/*
Backspace Purpose:
From Network: Scan:
Deletes the last character from the current data record being accumulated. If there is no data in the buffer, the command has no effect. Not supported Backspace
*-+* *-+*
7-5
Page 126
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Clear Purpose: From Network: Scan:
Deletes the entire data record you are accumulating. If there is no data in the buffer, the command has no effect. Not supported Clear
*--* *- -*
Enter Purpose:
From Network: Scan:
Enters the current data record and remains in Accumulate mode. If no data exists, a null string is entered. Not supported Enter
** **
Exit Accumulate Mode Purpose:
From Network: Scan:
Exits Accumulate mode and transmits the current data record. If no data has been accumulated, an empty data record is entered. Not supported Exit Accumulate Mode
*-/* *-/*
7-6
Page 127
nugget
39 Reader Command Reference
7
Operating Reader Commands The reader commands you can use to operate or change the terminal’s configuration are listed in this section. The operating commands are listed in alphabetical order. You will find these reader commands detailed in this section: •
Boot Terminal
•
Change Configuration
•
Default Configuration
•
Multiple-Read Labels
•
Reset Firmware
•
Save Configuration in Flash Memory
•
Scanner Trigger On and Off
•
Set Time and Date
•
Status Lights Control
Boot Terminal Purpose:
Boots the terminal. The terminal runs through power-on self test (POST) to test each major subsystem. The terminal uses the configuration currently saved in flash memory to boot and then your application appears on the screen. Use this command when you upgrade the firmware on the terminal or if your terminal locks up and will not respond.
From Network: Scan:
-.1 Boot Terminal
*-.1* *-.1*
7-7
Page 128
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Change Configuration Purpose:
From Network:
This command must precede any configuration command. If you enter a valid string, the terminal configuration is modified and the terminal sounds a high beep. $+command[command]...[command n] where command is a configuration command with the value you want to set.
Example:
Change Configuration / Turn Off Beep Volume
*$+BV0* *$+BV0*
The Change Configuration command is followed by the configuration command to turn off the beep volume (BV0).
Default Configuration Purpose:
Sets the terminal to its default configuration, resets the firmware, boots the terminal, and runs your application. The default configuration for the terminal is listed in Appendix A. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3. When you use the Default Configuration command, the default configuration is saved in RAM and flash memory. The runtime and boot configuration are changed to the default configuration. Note: In the default configuration, the Network parameters are set to the default values. The 2461 terminal will no longer have a valid IP address and cannot communicate with other devices. You need to configure the 2461 terminal again. For help, see Chapter 4, “Operating the Terminal in a Network.”
From Network: Scan:
.+0 Default Configuration
*.+0* *.+0*
7-8
Page 129
nugget
39 Reader Command Reference
7
Multiple-Read Labels Purpose:
A multiple-read label is a Code 39 or Code 93 bar code label that has a space as the first character after the start code. The terminal stores a multiple-read label in the buffer until you execute a command to transmit the label or scan a regular label. A regular bar code label is executed as soon as you scan it. If you use a configuration command to disable multiple-read labels, the terminal processes the bar code label as a regular label and reads and decodes the space as data.
From Network: Label Syntax:
Not supported <Start Code><SP>data<Stop Code> where <SP> is the ASCII space character and data is the content of the label.
Example:
Multiple-Read Bar Code Label
* A* * A*
After you scan a multiple-read bar code label, the accumulated data appears on the bottom line of the terminal screen. You can use the Accumulate mode commands, such as Backspace or Clear, to accumulate data. Once you scan a non-multiple-read label, the data is entered.
Reset Firmware Purpose:
From Network: Scan:
Resets all firmware on the terminal, resets the application, and runs the application. You can use the Reset command to restart your application if you are having problems. -. Reset Firmware
*-.* *-.*
7-9
Page 130
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Save Configuration in Flash Memory Purpose:
From Network: Scan:
Saves the current runtime terminal configuration in flash memory. If you configure the terminal by scanning bar code labels or sending commands from a network device, your configuration changes are only saved in RAM. You can use this reader command to save the changes to flash memory so that they are set the next time you boot or reset the terminal. .+1 Save Configuration in Flash Memory
*.+1* *.+1*
Scanner Trigger On and Off The Scanner Trigger On and Off commands are the same as pulling and releasing the scanner trigger. This command is valid on a 246X terminal only when you have an Intermec 1545 laser scanner attached to the scanner connector. After a Scanner Trigger On command, the scanner operates differently depending on the Scanner mode and scanner trigger configuration settings: •
If you configure the terminal to use One-Shot Scanner mode and level triggering, the scanner automatically turns off after a good read of a bar code label, or after the scanner timeout period elapses.
•
If you configure the terminal to use Automatic Scanner mode and level triggering, the scanner remains on after a good read of a bar code label. You can use the Scanner Trigger Off command to turn off the scanner, or set the Scanner Timeout command to automatically turn off the scanner after it stays on for the period of time set.
For help on configuring the Scanner Mode or Scanner Trigger commands, see Chapter 8, “Configuration Command Reference.” Note: Intermec does not recommend that you use a Scanner Trigger On or Off command with the Scanner Trigger command set to edge triggering. Purpose:
From Network: Scan:
7-10
The Scanner Trigger On command is the same as pulling the trigger on the 1545 laser scanner. /. Not supported