nugget
39 Programming the Terminal
5
Restore User Files Dialog Box
5. In the Available Files list box, add all the files that you want to restore to the Selected Files list box. a. Select the file name. b. Choose Select. The file name appears in the Selected Files list box.
If the Selected Files list box shows any files that you do not want to restore, select the file name and choose Remove. 6. Choose Restore Files. The DCS 300 restores the files you selected to the USERDATA directory. 7. Remove your disk from the disk drive.
5-13
Page 102
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Downloading Applications and Files to the 2461 Once the applications and files are stored on the DCS 300, you can download applications and files to a 2461 running UDP Plus. There are two ways to download files: •
Use the Download Server feature on the server.
•
Use the Receive File or Transmit File reader commands. For help, see Chapter 7, “Reader Command Reference.”
The instructions in this section explain how to use the Download Server feature on the server to download applications and files to the terminal. To prepare the terminal
•
Make sure the terminal is on and communicating with the server. Look at the status lights on the left side of the terminal’s front panel. If the Network Connect status light is turned on, the terminal is communicating with the server. For help, see Chapter 6, “Troubleshooting.”
To download applications and files to the 2461
1. If data collection is not started on the DCS 300, choose Start Data Collection from the main menu sidebar buttons. 2. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 3. In the System Maintenance dialog box, select Configure Download Server and then choose Start. The Terminal Download Configuration dialog box appears.
5-14
Page 103
nugget
39 Programming the Terminal
5
4. From the Terminal Download Configuration dialog box in the Terminals and Groups list box, select a terminal or group of terminals to receive the binary applications and files. For help defining a group of terminals, see “Adding a Group in the Download Server” in Appendix C of the DCS 300 System Manual. 5. Choose Edit. The Configure Device Initialization Download dialog box appears.
6. Verify that there are no files (or entries) listed in the Files and Data list box. If there are entries, then choose Clear to remove them. 7. In the Initialization Data box, choose File. 8. In the field, type: \filename where filename is the name of the executable binary application. Or choose Find, select your application, and choose OK. 9. Enable the Binary file check box. 10. Enable the Overwrite option button to overwrite an existing file with the same name. 11. In the Target file name field, type a name if you want to save the file under a different name on the terminal. Do NOT enter a slash or backslash character before the target filename. 12. Choose Add. The file appears in the Files and Data list box with a B for binary in the leftmost column.
5-15
Page 104
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
Configure Device Initialization Download Dialog Box
13. Repeat Steps 7 through 12 to select another application. 14. You can also download files used by your application such as an employee list or a part number list. To download additional files, choose File in the Initialization Data box. Type in the filename including the backslash. Disable the Binary file check box and then choose Add. 15. To run an application on the 246X, choose Command in the Initialization Data box. Enter the Run Program reader command and choose Add. The command appears in the Files and Data box. For example, to run the application SHIPPING.BIN, enter this command: //c:shipping.bin 16. Choose OK to save your changes and return to the Terminal Download Configuration dialog box. 17. In the Terminals and Groups list box, choose the terminal or group you configured if it is not already highlighted and marked with an asterisk. 18. Choose Download. A Download initiated message box appears. 19. Choose OK. The executable binary applications and files are downloaded to the terminal or group of terminals usually within a few seconds. If you are downloading the applications and files to many terminals, the download may take longer. All files are downloaded and stored on the terminal’s flash drive C.
5-16
Page 105
nugget
39 Programming the Terminal
5
If you downloaded the command to run an application, the terminal boots, resets, and runs the application. For help running an application, see “Run Program” in Chapter 7. If you have problems downloading files, see Chapter 6, “Troubleshooting.”
Troubleshooting Applications Once you download a new application to the terminal, you are ready to test it before you start collecting data. If the terminal or application appears to be locked up and you cannot enter data, try these steps in order. To troubleshoot a locked-up terminal or application
W
1. Press to turn off the terminal. If it turns off, press You can continue working.
W to turn on the terminal.
2. Scan the Reset Firmware label to restart the firmware and application.
Reset Firmware
*-.* *-.*
You can also send the Reset Firmware command over the network. For help, see Chapter 7, “Reader Command Reference.” 3. Scan a bar code to configure the Resume Execution command to resume “not allowed.” See the “Resume Execution” command in Chapter 8. Each time you press to turn on the terminal, the terminal boots and restarts your application.
W
4. If your terminal appears to boot but the application will not run or is locked up, press and hold the Tab key immediately after you scan the Reset Firmware label or after you press to turn on the terminal. Continue to hold the Tab until you hear a click and the screen clears.
W
The terminal has booted without loading an application. Load and run another application or download a new version of the application before you run it again. 5. If the terminal will not turn off or does not respond to the Reset Firmware command, boot the terminal. Make sure you have tried Steps 1 and 2 before you boot the terminal. a. Press step.
W to turn off the terminal. If it will not turn off, continue with the next b. Scan this bar code:
Boot Terminal
*-.1* *-.1*
5-17
Page 106
TRAKKER Antares 246X Stationary Terminal User’s Manual nugget
39
6. If the terminal will not boot, try loading the firmware. For help, see “Upgrading the Firmware” in Chapter 3. If the terminal will not boot or reset, contact your local Intermec service representative for help.
5-18
Page 107
6 Troubleshooting
Page 108
blank page
Page 109
Nugget
Co d e
Troubleshooting 39
6
This chapter lists the problems you may have while using the terminal and gives some possible solutions. You will also find instructions that explain how to boot and reset the terminal.
Finding and Solving Problems If you have a problem while configuring or using the terminal, use the tables in this section to find a solution. For easy reference, problems are grouped into these topics: •
Problems While Operating the Terminal
•
Problems While Configuring the Ethernet Network
•
Problems While Configuring the Serial Network
•
Problems While Scanning Configuration Commands
•
2461 Will Not Communicate With Ethernet Network Devices
•
Problems Transmitting Data Through the Serial Port
•
Problems Transmitting Data Through the DCS 300
•
Bar Code Labels Will Not Scan
Caution There are no user-serviceable parts inside the terminal. Opening the unit will void the warranty and may cause damage to the internal components. Conseil La terminal ne contient pas de pièces révisibles par l’utilisateur. Le fait d’ouvrir l’unité annule la garantie et peut endommager les pièces internes. If you send the terminal in for service, it is your responsibility to save the terminal data and configuration. Intermec is responsible only for ensuring that hardware features match the original configuration when repairing or replacing your terminal.
6-3
Page 110
TRAKKER Antares 246X Stationary Terminal User’s Manual Nugget
Co d e
39
Problems While Operating the Terminal If you are operating the 246X terminal and have trouble, check these possible problems and solutions.
Problem
W
Solution
You press to turn on the 246X terminal and nothing happens.
Make sure that you have plugged the power cable into the terminal and the outlet. For help, see Chapter 2, “Installing the Terminal.” Replace the power cable if damaged.
You scan a reader command, such as Change Configuration, and nothing happens.
The reader commands are disabled. Scan the Enable Override command shown here to temporarily enable all of the reader commands. For help, see “Command Processing” in Chapter 8. When you are finished, remember to disable the override so that your data is not interpreted as a command.
Enable Override
*$+DC3* *$+DC3* You scan a valid bar code label to enter data for your application. The data decoded by the input device does not match the data encoded in the bar code label.
The terminal may have decoded the bar code label in a symbology other than the label’s actual symbology. Try scanning the bar code label again. Make sure you scan the entire label.
You want to set the terminal back to the default configuration to start over configuring the terminal.
Scan this bar code label:
To operate the terminal quickly and efficiently, you should enable only the bar code symbologies that you are going to scan. If you enable multiple symbologies, the terminal may on rare occasions decode a bar code according to the wrong symbology and produce incorrect results.
Default Configuration
*.+* *.+*
Note: After you load the default configuration, you may need to set the network communications parameters on a 2461 to communicate with other devices in the Ethernet network.
6-4