The text of a manual · part 8 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 71 to 80
Pages 71 to 80 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 71
CODE39 Nugget Installing the Terminal
UDP Plus Primary Network
TCP/IP Primary Network
PRIMARY NETWORK
PRIMARY NETWORK
Activate: Disabled Controller IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
Activate: Disabled Host IP Addr: 0.0.0.0 Terminal IP Address: 0.0.0.0
OK
CANCEL
2
OK
CANCEL 2455U.049
W
6. Press to set the Network Activate command to 2.4 GHz RF. Press the next field.
V to move to
Enter the Controller IP address for a UDP Plus network. Enter the Host IP address for a TCP/IP network. Enter the Terminal IP address. IP address fields consist of four separate numbers. Each number in the field is separated by a period and can be a number from 0 to 255. Type the address in the format nnn.nnn.nnn.nnn and then press .
V
For example, if your terminal IP address is 192.100.100.3, type:
Note: The network cannot be activated if the first address segment in the IP address is set to 0, 127, or a number greater than 223.
to save the changes and exit the Primary Network screen. 8. Press V to choose the Radio command and then press The Radio screen 7. Press appears.
UDP Plus and TCP/IP Radio RADIO Domain: 00 Security ID: (ID unchanged) Wakeup on Broadcast: No Roam Flag: Allowed Transmit Mode: BFSK Inactivity Timeout: 5 sec OK
CANCEL 2455U.050
2-21
Page 72
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
V . The domain In the Security ID field, type the RF security identification and then press V . The
9. In the Domain field, type a number from 0 to 15 and then press must match the number set on the access point.
Security ID is case-sensitive and can be up to 20 characters long. It must match the security ID set on the access point. Press to save the changes and exit the Radio screen.
Note: If the terminal is on a different IP subnetwork from the DCS 300, controller, or host, you must also configure the default router and subnet mask. Choose the Advanced Network command to set these parameters. For help, see Chapter 4, “Operating the Terminal in a Network.”
:
10. For TCP/IP networks, press to choose the Advanced Network command and then press . The Advanced Network screen appears. UDP Plus Advanced Network ADVANCED NETWORK Loopback: Disabled Network Port: 05555 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 Controllr Connect Chk Send Timer:0035 sec Recv Timer:0060 sec Retries: 07
TCP/IP Advanced Network ADVANCED NETWORK Network Port: 00023 Subnet Mask: 255.255.255.0 Default Router: 0.0.0.0 TCP/IP Maximum Transmit Timeout: 020 sec
OK
CANCEL
` more 2455U.051
11. In the Network Port field, type a number from 1 to 65535 and then press . The default value is 23, which enables VT/ANSI Telnet communications. If you are not using Telnet communications, enter the port number used by your application. Note: For UDP Plus networks, the Network Port default is 5555, which matches the default value set on the DCS 300 and controller.
] to exit the Communications Menu. The Configuration Menu appears. 13. Press ] to exit the Configuration Menu. 14. Press to choose Yes and save the new configuration in RAM. Once the 12. Press changes are saved, the terminal uses the new configuration.
2-22
Page 73
CODE39 Nugget Installing the Terminal
2
Saving Configuration Changes in RAM Screen
Save new configuration (in
RAM)?
Yes
No
CANCEL
2455U.053
] to exit the TRAKKER Antares 2400 Menu System. 16. Press to choose Yes and store your changes permanently in flash memory. 17. Press to choose OK and exit the TRAKKER Antares 2400 Menu System. The 15. Press terminal tries to establish communications with the DCS 300, the controller, or the host.
For terminal emulation applications in a UDP Plus network, you need to configure the host name in the TE Configuration menu to establish communications. For help, see the TRAKKER Antares Terminal Emulation User’s Guide. Once the terminal connects, the login or initial screen for your application appears and the Connect status light remains on. You can begin using the terminal to collect data. Follow the instructions in the section, “Starting the Application and Using the Terminal” later in this chapter. Note: While the terminal is connecting to the DCS 300, controller, or host, the terminal ignores any input from the keypad, keyboard, or scanner. Wait until the terminal is connected before you try to enter any data.
Configuring the Serial Port Parameters You use the terminal serial ports to transfer data between the terminal and a serial device, such as a printer, scale, or PC. The terminal has two serial ports (COM1 and COM4) that support RS-232 communications. For help connecting a serial device to each COM port, see “Connecting to Serial Devices” earlier in this chapter. You must first select the communications protocol for the COM port. Depending on the protocol, you need to set some or all of these serial port parameters to have the terminal communicate with a serial device:
2-23
Page 74
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Serial Port Parameters Parameter
Default Value
Baud rate
19200
Commands via serial port
Enabled without TMF
Data bits
7
EOM (End of Message)
\x03 (hexadecimal ASCII value for ETX)
Flow control
None
Handshake
Disabled
LRC
Disabled
Parity
Even
Poll (Polling)
Disabled
Serial Port Protocol
Configurable
SOM (Start of Message)
\x02 (hexadecimal ASCII value for STX)
Stop bits
1
Timeout delay
10 seconds
The values you set for the terminal serial port must match the values set for the device’s serial port. You use the TRAKKER Antares 2400 Menu System to set the parameters on the terminal. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” To set the serial port parameters 1. From the Main Menu, choose the Configuration Menu and then press Configuration Menu appears.
The
Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.
CONFIGURATION
MENU
Symbologies Menu Communications Menu Terminal Menu
⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.054
2-24
Page 75
CODE39 Nugget Installing the Terminal
V
2. Press to choose the Communications Menu and then press Communications Menu appears.
2
The
COMMUNICATIONS MENU Primary Network Advanced Network Radio Serial Port [COM1] Serial Port [COM4]
⁄ _` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.055
3. Choose COM1 or COM4 and press
SERIAL PORT [COM1]
One of these Serial Port screens appears. SERIAL PORT [COM4]
Protocol: Configurable Baud Rate: 19200 Parity: Even Data Bits: 7 Stop Bits: 1
Scanner Port: Scanner Enabled Protocol: Configurable Baud Rate:19200 Parity: Even Data Bits: 7 Stop Bits: 1
` more
` more
2455U.200
V
W
4. To configure COM4, you must first set the Scanner Port field. Press to toggle through the options and select one of the RS-232 values. Press to move to the next field. For help, see “Scanner Port (COM4)” in Chapter 9. 5. You must next select the protocol for the COM port. When you select a protocol, the serial port parameters screen changes to display the parameters that you can set for each protocol. Select one of these protocols: • • • •
Configurable Polling Mode D Master Polling Binary
2-25
Page 76
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
W
V
Press to toggle through the protocol options and select a value. Press to move to the next field. For more information about protocols, see Chapter 4, “Operating the Terminal in a Network.”
W
V
6. In each field, press to toggle through the field options and select a value. Once the correct value is displayed, press to move to the next field. Or, enter a value in the field. You must set each of the terminal serial port parameters to match your serial device settings. Once they match, you can communicate through the terminal serial port.
8. Press ] until you exit the menus. 9. Press to choose Yes and save the new configuration in RAM. Once the changes are saved, the terminal uses the new configuration. 10. Press ] to exit the TRAKKER Antares 2400 Menu System. 11. Press to choose Yes and store your changes permanently in flash memory. 12. Press to choose OK and exit the TRAKKER Antares 2400 Menu System.
7. Press to save the changes and exit the Serial Port screen. The Communications Menu appears.
Starting the Application and Using the Terminal Your T2455 ships loaded with one of these applications: •
Sample application
•
Terminal emulation application (IBM 3270, IBM 5250, or VT/ANSI)
To start the application and use the terminal f
1. Press to turn on the terminal. The login or initial screen for your application appears. 2. Check the three application screens shown next in the left column. Find the application screen that matches the one on your terminal. Follow the instructions on the right of the screen to use the terminal.
2-26
Page 77
CODE39 Nugget Installing the Terminal
2
Sample Application Screen 1998/01/08
08:10:50 a. Use the sample application to scan bar code labels and test the keyboard. b. (Optional) Connect the T2455 to a host computer using the COM1 port connector. For help, see “Installing the Terminal and Connecting Devices” earlier in this chapter.
2455U.057 c. Download your data collection application to the terminal either through the serial port or from the DCS 300, Model 200 Controller, or host and run it. For help, see Chapter 5, “Using Custom Applications.”
3270/5250 TE Sign-On Screen Sign on User.............. Password.......... Program/procedure. Menu.............. Current Library...
a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide. b. Log in to a terminal emulation session. c. Start using the terminal to collect and transmit data.
2455U.058
VT/ANSI TE Login Screen a. Configure the terminal emulation application (if necessary). For help, see the TRAKKER Antares Terminal Emulation User’s Guide.
<login: F b. Log in to a terminal emulation session. c. Start using the terminal to collect and transmit data. 2455U.059
2-27
Page 78
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Turning the Terminal On and Off f
The Suspend/Resume key is the f key on the right side of the function keypad.
When you press to turn off the terminal, the terminal does not actually shut off, but goes into a Suspend mode. This mode is referred to as “off” in the rest of this manual. In Suspend mode, the terminal continues to power all memory and turns off the power to most of the hardware.
f
When you press to turn on the terminal, the terminal either resumes exactly where it was when you turned it off, or the terminal boots and restarts your application. Resume is controlled through a parameter or command called Resume Execution. By default, the terminal resumes your application. For help, see “Resume Execution” in Chapter 9.
ff f
You can configure the terminal to disable the key. When the key is disabled, you cannot turn off the terminal. By default, the key is enabled so you can turn the terminal on and off. For help, see “Suspend/Resume Control” in Chapter 9.
Using the Desktop Mounting Stand The desktop mounting stand provides a stable platform if you want to connect the terminal to your PC to develop applications. Use the AC power supply (Part No. 065236) and AC power supply adapter cable (Part No. 066842) to power the terminal when it is in the desktop mounting stand. Note: The AC power supply is only for use in clean, dry office-like environments with temperatures from 50°F to 104°F (10°C to 40°C). On a T2455 with the coldtemperature option, the heaters are designed to operate the terminal below this range, but only by using a DC power supply. To use the desktop mounting stand 1. Attach the mounting bracket to the desktop mounting stand using the hardware that shipped with the stand. For help, see the T2455 Desktop Mounting Stand Instruction Sheet (Part No. 067361). 2. Attach the T2455 to the mounting bracket. For help, see “Installing the T2455 in the Mounting Bracket” earlier in this chapter.
2-28
Page 79
CODE39 Nugget Installing the Terminal
2
Using the Desktop Mounting Stand
2455U.062
3. Unplug the rubber plug from the Power Supply port on the terminal. 4. Insert the AC power supply adapter cable connector straight into the Power Supply port on the terminal. The icon on the AC power cable connector should align with the same icon on the back of the T2455. Note: Firmly push the AC power cable connector straight into the Power Supply port. If the connector doesn’t fit, do not force it. Do not wiggle or twist the power cable connector - you may damage the connector.
Power cable connector
2455U.064
Note: The Power Supply port plug is not shown for clarity.
2-29
Page 80
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
5. Use a small straight-slot screwdriver to tighten the two screws in the AC power cable connector and secure the cable to the T2455. 6. Attach the other end of the AC power cable to the AC power supply. Next, connect the power cord from the AC power supply to a powered electrical outlet.
Using Input Devices You use bar code input devices that are connected to the TRAKKER Antares 2455 terminal to scan and enter bar code data. The terminal decodes the bar code label and enters the data or command you scanned. The T2455 has one Scanner port to connect an external scanner. When you unpack the T2455 and use it, only three bar code symbologies are enabled: •
Code 39
•
Code 128
•
UPC/EAN
If you are using bar code labels that are encoded in another symbology, you need to enable that symbology on the terminal. For help, see “Scanning Bar Codes to Enable Symbologies” in Chapter 3, or find the symbology in Chapter 9, “Configuration Command Reference.”
Using a Laser Scanner You can attach a laser scanner to the Scanner port on the terminal. Since the Scanner port is a keyed connector, you must use one of the accessory scanner cables to connect an input device. You can use these Intermec scanners with the T2455: •
1517, 1518, 1519 laser scanners
•
1550 and 1551 laser scanners
•
1552 cordless laser scanner with 9745 base station
Once you have the scanner attached, you can use the scanning options that are described in the next section to customize bar code input. You may also need to configure the Scanner Selection command to identify the type of scanner. The terminal can optimize the scanning performance by using the scanner you define in the Scanner Selection command. For help, see “Scanner Selection” in Chapter 9.
2-30