The text of a manual · part 7 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 61 to 70
Pages 61 to 70 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 61
CODE39 Nugget Installing the Terminal
2
7. Periodically inspect the knob on the mounting bracket to make sure they are still tight. Check the mounting bracket for any signs of fatigue, such as cracking, which might develop over extended use in extreme (vibration) environments. Replace any damaged hardware immediately to ensure continued, safe operation.
Installing and Connecting the DC Power Supply You need to install the DC power supply and connect the power supply to the vehicle battery and to the T2455. You need one of these DC power supply kits: •
Low-input voltage kit (10 to 36 VDC) (Part No. 067698)
•
High-input voltage kit (15 to 96 VDC) (Part No. 067699)
This illustration shows how the DC power supply and cables are installed with your vehicle battery and the T2455. Fused power cable
DC power supply
Power supply input cable
+
T2455 power cable
-
Vehicle battery
2455U.037
T2455
To install and connect the DC power supply 1. Disconnect the vehicle battery cables. 2. (Optional) Wire or add a remote disconnect for the DC power supply on combustion-powered vehicles that have smaller capacity batteries. 3. Connect the fused power cable to the vehicle battery or terminal block. 4. Mount the DC power supply. 5. Connect the power supply input cable to the power supply. 6. Install terminators on the power supply input cable.
2-11
Page 62
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
7. Attach the power supply input cable to the fused power cable. 8. Attach the T2455 power cable to the power supply and to the terminal. 9. Reconnect the vehicle battery cables. For detailed instructions on installing the DC power supply, see the TRAKKER Antares 2455 DC Power Supply Installation Guide (Part No. 067362).
Attaching a Scanner You can attach a laser scanner to scan and input bar code data. Use the accessory laser scanner cables to connect a scanner. For help ordering the appropriate laser scanner cable, see Appendix A, “Terminal Specifications.” To attach a scanner 1. Unplug the rubber plug from the Scanner port on the terminal. 2. Insert the scanner cable connector straight into the Scanner port on the terminal. The icon on the scanner cable connector should align with the same icon on the back of the T2455. Note: Firmly push the scanner cable connector straight into the Scanner port. If the connector doesn’t fit, do not force it. Do not wiggle or twist the scanner cable connector - you may damage the connector.
Scanner cable connector
2455U.038
Note: The Scanner port plug is not shown for clarity.
2-12
Page 63
CODE39 Nugget Installing the Terminal
2
3. Use a small straight-slot screwdriver to tighten the two screws in the scanner cable connector and secure the cable to the T2455. 4. Attach the other end of the scanner cable to your scanner. 5. Make sure the cable will not be pinched or rubbed by any moving parts on the vehicle.
Connecting to Serial Devices You use the terminal’s serial ports to transfer data between the terminal and a serial device using RS-232 communications. The terminal has a dedicated serial port (COM1). A second serial port is available if you configure the Scanner port as COM4. You need to use an adapter cable to connect a serial device such as a PC, scale, or printer to COM1 and COM4: •
For COM1, you can use one of the adapter cables listed in “Cable Accessories” in Appendix A.
•
For COM4, you must use the COM Port Adapter Cable (Part No. 061799).
The next two procedures describe how to connect a serial device to COM1 and COM4. To connect a serial device to COM1 1. Unplug the rubber plug from the COM1 port on the terminal. 2. Insert the RS-232 adapter cable connector straight into the COM1 port on the terminal. The icon on the RS-232 adapter cable connector should align with the same icon on the back of the T2455. Note: Firmly push the RS-232 adapter cable connector straight into the COM1 port. If the connector doesn’t fit, do not force it. Do not wiggle or twist the RS-232 adapter cable connector - you may damage the connector.
2-13
Page 64
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Connecting a Serial Device to COM1
RS-232 adapter cable connector
2455U.039
Note: The COM1 port plug is not shown for clarity. 3. Use a small straight-slot screwdriver to tighten the two screws in the RS-232 adapter cable connector and secure the cable to the T2455. 4. Attach the other end of the RS-232 adapter cable to the 9-pin RS-232 connector on your serial device. 5. Make sure the cable will not be pinched or rubbed by any moving parts on the vehicle. To connect a serial device to COM4 1. Unplug the rubber plug from the Scanner port on the terminal. 2. Insert the COM port adapter cable (Part No. 061799) connector into the Scanner port on the terminal. Note: This cable does not provide an environmentally sealed connection to the T2455. 3. Attach the other end of the COM port adapter cable to the 9-pin RS-232 connector on your serial device. 4. Make sure the cable will not be pinched or rubbed by any moving parts on the vehicle. 5. Configure the Scanner Port as COM4. For instructions, see “Scanner Port (COM4)” in Chapter 9.
2-14
Page 65
CODE39 Nugget Installing the Terminal
2
Charging the Backup Battery The backup battery backs up all memory and the real-time clock in case of a power failure. The backup battery is shipped inside the terminal, but may not be fully charged. You need to fully charge the backup battery. You can operate the terminal while the backup battery is charging. For more information about the backup battery, see “Backup Battery” in Chapter 1. Note: To guarantee data retention, you need to fully charge the backup battery after you first install the terminal and before you use the terminal for the first time. To charge the backup battery 1. Make sure the terminal is connected to an external power supply. The terminal must be connected to either the DC power supply that is connected to the vehicle battery or the terminal must be connected to the AC power supply and a powered electrical outlet. 2. Let the power supply charge the backup battery for 14 hours to fully charge the backup battery.
Turning On the Terminal for the First Time Once the power supply is connected and you have installed the terminal, you are ready to turn on the terminal.
f
To turn on the terminal 1. Press the key on the function keypad. The terminal runs POST (power-on self test) and then the Boot Menu appears.
BOOT
MENU
F1
-
Boot
F2
-
Run
F3
-
Power
POWER
DOWN
System Loader
IN
Down
60
SEC 2455U.040
2-15
Page 66
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
] ^
Note: If the backup battery charge is low and the terminal fails POST, a POST results screen appears. If the backup battery is the only failed test, press or to exit the screen. If any other test failed, contact your local service representative before using the terminal.
b
2. Press to boot the terminal and initialize the firmware. The TRAKKER Antares screen appears.
VERSION 4.XX COPYRIGHT 1996-1998
2455U.042
Next, either a sample application screen or a terminal emulation (TE) application welcome screen appears. For example:
1996/01/01
12:00:00
Intermec TRAKKER Antares 3270 Terminal Emulation Version 5.X
2455U.043
Note: On a T2455 loaded with terminal emulation, you may need to press create the TE configuration file.
to
3. Configure the RF or serial communications parameters so that you can begin using the terminal. Follow the instructions for “Configuring the Terminal to Communicate in Your Network” in the next section.
2-16
Page 67
CODE39 Nugget Installing the Terminal
2
Configuring the Terminal to Communicate in Your Network You need to configure the T2455 to communicate with RF or serial devices in your network. Here are the parameters you need to set: •
Time and Date
•
RF communications
•
Serial port (COM1)
The next sections list the parameters you need to configure and explain how to use the TRAKKER Antares 2400 Menu System to configure the terminal.
Setting the Time and Date You need to set the time and date on the terminal so that all transactions are correctly date and timestamped. To set the time and date or scan this bar code to access the TRAKKER Antares
1. Press 2400 Menu System:
Enter Test and Service Mode
*..-.* *..-.*
The Main Menu appears.
2455U.044
V
2. Press to choose the System Menu and then press appears.
The System Menu
2-17
Page 68
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
System Menu SYSTEM MENU File Manager Load Default Values Set Time and Date Store Configuration Upgrade Firmware ⁄
_` Select item [Enter] Next screen [F1] Help [Esc] Exit 2455U.046
V
3. Press to choose the Set Time and Date command and then press and Date screen appears.
TIME
AND
The Time
DATE
Current time 12:00:00 New time: 12:39:00 is
Current date is 1996/01/01 New date YYYY/MM/DD:
OK
CANCEL 2455U.047
V
4. Type the current time in the format HH MM SS (hours, minutes, seconds) with a space character ( ) between each field and then press . The program fills in the colon character in the time field. For example, to enter the time 04:05:03 P.M., type:
V
Note: The time is not actually updated until you exit the Time and Date screen. When you set the time, set the time ahead so that the correct time is saved when you exit the screen in Step 6.
V
5. Type the current date in the format YYYY MM DD (year, month, day) with a space character ( ) between each field and then press . The program fills in the slash character in the date field.
2-18
Page 69
CODE39 Nugget Installing the Terminal
2
For example, to enter the date August 9, 1998, type:
V 6. Press to save the changes and exit the Time and Date screen. 7. Press ] to exit the System Menu. The Main Menu appears. 8. If you want to configure the terminal for your RF network, continue with the next section, “Configuring RF Communications.” If you want to configure the serial port, follow the instructions for “Configuring the Serial Port Parameters” later in this chapter.
Configuring RF Communications The TRAKKER Antares 2455 terminal communicates with a host computer in Intermec’s 2.4 GHz RF network through the DCS 300, the Model 200 Controller, or directly through the access points. The terminal uses one of these RF network protocol options to communicate with other devices: •
UDP Plus
•
TCP/IP
The terminal ships with only one of these RF network protocols. In a UDP Plus network, the terminal communicates through the DCS 300 or Model 200 Controller to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network. In a TCP/IP network, the terminal communicates through the access point, which is connected to the host on an Ethernet or token ring network. Note: The T2455 will communicate with either the DCS 300 or the Model 200 Controller. The DCS 300 is a new data collection server that replaces the Model 200 Controller. Host TCP/IP Direct Connect
UDP Plus
Ethernet
Access point
T2455
DCS 300
2455U.048
Access point
T2455
2-19
Page 70
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
You need to configure these network parameters to begin using RF communications: Network Parameter
Default Value
Network activate
Disabled
Controller IP address (UDP Plus)
0.0.0.0
Host IP address (TCP/IP)
0.0.0.0
Terminal IP address
0.0.0.0
RF domain
0
RF security identification (ID)
None (not set)
Network port (UDP Plus)
5555
Network port (TCP/IP)
23
Use the TRAKKER Antares 2400 Menu System to set these parameters. For a detailed definition of these parameters, see Chapter 4, “Operating the Terminal in a Network.” Note: If the terminal is on a different IP subnetwork from the DCS 300, controller, or host, you must also configure the default router and subnet mask. To configure the terminal to use RF communications 1. Configure the DCS 300 (UDP Plus), Model 200 Controller (UDP Plus), or host (TCP/IP). For help, see your server, controller, or host system manual. 2. Configure the access point. For help, see your access point user’s manual.
: V
3. Configure the terminal. From the Main Menu, press or to choose the Configuration Menu and then press . The Configuration Menu appears.
4. Press V to choose the Communications Menu and then press The Communications Menu appears. 5. Press to choose the Primary Network command. The Primary Network screen Note: If you are not in the TRAKKER Antares 2400 Menu System, press to access the Main Menu.
appears.
2-20