Page 401
nugget Using the Default Applications
Or:
D
To set the preamble or postamble using the +., ++, or +% reader commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A
*+/+.* *+/+.*
Enter Accumulate Mode / Set Preamble B
*+/++* *+/++*
Enter Accumulate Mode / Set Postamble C
*+/+%* *+/+%*
2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode
*-/* *-/*
4. Repeat Steps 1 to 3 to set another preamble or postamble.
Full ASCII Mode for Code 39 With the EM9560.BIN application, you can configure Full ASCII mode for Code 39 using any of these commands: •
Code 39 configuration command (CB)
•
Full ASCII configuration command (RB)
•
Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader command (-$)
The last two commands are compatible with the 95XXs. Each command is described next. For help with the Code 39 configuration command (CB), see Chapter 9, “Configuration Command Reference.” Note: Use the CB configuration command unless your terminals need to be compatible with the 95XXs in your data collection network.
D-7
Page 402
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Command:
Full ASCII configuration command (RB)
Purpose:
Configures the terminal to use Code 39 Full ASCII mode (enabled) or Code 39 NonFull ASCII mode (disabled). For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.
Syntax:
RBdata Acceptable values for data are: 0 1
Scan:
Disabled Enabled
One of these bar code labels: Disable Full ASCII Mode
Enable Full ASCII Mode
*$+RB0*
*$+RB1*
*$+RB0*
Command:
*$+RB1*
Enter Full ASCII Mode reader command
Purpose:
Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by using a two-character encoding scheme to extend the character set to 128 characters. For a list of ASCII characters, see the “Full ASCII Table” in Appendix B.
Syntax:
+$
Scan:
Full ASCII
*+$* *+$*
Command:
Exit Full ASCII Mode reader command
Purpose:
Exits Code 39 Full ASCII mode and puts the terminal in Code 39 Non-Full ASCII mode (one-character encoding scheme).
Syntax:
-$
Scan:
Exit Full ASCII
*/M/D* *-$*
D-8
Page 403
nugget Using the Default Applications
D
Unsupported 95XX Features These 95XX features are not supported by the EM9560.BIN application on the T2455: •
Display Setting configuration command (OD) (buffered or transparent display).
•
Command Override reader (data entry) command (DLE).
•
Right Host Message reader command (HT).
•
Preamble A Required configuration command (OA).
•
Computer Response Required Mode (CRRM) configuration command (PB), Enter CRRM reader command (./), and Exit CRRM reader command (.-).
•
Resume IRL configuration command (XG).
•
Separate transmit and receive EOM characters (PI and PJ). The configurable EOM (PF, YZ) is used for both transmit and receive EOM.
•
Capacity reader command (%$).
•
Forward and Review reader commands (%+ and %/).
•
Download Program command from the 9154 or 9161 controller. Use the Transmit File reader command. For help, see Chapter 8, “Reader Command Reference.”
Note: Although these 95XX features are not supported, the T2455 does have many additional features (RF communications) that are not available on the 95XXs.
Running APPTSK.BIN and EM9560.BIN There are two ways to run APPTSK.BIN or EM9560.BIN: •
Use the Run Program reader command.
•
Use the TRAKKER Antares 2400 Menu System.
The instructions in this section explain how to use the Run Program reader command. For help using the TRAKKER Antares 2400 Menu System to run an application, see Chapter 5, “Using Custom Applications.”
D-9
Page 404
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget
Running APPTSK.BIN and EM9560.BIN (continued) To run APPTSK.BIN or EM9560.BIN on the terminal 1. Scan one of these bar code labels: Run APPTSK.BIN
*/O/OC/ZAPPTSK/NBIN* *//C:APPTSK.BIN* Run EM9560.BIN
*/O/OC/ZEM9560/NBIN* *//C:EM9560.BIN*
The terminal boots, resets all firmware, and runs the application. The initial screen for the application appears. You see one of these screens: APPTSK.BIN Screen 1998/01/00
EM9560.BIN Screen
12:00:00
2. Scan this bar code label to toggle the clock display on or off. Toggle Clock Display
*CLOCKDISPLAY* *CLOCKDISPLAY*
3. Use the application to scan bar code labels, enter data through the keyboard, and transmit data. The next section lists some examples of how you can use the applications.
D-10
Page 405
nugget Using the Default Applications
D
Example 1 Use the application to troubleshoot and test communications before loading and running your data collection application. Connect the terminal to your network. Type data (“Hello World”) on the TRAKKER Antares terminal keyboard or scan a bar code label. The data is sent out all serial and network ports and should be received by the host if your terminal is installed and configured correctly. Send data from the host and verify that the data displays on the terminal screen.
Example 2 Connect a serial input device, such as a 2D scanner, to a serial port on the TRAKKER Antares terminal. Data from the input device is displayed on the terminal screen and transmitted out the network (RF) port.
Example 3 Connect the TD2400 communications dock to a serial port on the T2485. Use a T2420 to collect data. Use the TD2400 communications dock to upload data from the T2420 to the T2485. Data is transmitted to the T2485 and out the RF port to the connected network devices.
Example 4 Use the T248X as a gateway between the CrossBar network and the Ethernet or RF network. Connect the T248X as a downline device in your CrossBar network. Connect the T2480/1 with the Ethernet option to your Ethernet network, or connect the T2485/6 to your RF network. While running the APPTSK.BIN or EM9560.BIN application, you can send data from the Ethernet or RF network through the T248X to the 9154 or 9161 and vice versa.
Example 5 Connect the COM1 serial port to the COM2 serial port on a T246X or T248X terminal. Use the terminal to configure itself by typing and entering configuration commands on the keypad or keyboard.
Example 6 Connect the serial port on the T248X to the serial port on the T246X terminal. Use the T248X to configure the T246X by typing and entering configuration commands on the T248X keypad.
D-11
Page 406
D-12
Page 407
I Index
Page 408
Page 409
Index
Symbols key, See Control key b to ^, See Function keys h, See Contrast key f, See Suspend/Resume key key, See Function Right key key, See Function Left key key, See Shift key
Numbers 2.4 GHz RF network access point, configuring, 4-15 activating, 9-67 DCS 300, configuring, 4-14 equipment required, 4-14 illustrated, 4-10 to 4-13 installing, overview, 4-9 protocols, defined, 4-30 to 4-32 roaming between access points, 4-18 terminal, configuring, 4-15 3270 and 5250 screen mapping, See screen mapping 3270 and 5250 terminal emulation keyboards, using, 1-16 to 1-21 starting, 2-26 See also TRAKKER Antares Terminal Emulation User's Guide 4MB flash memory option, 9-52 900 MHz RF network, connecting the T2455 to, 4-6 9154 or 9161 controller time broadcast command, 8-10 9189 Gateway requires Polling Mode D protocol, 4-6
A ABC Codabar, 9-14 Abort Program reader command, 8-13 About TRAKKER Antares 2400 screen, defined, 3-8 AC power supply, 1-22 AC power supply adapter cable described, 1-6 installing, 2-29 accent marks, typing, 1-20 access point configuring, 4-15 roaming between, 4-18 Access Point screen, defined, 7-20 accessories for the terminal, 1-6 Accumulate mode, using reader commands, 8-3 Acknowledgement Delay Lower Limit command, 9-7 Acknowledgement Delay Upper Limit command, 9-8 adapter cable See AC power supply adapter cable. See COM port adapter cable. See keyboard adapter cable. See RS-232 null-modem adapter cable.
I address controller IP, configuring, 9-39 default router, configuring, 9-43 host IP, configuring, 9-57 IP, defined, 4-16 terminal IP, configuring, 9-101 AFF command, 9-55 Affirmative Acknowledge, See Handshake command AIAG check digit, Code 39, 9-20 alphanumeric keyboard illustrated, 1-17 options, described, 1-16 American Blood Commission, See ABC Codabar Antares, See TRAKKER Antares terminal antenna illustrated, 1-5 installing, 2-5 ordering parts, 6-17 Append Time command, 9-9 Application Efficiency screen, defined, 7-21 Application Events screen, defined, 7-7 applications APPTSK.BIN, default application, D-3 converting binary files, 5-7 IRL programs, 5-7 JANUS and TRAKKER Antares, 5-7 developing, 5-5, 5-18 downloading from controller, 5-12 from host in a TCP/IP network, 4-25 through serial port, 5-8 EM9560.BIN, default application, D-3 execution space, described, 1-26 exiting, 8-13 EZBuilder, developing with, 5-6 host computer, transferring data, 4-7, 4-21 to 4-25 Malloc diagnostic screen, defined, 7-22 options, described, A-5 overview, downloading and running, 5-3 programming specifications, 5-4 PSK, developing with, 5-6 restarting, 8-9 running, 5-16, 8-20 running APPTSK.BIN, D-9 running EM9560.BIN, D-9 starting, 2-26 TRAKKER Antares 2400 Menu System, using, 3-5 to 3-14 APPTSK.BIN application defined, D-3 running, D-9 ARP, defined, 4-32
I-3
Page 410
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual
ASCII bar code chart, B-6 to B-10 Code 39, full, 9-19 Code 39, mixed-full, 9-19 Code 39, non-full, 9-18 control characters list of, B-5 postamble and preamble, entering, 3-11 extended characters, configuring, 3-11 table of character equivalents, B-3 to B-5 audio signals keyclicks, enabling or disabling, 9-61 list of, 1-21 testing, 7-12 volume, adjusting, 9-13 auto-advancing through fields, configuring, 3-11 Automatic mode, configuring, 9-86 Automatic Shutoff command, 9-10 automatically turning the terminal off, 9-10
B back panel, removing, 6-20 Backspace reader command, 8-5 backup battery charging, 1-23, 2-15 described, 1-22 disposing of safely, 6-24 low battery charge, 1-24, 6-6 power specifications, A-4 replacing, 6-22 status, 7-11 temperature range for charging, 1-24 temperature range for charging, A-5 when to replace, 1-24, 7-11 bar code labels ASCII chart, B-6 to B-10 bar code symbologies, enabling, 3-17 conventions, defined, xxi creating, about start/stop codes, 9-3 decode security, configuring, 9-42 Multiple-Read labels, 8-9 reader commands, troubleshooting, 6-5, 6-10 regular labels, 8-9 rules for creating, 3-15 scanning accumulating data, 8-3 configuring the terminal, 3-3, 3-15 troubleshooting, 6-14 bar code symbologies choosing, 3-4 Codabar, configuring, 9-14 Code 11, configuring, 9-15 Code 128, configuring, 9-24 Code 16K, configuring, 9-16 Code 2 of 5, configuring, 9-17
I-4 bar code symbologies (continued) Code 39, configuring, 9-18 Code 49, configuring, 9-22 Code 93, configuring, 9-23 configuration commands, list of, 3-28, 9-4, A-10 enabling, quick reference, 3-17 list of, A-6 MSI, configuring, 9-66 Plessey, configuring, 9-72 troubleshooting bad decode, 6-5 UPC/EAN, configuring, 9-106 Battery Status screen, defined, 7-11 Baud Rate command, 9-11 beep audio signals for status, 1-21 Beep Volume command, 9-13 testing, 7-12 three low beeps, troubleshooting, 6-9, 6-10, 6-11 Beeper Test screen, defined, 7-12 BFSK, defined, 9-84 binary files, converting, 5-7 Binary protocol described, 4-5 parameters to configure, 4-5 binary, table of ASCII characters, B-3 to B-5 blue keys, using, 1-17 Boot Menu troubleshooting, 6-6 using, 6-18 Boot Menu, first time, 2-15 Boot Terminal reader command, 8-7 booting the terminal, 6-15 configuration used, 3-19 configuring the key, 6-18, 9-78 POST failed, error message, 6-6 turning on the terminal, 2-28 warm boot, 8-9 bottom back panel, illustrated, 1-9 bracket, See mounting bracket f
C cables, list of accessories, 1-6 capitalizing characters keyboard, using, 1-19 Keypad Caps Lock command, using, 9-61 Caps Lock status light, 1-12, 1-19 cautions, defined, xviii CGA-compatible display, described, 1-10, A-5 change configuration configuration commands, using, 9-6 reader commands, using, 8-8 Character mode EOM, described, 4-5, 9-50 troubleshooting, 6-8 characters, table of, C-3 to C-7