Page 391

nugget CODE39 International Character Support

C

English and Western European Character Set (continued) Character

Decimal

Hexadecimal

Character

Decimal

Hexadecimal

\

92

5C y

121

79

]

93

5D z

122

^

94

5E

{

123

7A 7B

_ (underline)

95

5F

| (solid pipe)

124

7C

`

96

60

}

125

7D a

97

61

~

126

7E b

98

62 z

127

7F c

99

63

Ç

128 d

100

64

ü

129

80 81 e

101

65

é

130

82 f

102

66

â

131

83 g

103

67

ä

132

84 h

104

68

à

133

85 i

105

69

å

134

86 j

106

6A

ç

135 k

107

6B

ê

136

87 88 l

108

6C

ë

137

89 m

109

6D

è

138

8A n

110

6E

ï

139

8B o

111

6F

î

140

8C p

112

70

ì

141

8D q

113

71

Ä

142

8E r

114

72

Å

143

8F s

115

73

É

144

90 t

116

74

æ

145

91 u

117

75

Æ

146

92 v

118

76

ô

147

93 w

119

77

ö

148

94 x

120

78

ò

149

95

C-5

Page 392

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

English and Western European Character Set (continued) Character

Decimal

Hexadecimal

Character

Decimal

Hexadecimal

û

150

96

ù

151

97

· ½

179

B3

180

B4

ÿ

152

98

Á

181

B5

Ö

153

99

Â

182

B6

Ü

154

9A

À

183

B7

ø

155

9B

©

184

B8

£

156

9C

185

B9

Ø

157

9D

186

BA

×

158

9E

187

BB

ƒ

159

9F

188

BC

á

160

A0

Ô Â È Î €

189

BD

í

161

A1

¥

190

BE

ó

162

A2

191

BF

ú

163

A3

192

C0

ñ

164

A4

193

C1

Ñ a

165

A5

194

C2

166

A6

195

C3 o

167

A7

¿

168

®

196

C4

197

C5

169

A8 A9

¹ º ¿ ¾ ¼ ¶ À ã

198

C6

¬ (not symbol)

170

AA

Ã

199

C7

½

171

AB

200

C8

¼

172

201

C9

•

AC

173

AD

202

CA

«

174

AE

203

CB

»

175

204

CC

176

AF B0

205

CD

177

B1

Ë Å Ú × Ñ Á Ý

206

CE

178

B2

¤

207

CF

ã ä å

C-6

Page 393

nugget CODE39 International Character Support

C

English and Western European Character Set (continued) Character

Decimal

Hexadecimal

Character

Decimal

Hexadecimal

«

208

D0

þ

232

E8

Ð

209

D1

Ú

233

E9

Ê

210

D2

Û

234

EA

Ë

211

D3

Ù

235

EB

È

212

D4

ý

236

EC

|

213

D5

Ý

237

ED

Í

214

D6

¯

238

EE

Î

215

D7

´

239

EF

Ï

216

D8

-

240

F0

217

D9

±

241

F1

218

DA

242

F2

219

DB

= ¾

243

F3

220

DC

244

¦ (broken pipe)

221

DD

§

245

F4 F5

Ì

222

DE

÷

246

F6

Þ

223

DF

¸

247

F7

Ó

224

E0

° (degree)

248

F8

β

225

E1

¨

249

F9

Ô

226

E2

• (dot)

250

FA

Ò

227

E3

¹ (superscript)

251

FB

õ

228

E4

³ (superscript)

252

FC

Õ

229

E5

² (superscript)

253

FD

µ

230

æ

254

FE

Þ

231

E6 E7

Space

255

FF

» ¸ à ß

C-7

Page 394

This page is a scan with no text; see it in the PDF.

Page 395

D Using the Default Applications

Page 396

D-2

Page 397

nugget Using the Default Applications

D

This appendix defines the APPTSK.BIN and EM9560.BIN applications that are shipped on the TRAKKER Antares 2455 terminal and explains how to use each application.

About the Applications Shipped on the Terminal The TRAKKER Antares 2455 terminal ships loaded with at least these two applications: •

APPTSK.BIN

•

EM9560.BIN

Both applications are stored on drive C. In addition to these two applications, your terminal may have a 3270, 5250, or VT/ANSI terminal emulation application stored on drive C. This section explains how to use the APPTSK.BIN and EM9560.BIN applications. For help with your terminal emulation applications, see the TRAKKER Antares Terminal Emulation User’s Guide.

Defining APPTSK.BIN and EM9560.BIN You can run and use APPTSK.BIN or EM9560.BIN at any time. The two applications are defined as follows: APPTSK.BIN This application is the default application on all terminals. In some error conditions or if you exit an application, the terminal resets and runs APPTSK.BIN. You can use APPTSK.BIN to scan, enter, transmit, and display data. EM9560.BIN This application emulates a subset of the functionality available on the Intermec 95XX terminals, such as the 9512 and 9560. You can use EM9560.BIN to scan, enter, transmit, and display data. APPTSK.BIN and EM9560.BIN include these features:

•

Works with any protocol that is supported on the terminal. Both the terminal and the device you are communicating with must use the same protocol (serial or RF) and parameter settings.

•

Displays the time and date, which can be toggled on and off.

•

Sends scanned or keyboard data out all serial or RF ports.

•

Buffers the keyboard data until you press Enter.

•

Receives data from any serial or RF port, displays the data on the terminal screen, and parses the data for commands.

•

Receives data through any serial port and transmits it out the RF port.

•

Receives data through the RF port and transmits it out all serial ports.

The main difference between the two applications is that you can use the EM9560.BIN application to emulate specific functions of the 95XXs.

D-3

Page 398

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget

Defining the Emulation Features of EM9560.BIN The T2455 is a programmable terminal that runs C/C++ applications. With the EM9560.BIN application, you can use the terminal as a remote input/output terminal in which all prompts and commands are controlled by the host computer. With this application, the terminal is similar to a 95XX in Data Entry mode with no application running. Note: For the 95XXs, Data Entry mode with no application running is also referred to as an unprogrammed state or 95XX dumb terminal mode. The EM9560.BIN application lets you use the terminal to emulate these specific 95XX features: •

An Enter key without any preceding data transmits an empty data packet.

•

The T2455 display is similar to but not identical to the 9560 buffered display mode.

•

All function keys transmit the corresponding characters F1, F2, and so on.

•

When Code 128 is configured for Standard Code 128 symbology and you scan a UCC/EAN label, the terminal will discard the Function 1 characters. Although this does not meet the industry standard for Code 128, it does emulate the 95XX, which was manufactured before the current standard was established. Other Code 128 configurations work as defined in this user’s manual.

•

The Set Time and Date reader (data entry) command is supported. When the terminal receives a time broadcast command (/+) from the 9154 or 9161 controller, the command sets the clock on the terminal. Note: With Version 5.X firmware or later, the Set Time and Date reader command is supported through the firmware and not just in the EM9560.BIN application.

D-4

•

The High Beep reader command is supported. When a backslash character (\) is sent to the terminal through any serial or network port, the terminal sounds a high beep.

•

The Low Beep reader command is supported. When the BEL character is sent to the terminal through any serial or network port, the terminal sounds a low beep.

•

When control codes (ANSI escape sequences) are sent to the terminal through any serial or network port, the terminal formats the display. For a list of control codes, see “Using Display Control Codes” later in this appendix.

•

Preamble A, Preamble B, and Postamble C are supported through the AA, AB, and AC configuration commands or through the reader commands +., ++, and +%. For help, see “Setting Preambles and Postambles” later in this appendix.

•

Full ASCII mode for Code 39 can be configured through the CB or RB configuration commands or through the reader commands +$ and -$. For help, see “Full ASCII Mode for Code 39” later in this appendix.

Page 399

nugget Using the Default Applications

•

D

The Exit Configuration Mode, Save Settings configuration command ($-) is not required, but bar code labels with this command scan correctly.

Using Display Control Codes You can use control codes to position the cursor or to format the terminal display. The EM9560.BIN application recognizes the display control codes listed next. Command

Control Code

Description or Action

Backspace

BS (08 Hex)

Moves the cursor one position to the left until the cursor reaches the first column. If the cursor is in the first column of any row except the first row, a Backspace command moves the cursor to the last column of the previous row.

Cursor Position

ESC[n;vH

Moves the cursor to the position specified by the n and v parameters where: n specifies the row or line number. v specifies the column number. If you enter zero or no parameter, n and v are set to one. If n or v exceeds the maximum row or column number on the display, the parameters are set to the screen’s maximum.

Erase Display

ESC[2J

Erases the entire display and returns the cursor to the home position (row 1, column 1). This command also erases the entire virtual display image (buffer with up to four rows of the most recently displayed data).

Home

CR (0D Hex)

Returns the cursor to the first column of the current row.

Next Line

LF (0A Hex)

Moves the cursor down one row in the current column position. If the cursor is already in the last row, a new line is added.

Restore Cursor Position

ESC[u

Restores the cursor position saved with a Save Cursor Position command. Each Restore Cursor Position command must be paired with a preceding Save Cursor Position command. If a Save Cursor Position command has not been previously entered, the cursor position will not change.

Save Cursor Position

ESC[s

Saves the current cursor position. Successive Save Cursor Position commands overwrite the previous position that was saved.

D-5

Page 400

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget

Setting Preambles and Postambles With the EM9560.BIN application, you can set Preamble A, Preamble B, and Postamble C on the T2455 and make the terminal compatible with the 95XXs. The preambles are prepended and the postamble is appended to the data that is transmitted through all the serial ports. Preamble A, Preamble B, and Postamble C can each be up to 25 ASCII characters in length. If you enter a preamble or postamble command without entering data, the preamble or postamble buffer is cleared. Syntax:

Scan:

Preamble A Preamble B Postamble C

AAdata or +.data ABdata or ++data ACdata or +%data

To set the preamble or postamble using the AA, AB, or AC configuration commands: 1. Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A

*+/$+AA* *+/$+AA*

Enter Accumulate Mode / Set Preamble B

*+/$+AB* *+/$+AB*

Enter Accumulate Mode / Set Postamble C

*+/$+AC* *+/$+AC*

2. Scan a value for data from the “Full ASCII Bar Code Chart” in Appendix B. The preamble or postamble can be from 1 to 25 characters. 3. Scan this bar code: Exit Accumulate Mode

*-/* *-/*

4. Repeat Steps 1 to 3 to set another preamble or postamble.

D-6