Page 371
CODE39 Nugget Terminal Specifications
A
Default Configuration for Operations Parameter
Default
Append Time
Disabled
Automatic Shutoff
0 minutes (disabled)
Beep Volume
Very loud
Command Processing
All reader commands enabled
Decode Security
Moderate
Display Contrast
3 (maximum contrast or brightness)
Display Font Type
8x8 font
Display Row Spacing
0
Display Video Mode
Original
Flash Memory Configuration
Flash memory for double-byte fonts
Keypad Caps Lock
Caps lock off
Keypad Clicker
Enabled
Keypad Type
Hardware default
Postamble
No characters (disabled)
Preamble
No characters (disabled)
RAM Drive Size
0 (no RAM drive)
Resume Execution
Allowed
Scan Ahead
Disabled
Scanner Mode
One-Shot mode
Scanner Redundancy
Normal
Scanner Selection
All compatible scanners
Scanner Timeout
Disabled (no timeout)
Scanner Trigger
Level triggering
Suspend/Resume Control
Enabled
Time and Date
960101120000
Time in Seconds
Disabled
A-11
Page 372
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Default Configuration for RF Network Communications
A-12
Parameter
Default
Acknowledgement Delay Lower Limit
300 ms
Acknowledgement Delay Upper Limit
5000 ms
Controller Connect Check Receive Timer
60 seconds
Controller Connect Check Send Timer
35 seconds
Controller IP Address
0.0.0.0
Default Router
0.0.0.0
Dynamic Host Configuration Protocol (DHCP)
Disabled
Host IP Address
0.0.0.0
Maximum Retries
7
Network Activate
Disabled
Network Loopback
Disabled
Network Port
23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network
RF Domain
0
RF Inactivity Timeout
5 seconds
RF Roaming Flag
Allowed
RF Security Identification (ID)
None
RF Transmit Mode
BFSK
RF Wakeup On Broadcast
No (disabled)
Subnet Mask
255.255.255.0
TCP Maximum Retries
12
TCP/IP Maximum Transmit Timeout
20 seconds
Terminal IP Address
0.0.0.0
Page 373
CODE39 Nugget Terminal Specifications
A
Default Configuration for Serial Network Communications Parameter
Default
Baud Rate
19200
Configuration Commands Via Serial Port
Enabled without TMF
Data Bits
7
End of Message (EOM)
\x03 (hexadecimal value for ETX)
Flow Control
None
Handshake
Disabled
LRC (Longitudinal Redundancy Check)
Disabled
Parity
Even
Poll (Polling)
Disabled
Scanner Port (COM4)
Scanner enabled
Serial Port Protocol
Configurable
Start of Message (SOM)
\x02 (hexadecimal value for STX)
Stop Bits
1
Timeout Delay
10 seconds
Note: The defaults listed in this table apply to all COM ports.
A-13
Page 374
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the TRAKKER Antares 2455 terminal. The configuration commands are listed in alphabetic order by syntax.
A-14
Syntax
Command
For Help, See Page
ADdata
Preamble
9-75
AEdata
Postamble
9-74
BVdata
Beep Volume
9-13
CAdata
Interleaved 2 of 5 Code (I 2 of 5)
9-59
CBdata
Code 39
9-18
CCdata
Code 2 of 5 (2 of 5)
9-17
CDdata
Codabar
9-14
CEdata
UPC/EAN
9-106
CFdata
Code 93
9-23
CGdata
Code 11
9-15
CHdata
Code 128
9-24
CIdata
Plessey
9-72
CJdata
Code 49
9-22
CKdata
Code 49 Function Code 1
9-22
CLdata
Code 49 Function Code 2
9-22
CMdata
Code 49 Function Code 3
9-22
CNdata
MSI
9-66
CPdata
Code 16K
9-16
CSdata
Decode Security
9-42
DAdata
Time in Seconds
9-104
DBdata
Time and Date
9-102
DCdata
Command Processing
9-31
DEdata
Append Time
9-9
DJdata
Display Contrast
9-45
DLdata
Display Row Spacing
9-47
DNdata
Display Video Mode
9-48
DTdata
Display Font Type
9-46
EFdata
Suspend/Resume Control
9-98
Page 375
CODE39 Nugget Terminal Specifications
A
Configuration Commands by Syntax (continued) Syntax
Command
For Help, See Page
ERdata
Resume Execution
9-78
EZdata
Automatic Shutoff
9-10
FFdata
Flash Memory Configuration
9-52
FRdata
RAM Drive Size
9-77
HBdata
Poll (Polling) (COM1 only)
9-73
IAdata
Baud Rate (COM1 only)
9-11
IBdata
Parity (COM1 only)
9-70
ICdata
Stop Bits (COM1 only)
9-95
IEdata
Timeout Delay (COM1 only)
9-104
IFdata
LRC (Longitudinal Redundancy Check) (COM1 only)
9-63
IIdata
Data Bits (COM1 only)
9-40
ILdata
Flow Control (COM1 only)
9-53
ITdata
Configuration Commands Via Serial Port (COM1 only)
9-34
IXdata
Scanner Port (COM4)
9-87
KAdata
Keypad Caps Lock
9-61
KCdata
Keypad Clicker
9-61
KTdata
Keypad Type
9-62
NAdata
Network Activate
9-67
NCdata
Controller IP Address (UDP Plus network)
9-39
NCdata
Host IP Address (TCP/IP network)
9-57
NDdata
Terminal IP Address
9-101
NGdata
Network Port
9-69
NHdata
TCP/IP Maximum Transmit Timeout
9-99
NIdata
Dynamic Host Configuration Protocol (DHCP)
9-49
NJdata
TCP Maximum Retries
9-98
NLdata
Network Loopback
9-68
NPdata
Controller Connect Check Receive Timer
9-36
NQdata
Controller Connect Check Send Timer
9-37
NRdata
Maximum Retries
9-64
NSdata
Subnet Mask
9-96
A-15
Page 376
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Configuration Commands by Syntax (continued)
A-16
Syntax
Command
For Help, See Page
NUdata
Acknowledgement Delay Upper Limit
9-8
NVdata
Acknowledgement Delay Lower Limit
9-7
NXdata
Default Router
9-43
PEdata
Start of Message (SOM) (COM1 only)
9-94
PFdata
End of Message (EOM) (COM1 only)
9-50
PGdata
Handshake (COM1 only)
9-55
RBdata
RF Wakeup On Broadcast
9-85
RRdata
RF Roaming Flag
9-82
RSdata
RF Security Identification
9-82
RTdata
RF Transmit Mode
9-84
RWdata
RF Domain
9-79
RYdata
RF Inactivity Timeout
9-80
SAdata
Scanner Timeout
9-90
SBdata
Scanner Mode
9-86
SCdata
Scanner Trigger
9-91
SDdata
Scan Ahead
9-85
SRdata
Scanner Redundancy
9-88
SSdata
Scanner Selection
9-89
YAdata
Baud Rate
9-11
YBdata
Parity
9-70
YCdata
Stop Bits
9-95
YEdata
Timeout Delay
9-104
YFdata
LRC (Longitudinal Redundancy Check)
9-63
YIdata
Data Bits
9-40
YJdata
Handshake (also known as AFF)
9-55
YLdata
Flow Control
9-53
YRdata
Poll (Polling)
9-73
YTdata
Configuration Commands Via Serial Port
9-34
YUdata
Serial Port Protocol
9-92
YYdata
Start of Message (SOM)
9-94
YZdata
End of Message (EOM)
9-50
Page 377
B Full ASCII Charts
Page 378
Page 379
nugget CODE39 Full ASCII Charts
B
This appendix contains a full ASCII chart and charts of Code 39 bar code labels that you can scan with an input device connected to the TRAKKER Antares 2455 terminal.
Full ASCII Table This table lists the ASCII characters and their binary, hexadecimal, and Code 39 equivalents.
Full ASCII Table Binary0
Hex1
Decimal
Code 39
ASCII2
Binary0
Hex1
Decimal
Code 39
ASCII2
00000000 00000001 00000010 00000011
00 01 02 03
00 01 02 03
%U $A $B $C
NUL SOH STX ETX
00100000 00100001 00100010 00100011
20 21 22 23
32 33 34 35
SP /A /B /C
SP3 ! " #
00000100 00000101 00000110 00000111
04 05 06 07
04 05 06 07
$D $E $F $G
EOT ENQ ACK BEL
00100100 00100101 00100110 00100111
24 25 26 27
36 37 38 39
/D /E /F /G
$ % & '
00001000 00001001 00001010 00001011
08 09 0A 0B
08 09 10 11
$H $I $J $K
BS HT LF VT
00101000 00101001 00101010 00101011
28 29 2A 2B
40 41 42 43
/H /I /J /K
( ) * +
00001100 00001101 00001110 00001111
0C 0D 0E 0F
12 13 14 15
$L $M $N $O
FF CR SO SI
00101100 00101101 00101110 00101111
2C 2D 2E 2F
44 45 46 47
/L /M /N /O
, . /
00010000 00010001 00010010 00010011
10 11 12 13
16 17 18 19
$P $Q $R $S
DLE DC1 DC2 DC3
00110000 00110001 00110010 00110011
30 31 32 33
48 49 50 51
/P4 /Q /R /S
0 1 2 3
00010100 00010101 00010110 00010111
14 15 16 17
20 21 22 23
$T $U $V $W
DC4 NAK SYN ETB
00110100 00110101 00110110 00110111
34 35 36 37
52 53 54 55
/T /U /V /W
4 5 6 7
00011000 00011001 00011010 00011011
18 19 1A 1B
24 25 26 27
$X $Y $Z %A
CAN EM SUB ESC
00111000 00111001 00111010 00111011
38 39 3A 3B
56 57 58 59
/X /Y /Z %F
8 9 : ;
00011100 00011101 00011110 00011111
1C 1D 1E 1F
28 29 30 31
%B %C %D %E
FS GS RS US
00111100 00111101 00111110 00111111
3C 3D 3E 3F
60 61 62 63
%G %H %I %J
< = > ?
B-3
Page 380
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39
Full ASCII Table (continued) Binary0
Hex1
Decimal
Code 39
ASCII2
Binary0
Hex1
Decimal
Code 39
ASCII2
01000000 01000001 01000010 01000011
40 41 42 43
64 65 66 67
%V A B C
@ A B C
01100000 01100001 01100010 01100011
60 61 62 63
96 97 98 99
%W +A +B +C
` a b c
01000100 01000101 01000110 01000111
44 45 46 47
68 69 70 71
D E F G
D E F G
01100100 01100101 01100110 01100111
64 65 66 67
100 101 102 103
+D +E +F +G d e f g
01001000 01001001 01001010 01001011
48 49 4A 4B
72 73 74 75
H I J K
H I J K
01101000 01101001 01101010 01101011
68 69 6A 6B
104 105 106 107
+H +I +J +K h i j k
01001100 01001101 01001110 01001111
4C 4D 4E 4F
76 77 78 79
L M N O
L M N O
01101100 01101101 01101110 01101111
6C 6D 6E 6F
108 109 110 111
+L +M +N +O l m n o
01010000 01010001 01010010 01010011
50 51 52 53
80 81 82 83
P Q R S
P Q R S
01110000 01110001 01110010 01110011
70 71 72 73
112 113 114 115
+P +Q +R +S p q r s
01010100 01010101 01010110 01010111
54 55 56 57
84 85 86 87
T U V W
T U V W
01110100 01110101 01110110 01110111
74 75 76 77
116 117 118 119
+T +U +V +W t u v w
01011000 01011001 01011010 01011011
58 59 5A 5B
88 89 90 91
X Y Z %K
X Y Z [
01111000 01111001 01111010 01111011
78 79 7A 7B
120 121 122 123
+X +Y +Z %P x y z {
01011100 01011101 01011110 01011111
5C 5D 5E 5F
92 93 94 95
%L %M %N %O
\ ] ^ _
01111100 01111101 01111110 01111111
7C 7D 7E 7F
124 125 126 127
%Q %R %S %T5
| } ~ n6
B-4