For the Intermec 2455

Page 371

CODE39 Nugget Terminal Specifications

A

Default Configuration for Operations Parameter

Default

Append Time

Disabled

Automatic Shutoff

0 minutes (disabled)

Beep Volume

Very loud

Command Processing

All reader commands enabled

Decode Security

Moderate

Display Contrast

3 (maximum contrast or brightness)

Display Font Type

8x8 font

Display Row Spacing

0

Display Video Mode

Original

Flash Memory Configuration

Flash memory for double-byte fonts

Keypad Caps Lock

Caps lock off

Keypad Clicker

Enabled

Keypad Type

Hardware default

Postamble

No characters (disabled)

Preamble

No characters (disabled)

RAM Drive Size

0 (no RAM drive)

Resume Execution

Allowed

Scan Ahead

Disabled

Scanner Mode

One-Shot mode

Scanner Redundancy

Normal

Scanner Selection

All compatible scanners

Scanner Timeout

Disabled (no timeout)

Scanner Trigger

Level triggering

Suspend/Resume Control

Enabled

Time and Date

960101120000

Time in Seconds

Disabled

A-11

Page 372

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

Default Configuration for RF Network Communications

A-12

Parameter

Default

Acknowledgement Delay Lower Limit

300 ms

Acknowledgement Delay Upper Limit

5000 ms

Controller Connect Check Receive Timer

60 seconds

Controller Connect Check Send Timer

35 seconds

Controller IP Address

0.0.0.0

Default Router

0.0.0.0

Dynamic Host Configuration Protocol (DHCP)

Disabled

Host IP Address

0.0.0.0

Maximum Retries

7

Network Activate

Disabled

Network Loopback

Disabled

Network Port

23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network

RF Domain

0

RF Inactivity Timeout

5 seconds

RF Roaming Flag

Allowed

RF Security Identification (ID)

None

RF Transmit Mode

BFSK

RF Wakeup On Broadcast

No (disabled)

Subnet Mask

255.255.255.0

TCP Maximum Retries

12

TCP/IP Maximum Transmit Timeout

20 seconds

Terminal IP Address

0.0.0.0

Page 373

CODE39 Nugget Terminal Specifications

A

Default Configuration for Serial Network Communications Parameter

Default

Baud Rate

19200

Configuration Commands Via Serial Port

Enabled without TMF

Data Bits

7

End of Message (EOM)

\x03 (hexadecimal value for ETX)

Flow Control

None

Handshake

Disabled

LRC (Longitudinal Redundancy Check)

Disabled

Parity

Even

Poll (Polling)

Disabled

Scanner Port (COM4)

Scanner enabled

Serial Port Protocol

Configurable

Start of Message (SOM)

\x02 (hexadecimal value for STX)

Stop Bits

1

Timeout Delay

10 seconds

Note: The defaults listed in this table apply to all COM ports.

A-13

Page 374

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the TRAKKER Antares 2455 terminal. The configuration commands are listed in alphabetic order by syntax.

A-14

Syntax

Command

For Help, See Page

ADdata

Preamble

9-75

AEdata

Postamble

9-74

BVdata

Beep Volume

9-13

CAdata

Interleaved 2 of 5 Code (I 2 of 5)

9-59

CBdata

Code 39

9-18

CCdata

Code 2 of 5 (2 of 5)

9-17

CDdata

Codabar

9-14

CEdata

UPC/EAN

9-106

CFdata

Code 93

9-23

CGdata

Code 11

9-15

CHdata

Code 128

9-24

CIdata

Plessey

9-72

CJdata

Code 49

9-22

CKdata

Code 49 Function Code 1

9-22

CLdata

Code 49 Function Code 2

9-22

CMdata

Code 49 Function Code 3

9-22

CNdata

MSI

9-66

CPdata

Code 16K

9-16

CSdata

Decode Security

9-42

DAdata

Time in Seconds

9-104

DBdata

Time and Date

9-102

DCdata

Command Processing

9-31

DEdata

Append Time

9-9

DJdata

Display Contrast

9-45

DLdata

Display Row Spacing

9-47

DNdata

Display Video Mode

9-48

DTdata

Display Font Type

9-46

EFdata

Suspend/Resume Control

9-98

Page 375

CODE39 Nugget Terminal Specifications

A

Configuration Commands by Syntax (continued) Syntax

Command

For Help, See Page

ERdata

Resume Execution

9-78

EZdata

Automatic Shutoff

9-10

FFdata

Flash Memory Configuration

9-52

FRdata

RAM Drive Size

9-77

HBdata

Poll (Polling) (COM1 only)

9-73

IAdata

Baud Rate (COM1 only)

9-11

IBdata

Parity (COM1 only)

9-70

ICdata

Stop Bits (COM1 only)

9-95

IEdata

Timeout Delay (COM1 only)

9-104

IFdata

LRC (Longitudinal Redundancy Check) (COM1 only)

9-63

IIdata

Data Bits (COM1 only)

9-40

ILdata

Flow Control (COM1 only)

9-53

ITdata

Configuration Commands Via Serial Port (COM1 only)

9-34

IXdata

Scanner Port (COM4)

9-87

KAdata

Keypad Caps Lock

9-61

KCdata

Keypad Clicker

9-61

KTdata

Keypad Type

9-62

NAdata

Network Activate

9-67

NCdata

Controller IP Address (UDP Plus network)

9-39

NCdata

Host IP Address (TCP/IP network)

9-57

NDdata

Terminal IP Address

9-101

NGdata

Network Port

9-69

NHdata

TCP/IP Maximum Transmit Timeout

9-99

NIdata

Dynamic Host Configuration Protocol (DHCP)

9-49

NJdata

TCP Maximum Retries

9-98

NLdata

Network Loopback

9-68

NPdata

Controller Connect Check Receive Timer

9-36

NQdata

Controller Connect Check Send Timer

9-37

NRdata

Maximum Retries

9-64

NSdata

Subnet Mask

9-96

A-15

Page 376

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget

Configuration Commands by Syntax (continued)

A-16

Syntax

Command

For Help, See Page

NUdata

Acknowledgement Delay Upper Limit

9-8

NVdata

Acknowledgement Delay Lower Limit

9-7

NXdata

Default Router

9-43

PEdata

Start of Message (SOM) (COM1 only)

9-94

PFdata

End of Message (EOM) (COM1 only)

9-50

PGdata

Handshake (COM1 only)

9-55

RBdata

RF Wakeup On Broadcast

9-85

RRdata

RF Roaming Flag

9-82

RSdata

RF Security Identification

9-82

RTdata

RF Transmit Mode

9-84

RWdata

RF Domain

9-79

RYdata

RF Inactivity Timeout

9-80

SAdata

Scanner Timeout

9-90

SBdata

Scanner Mode

9-86

SCdata

Scanner Trigger

9-91

SDdata

Scan Ahead

9-85

SRdata

Scanner Redundancy

9-88

SSdata

Scanner Selection

9-89

YAdata

Baud Rate

9-11

YBdata

Parity

9-70

YCdata

Stop Bits

9-95

YEdata

Timeout Delay

9-104

YFdata

LRC (Longitudinal Redundancy Check)

9-63

YIdata

Data Bits

9-40

YJdata

Handshake (also known as AFF)

9-55

YLdata

Flow Control

9-53

YRdata

Poll (Polling)

9-73

YTdata

Configuration Commands Via Serial Port

9-34

YUdata

Serial Port Protocol

9-92

YYdata

Start of Message (SOM)

9-94

YZdata

End of Message (EOM)

9-50

Page 377

B Full ASCII Charts

Page 378

This page is a scan with no text; see it in the PDF.

Page 379

nugget CODE39 Full ASCII Charts

B

This appendix contains a full ASCII chart and charts of Code 39 bar code labels that you can scan with an input device connected to the TRAKKER Antares 2455 terminal.

Full ASCII Table This table lists the ASCII characters and their binary, hexadecimal, and Code 39 equivalents.

Full ASCII Table Binary0

Hex1

Decimal

Code 39

ASCII2

Binary0

Hex1

Decimal

Code 39

ASCII2

00000000 00000001 00000010 00000011

00 01 02 03

00 01 02 03

%U $A $B $C

NUL SOH STX ETX

00100000 00100001 00100010 00100011

20 21 22 23

32 33 34 35

SP /A /B /C

SP3 ! " #

00000100 00000101 00000110 00000111

04 05 06 07

04 05 06 07

$D $E $F $G

EOT ENQ ACK BEL

00100100 00100101 00100110 00100111

24 25 26 27

36 37 38 39

/D /E /F /G

$ % & '

00001000 00001001 00001010 00001011

08 09 0A 0B

08 09 10 11

$H $I $J $K

BS HT LF VT

00101000 00101001 00101010 00101011

28 29 2A 2B

40 41 42 43

/H /I /J /K

( ) * +

00001100 00001101 00001110 00001111

0C 0D 0E 0F

12 13 14 15

$L $M $N $O

FF CR SO SI

00101100 00101101 00101110 00101111

2C 2D 2E 2F

44 45 46 47

/L /M /N /O

, . /

00010000 00010001 00010010 00010011

10 11 12 13

16 17 18 19

$P $Q $R $S

DLE DC1 DC2 DC3

00110000 00110001 00110010 00110011

30 31 32 33

48 49 50 51

/P4 /Q /R /S

0 1 2 3

00010100 00010101 00010110 00010111

14 15 16 17

20 21 22 23

$T $U $V $W

DC4 NAK SYN ETB

00110100 00110101 00110110 00110111

34 35 36 37

52 53 54 55

/T /U /V /W

4 5 6 7

00011000 00011001 00011010 00011011

18 19 1A 1B

24 25 26 27

$X $Y $Z %A

CAN EM SUB ESC

00111000 00111001 00111010 00111011

38 39 3A 3B

56 57 58 59

/X /Y /Z %F

8 9 : ;

00011100 00011101 00011110 00011111

1C 1D 1E 1F

28 29 30 31

%B %C %D %E

FS GS RS US

00111100 00111101 00111110 00111111

3C 3D 3E 3F

60 61 62 63

%G %H %I %J

< = > ?

B-3

Page 380

TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual nugget CODE39

Full ASCII Table (continued) Binary0

Hex1

Decimal

Code 39

ASCII2

Binary0

Hex1

Decimal

Code 39

ASCII2

01000000 01000001 01000010 01000011

40 41 42 43

64 65 66 67

%V A B C

@ A B C

01100000 01100001 01100010 01100011

60 61 62 63

96 97 98 99

%W +A +B +C

` a b c

01000100 01000101 01000110 01000111

44 45 46 47

68 69 70 71

D E F G

D E F G

01100100 01100101 01100110 01100111

64 65 66 67

100 101 102 103

+D +E +F +G d e f g

01001000 01001001 01001010 01001011

48 49 4A 4B

72 73 74 75

H I J K

H I J K

01101000 01101001 01101010 01101011

68 69 6A 6B

104 105 106 107

+H +I +J +K h i j k

01001100 01001101 01001110 01001111

4C 4D 4E 4F

76 77 78 79

L M N O

L M N O

01101100 01101101 01101110 01101111

6C 6D 6E 6F

108 109 110 111

+L +M +N +O l m n o

01010000 01010001 01010010 01010011

50 51 52 53

80 81 82 83

P Q R S

P Q R S

01110000 01110001 01110010 01110011

70 71 72 73

112 113 114 115

+P +Q +R +S p q r s

01010100 01010101 01010110 01010111

54 55 56 57

84 85 86 87

T U V W

T U V W

01110100 01110101 01110110 01110111

74 75 76 77

116 117 118 119

+T +U +V +W t u v w

01011000 01011001 01011010 01011011

58 59 5A 5B

88 89 90 91

X Y Z %K

X Y Z [

01111000 01111001 01111010 01111011

78 79 7A 7B

120 121 122 123

+X +Y +Z %P x y z {

01011100 01011101 01011110 01011111

5C 5D 5E 5F

92 93 94 95

%L %M %N %O

\ ] ^ _

01111100 01111101 01111110 01111111

7C 7D 7E 7F

124 125 126 127

%Q %R %S %T5

| } ~ n6

B-4