The text of a manual · part 37 of 43
TRAKKER Antares 2455 Vehicle-Mount Terminal User's Manual, pages 361 to 370
Pages 361 to 370 of 422
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2455
Page 361
A Terminal Specifications
Page 362
Page 363
CODE39 Nugget Terminal Specifications
A
This appendix lists the terminal’s physical and environmental specifications, the serial port pin assignments, and the default configuration. This appendix also lists the configuration commands in alphabetical order by command syntax.
Physical and Environmental Specifications You can use the tables in this section to find technical information about these features and options: •
Terminal Dimensions
•
T2455 Keyboard Dimensions
•
Mounting Bracket Dimensions
•
Power Specifications
•
Electrical Specifications
•
Temperature and Environmental Specifications
•
Screen
•
T2455 Keyboard and Overlays
•
Application Options
•
Memory
•
Bar Code Symbologies
•
RF Communications
•
RF Network Support Options
•
Wired Data Communications
•
Input Devices for the Scanner Port
•
Cable Accessories
Note: For programming and file system specifications, see Chapter 5, “Using Custom Applications.” Terminal Dimensions Length:
11.2 in (28.4 cm)
Height:
6.0 in (15.2 cm)
Depth:
4.2 in (10.7 cm)
Weight:
8.9 lbs (4.04 kg)
Note: The T2455 dimensions are for the T2455 only without a keyboard.
A-3
Page 364
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
T2455 Keyboard Dimensions Length:
11.2 in (28.4 cm)
Height:
4.1 in (10.4 cm)
Depth:
1.7 in (4.3 cm)
Weight:
2.2 lbs (1.0 kg)
Mounting Bracket Dimensions Length of the base:
12.16 in (30.88 cm)
Width of the base:
2.5 in (6.35 cm)
Radius of holes on the base:
.203 in (.52 cm)
Location of holes on the base:
.5 in (1.270 cm) from edge
Power Specifications Operating (with power supply):
10V to 36 VDC or 15V to 96 VCD universal power supply
Memory Backup:
Rechargeable NiCd 700 mA battery pack
Use the measurements in this illustration to prepare a mounting location on the vehicle for the DC power supply. The low-input and high-input DC power supplies have the same dimensions. 2x ∅ .281 in .7137 cm
4.65 in 11.81 cm
4.05 in 10.29 cm
3.04 in 7.72 cm
6.08 in 15.44 cm
A-4
2455IP.007
Page 365
CODE39 Nugget Terminal Specifications
A
Electrical Specifications Model: Electrical rating:
T2455
S 12V, 4A
Temperature and Environmental Specifications Operating the terminal: Standard T2455 Cold-Temperature T2455
14°F to +122°F -22°F to +122°F
-10°C to +50°C -30°C to +50°C
Storing the terminal:
-4°F to +122°F
-20°C to +50°C
Charging the backup battery: Standard T2455 Cold-Temperature T2455
14°F to +104°F -4°F to +104°F
-10°C to +40°C -20°C to +40°C
Relative humidity:
0 to 95% non-condensing
Screen •
25 lines by 80 characters
•
CGA-compatible, backlit LCD or electroluminescent (EL)
T2455 Keyboard and Overlays •
Alphanumeric keyboard with 55 keys, 5 separate function keys, ABCD key layout
•
5 separate function keys also available on T2455 function keypad
•
Keyboard overlays available in English, Western European, IBM 3270 terminal emulation, IBM 5250 terminal emulation, and VT100/220/320 and ANSI terminal emulation
Application Options •
Programmable terminal
•
IBM 3270 terminal emulation
•
IBM 5250 terminal emulation
•
VT100/220/320 and ANSI terminal emulation
A-5
Page 366
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Memory •
2MB programmable flash memory, of which 750K is available as a flash drive for storing user applications and files
•
1MB battery-backed RAM, 512K available for user
•
Optional 4MB programmable flash memory (the extra 2MB can be configured as drive D or as storage for double-byte fonts)
•
Extended memory option for an additional 2MB or 4MB SRAM storage drive
Bar Code Symbologies •
Codabar
•
Code 93
•
Code One
•
Code 128
•
Code 11
•
Interleaved 2 of 5
•
Code 16K
•
MSI
•
Code 2 of 5
•
PDF 417
•
Code 39
•
Plessey
•
Code 49
•
UPC/EAN
RF Communications •
2.4 GHz (to 2.4835 GHz) radio (frequency range varies by country)
•
WLI Forum OpenAir™ compatible frequency hopping spread spectrum radio
•
100 mW maximum output power
•
1.6 Mbits per second data speed, 800 Kbps fallback rate for extended range
•
Coverage ≥ 500 feet (152 meters) indoors; ≥ 1,500 feet (457 meters) outdoors
•
RF network protocol options: TCP/IP or UDP Plus
RF Network Support Options •
Connectivity to a host on an Ethernet, token ring, twinaxial, coaxial, or SDLC network through an access point and DCS 300 using UDP Plus protocol
•
Connectivity to a host on an Ethernet or token ring network through an access point using TCP/IP protocol
Wired Data Communications
A-6
•
RS-232C serial ports (COM1, COM4)
•
XMODEM/YMODEM protocol for data transfer
•
Protocols: Configurable Serial Protocol, Polling Mode D, Master Polling, Binary
Page 367
CODE39 Nugget Terminal Specifications
A
Input Devices for the Scanner Port You can attach these Intermec input devices to the Scanner port: •
1517, 1518, and 1519 laser scanners
•
1550 and 1551 laser scanners
•
1552 cordless laser scanner with 9745 base station
You must use a laser scanner adapter cable to connect the input device to the Scanner port. For help, use the list in “Cable Accessories” or contact your local Intermec service representative. Cable Accessories •
151X laser scanner cable, 6 feet (Part No. 066845)
•
151X laser scanner cable, 25 feet (Part No. 067540)
•
1550 laser scanner cable, 6 feet (Part No. 067541)
•
1550 laser scanner cable, 25 feet (Part No. 067542)
•
1551 laser scanner cable, 6 feet (Part No. 067730)
•
1551 laser scanner cable, 25 feet (Part No. 067731)
•
9745 base station wand emulation cable for T2455 (Part No. 067364-016) Note: This cable does not provide an environmentally sealed connection to the T2455.
•
COM port adapter cable (Part No. 061799) for COM4 Note: This cable does not provide an environmentally sealed connection to the T2455.
•
RS-232 null-modem adapter cable (Part No. 066847)
•
Codewriter 4102 printer cable (Part No. 067642)
•
O’Neil MicroFlash3 printer cable (Part No. 067643)
A-7
Page 368
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Serial Port Pin Assignments Use these serial port pin assignments to make your own serial cables or troubleshoot problems.
Pin Assignments for Scanner, COM1, and Keyboard Ports This illustration shows the type of connector used for the Scanner port, COM1 port, and Keyboard port. The following tables list the pin assignments for each port. Pin 1
Pin 10
2455U.130
Scanner Port Pin Assignments
A-8
Pin
Description
1
+5 VDC
2
Ground
3
Trigger
4
Laser Enable/Ready to Send
5
Beeper
6
Ground
7
Video/Received
8
Start of Scan/Clear to Send
9
Good Read / Transmitted
10
Reserved
Page 369
CODE39 Nugget Terminal Specifications
A
COM1 Port Pin Assignments Pin
Description
1
Data Carrier Detect
2
Received
3
Transmitted
4
Data Terminal Ready
5
Ground
6
Data Set Ready
7
Ready to Send
8
Clear to Send
9
Reserved
10
Reserved
Keyboard Port Pin Assignments Pin
Description
1
Ground
2
Keyboard Clock
3
Reserved
4
Keyboard Data
5
Reserved
6
+5V Keyboard
7
Reserved
8
Ground
9
Reserved
10
Reserved
A-9
Page 370
TRAKKER Antares 2455 Vehicle-Mount Terminal User’s Manual CODE39 Nugget
Pin Assignments for Power Supply Port This illustration shows the Power Supply port connector and its pin assignments.
Pin 4: Chassis ground
Pin 3: -DC
Pin 2: +DC
Pin 1: Chassis ground
2455U.131
Default Configuration The next tables show the terminal’s default configuration. You can use the TRAKKER Antares 2400 Menu System to set the terminal to the default configuration. For help, see “Restoring the Terminal’s Default Configuration” in Chapter 3.
Default Configuration for Bar Code Symbologies
A-10
Parameter
Default
Codabar
Disabled
Code 11
Disabled
Code 16K
Disabled
Code 2 of 5
Disabled
Code 39
Full ASCII Code 39 enabled with no check digit
Code 49
Disabled
Code 93
Disabled
Code 128
Standard
Interleaved 2 of 5
Disabled
MSI
Disabled
Plessey
Disabled
UPC/EAN
UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A